Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 9

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  corona
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
We introduce and study the dominated edge coloring of a graph. A dominated edge coloring of a graph G, is a proper edge coloring of G such that each color class is dominated by at least one edge of G. The minimum number of colors among all dominated edge coloring is called the dominated edge chromatic number, denoted by [formula]. We obtain some properties of [formula] and compute it for specific graphs. Also examine the effects on [formula] when G is modified by operations on vertex and edge of G. Finally, we consider the k-subdivision of G and study the dominated edge chromatic number of these kind of graphs.
PL
Dynamika ruchu strugi ziaren w polu elektrycznym separatora odchylającego ma ogromne znaczenie dla prawidłowego przebiegu procesu rozdziału tych ziaren siłami elektroforezy. W pracy opisano badania nad zachowaniem się w polu elektrycznym strugi naelektryzowanych ziaren węgla.
EN
The laws of dynamics of the stream of charged particles in the electric field of the separator are essential to the correct run of electroseparation process. In this article the results of the investigations of the stream of charged carbon particles are given.
EN
This paper addresses the steady state analysis and the electromagnetic transients of overhead power transmission lines exhibiting corona. After a brief survey of the currently available modeling techniques, an alternative approach to the simulation of the corona discharge is presented. It is based on adding voltage-dependent current sources at prespecified nodes within the line’s lumped, ladder-shaped, equivalent circuit including an aduqate number of sections. The characteristics of these current sources can be determined using the usually available corona power loss measurements under power frequency sinusoidal voltage conditions. The line model is used for finding its transient response using time domain techniques. Several voltage excitation waveforms and magnitudes as well as different line’s loading conditions are investigated. As a further application of the suggested approach, the minimizion of the total corona losses of a long shunt compensated line will be considered as an additional criterion in the process of identifying the appropriate rating and location of the compensating coil primarily used for improving the line’s voltage profile.
EN
Gas insulated switchgear (GIS) is the most important equipment in the power grid. The partial discharge (PD) is the premonitory detection method for the insulation failure. The UHF detection method and acoustic detection method is the most used in filed. UHF method has excellent antiinterference performance and acoustic method has excellent defect location ability. Metal tip defect will appear on GIS for manufacturing and other reasons. The metal tip will lead to corona discharge under operating voltage. It is necessary to study the characteristics of corona discharge for fault detection and diagnosis. The experimental system is set up and the corona discharge characteristics on conductor and ground in actual GIS model are studied using above two methods. The comparing of the two methods is studied in this paper.
PL
Wyładowanie niezupełne może być metodą detekcji złej izolacji w przełącznikach gazowych GIS. Doi wykrywania wyładowania najczęściej używa się metody UHV lub akustycznej. Pierwsza z nich jest odporna na zakłócenia druga bardzo dobrze pozwala na lokalizację wyładowania. W artykule przedstawiono porównanie obu metod. (Badanie różnymi metodami wyładowania niezupełnego w przełącznikach gazowych)
PL
Losowość zjawisk ulotowych w liniach elektroenergetycznych i towarzyszącego im hałasu sprawia, że w praktyce najlepszym sposobem oceny jego uciążliwości w środowisku jest monitoring ciągły. Wówczas jednak pojawiają się problemy z automatyczną ekstrakcją wskaźników stosowanych w ocenie uciążliwości akustycznej, zwłaszcza w warunkach podwyższonych zakłóceń. Jedną z bardziej wydajnych metod filtracji zakłóceń o charakterze losowym jest metoda pomiaru widma statystycznego. W pracy pokazano praktyczną realizację estymacji wskaźników hałasu ulotu na podstawie danych ze stacji monitoringu ciągłego z wykorzystaniem pomiaru widma statystycznego. Wykazano wysoką efektywność takiego podejścia zwłaszcza kiedy sygnał akustyczny ulotu jest relatywnie słaby, a poziom zakłóceń podwyższony.
EN
Random nature of corona phenomena in power lines and accompanying them audible noise cause that the best evaluation method of the negative environmental impact is a continuous signal monitoring. Unfortunately for such procedure some problems are encountered with automated extraction of the indicators normally used for evaluation of the corona audible annoyance, especially in intensified interference conditions. One of the more efficient methods of filtering out the random interference signals is the statistic spectrum measurement method. In this work a practical realization is described for estimation of corona noise indicators, making use of the statistic spectrum measurement. High efficiency of such an approach has been shown, especially when the acoustic signal of corona process is relatively low, whereas the random interference level may be intensified.
PL
Ulot elektryczny w otoczeniu przewodów linii przesyłowych wysokich napięć wpływa na poziom przepięć docierających do stacji elektroenergetycznych. W artykule przedstawiono model ulotu elektrycznego dla analizy propagacji fal przepięciowych w liniach elektroenergetycznych oraz wyniki badań przepięć w stacji elektroenergetycznej, otrzymane przy zastosowaniu programu symulacyjnego EMTP – ATP.
EN
Corona discharges occurring in the vicinity of conductors of high voltage power lines influence the level of the overvoltage waves arriving to the power substation. The corona model was applied to analyze the propagation of overvoltage waves in high voltage power lines. The paper also comprises results of calculations of overvoltages in the substation, performed using software package a EMTP – ATP simulation software.
7
Content available Spectra of subnormal pairs
EN
In this short note we present an example related to joint spectra of subnormal pairs of bounded operators. A counterexample to the equality between Taylor's spectrum and the closure of the defect spectrum is given. This example is related to the author's modification of N Sibony's counterexample to Corona Theorem on domains that fail to be strictly pseudoconvex.
8
Content available remote On k-independent sets and (k, l)-kernels in the corona of graphs
EN
A subset S ⊆ V(G) is a k-independent set if no two of its vertices are in distance less than k. In this paper we study fc-independent sets and (k, l)-kernels (i.e. k-independent sets being l-dominating simultaneously) in the corona of graphs. We describe an arbitrary k-independent set of the corona and next we determine the Fibonacci number and the generalized Fibonacci number of the corona of special graphs. We give the necessary and sufficient conditions for the existence of (k, l)-kernels in the corona.
EN
Corona discharges occurring in the vicinity of conductors of high and extra-high-voltage power lines are one of many independent discharge forms appearing when the onset voltage level, characteristic for a given power line and resulting from its construction, is exceeded. Corona discharges are regarded as the origin of numerous unfavourable phenomena accompanying the transmission and distribution of electrical power. For example, they cause active power losses; they generate radio-electric disturbances; they influence the corrosion of conductors. On the other hand, corona discharges may influence the deformation and attenuation of overvoltage waves propagating along the overhead line conductors. Thus, if considered from the point of view of overvoltage stresses within the entire power system, the corona discharges are also a favourable phenomenon. In this paper, a corona model is presented. This model is applied to analyse the propagation of overvoltage waves in high-voltage power lines. The paper also comprises results of calculations performed using two software packages: a EMTP - ATP simulation software, and a CORONA software.
PL
Ulot elektryczny w otoczeniu przewodów linii przesyłowych wysokich i najwyższych napięć, jest jedną z form samodzielnych wyładowań niezupełnych, które pojawiają się po przekroczeniu wartości napięcia początkowego, specyficznej dla danej konstrukcji linii. Ulot elektryczny jest przyczyną wielu negatywnych zjawisk towarzyszących przesyłowi i rozdziałowi energii elektrycznych, na przykład strat mocy czynnej, zakłóceń radioelektrycznych czy korozji przewodów. Ulot elektryczny może jednak przyczyniać się do deformacji i tłumienia fal przepięciowych, których propagacja odbywa się wzdłuż przewodów linii. Jest to więc zjawisko korzystne z punktu widzenia narażeń przepięciowych układów elektroenergetycznych. W artykule przedstawiono model ulotu elektrycznego dla analizy propagacji fal przepięciowych w liniach elektroenergetycznych wysokich napięć oraz wyniki badań, otrzymane przy zastosowaniu programu symulacyjnego EMTP - ATP oraz programu CORONA.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.