Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  coordinate metrology
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents a new method of analysis of a controlled radius (CR). The presented method was verified based on simulations of coordinate measurements and during real measurements conducted on the selected coordinate measuring machine (CMM) – ACCURA II. In addition, the investigations were conducted by means of the Calypso metrology software and the Python programming environment. Computer simulations were performed for the selected dispersion of measurement points relating to nominal data of measured products. The actual coordinate measurements were conducted by using various measurement strategies. The created method takes into account the analysis of flattening of a considered curve, for which the measurement characteristic CR is determined. The analysis was conducted based on linear regression. The advantage of the presented method is the possibility of its implementation in software of a CMM and, consequently, the use of the above-mentioned method in industry. The new method detected flat fragments of measured objects regardless of the applied number of measurement points.
PL
Konferencje, kongresy i wszelkiego rodzaju sympozja organizowane w świecie rzeczywistym mają różne cele i efekty. Oprócz niezaprzeczalnych wartości naukowych wynikających z prezentowanych dokonań i świadomości, w którą stronę zmierza nauka, są też doskonałą okazją do spotkań w mniejszym gronie, wymiany doświadczeń w rozmowach kuluarowych i burzy mózgów powodującej koncepcje nowych badań i projektów. A zatem cofnijmy się do 2019 roku, kiedy nikomu jeszcze nie śniło się o pandemii, i przywołajmy wspaniałą atmosferę VIII Kongresu Metrologii, zorganizowanego w Augustowie przez Politechnikę Białostocką.
EN
Conferences, congresses and all kinds symposia organized in the real world have different goals and effects. In addition to the undeniable scientific values resulting from the presented achievements and the awareness in which direction science is heading, they are also an excellent opportunity to meet in a smaller group, exchange experiences in unofficial conversations and brainstorm the concepts of new research and projects. So let’s go back to 2019, when no one even thought that a pandemic was possible, and recall the wonderful atmosphere of the 8th Metrology Congress, organized in Augustów by the Białystok University of Technology.
EN
Reliable measurement uncertainty is a crucial part of the conformance/nonconformance decision-making process in the field of Quality Control in Manufacturing. The conventional GUM-method cannot be applied to CMM measurements primarily because of lack of an analytical relationship between the input quantities and the measurement. This paper presents calibration uncertainty analysis in commercial CMM-based Coordinate Metrology. For the case study, the hole-plate calibrated by the PTB is used as a workpiece. The paper focuses on thermo-mechanical errors which immediately affect the dimensional accuracy of manufactured parts of high-precision manufacturers. Our findings have highlighted some practical issues related to the importance of maintaining thermal equilibrium before the measurement. The authors have concluded that the thermal influence as an uncertainty contributor of CMM measurement result dominates the overall budgets for this example. The improved calibration uncertainty assessment technique considering thermal influence is described in detail for the use of a wide range of CMM users.
4
Content available remote Współpraca transgraniczna w nauczaniu metrologii współrzędnościowej
PL
Vysoká Škola Báňská – Technická Univerzita Ostrava, Fakultou Strojní oraz Laboratorium Metrologii Akademii Techniczno-Humanistycznej w Bielsku-Białej złożyły wspólny projekt dydaktyczny w ramach programu Interreg V-A Republika Czeska–Polska pt.: „Zwiększenie zatrudnienia absolwentów wyższych uczelni technicznych w praktyce”. Przedstawiono zarys projektu oraz program ćwiczeń laboratoryjnych opierających się na normach z serii ISO 10360, VDI/VDE 2617 oraz ISO 230.
EN
VSB – Technical University of Ostrava, Faculty of Mechanical Engineering together with University of Bielsko-Biala, Laboratory of Metrology submitted a proposal of common education project in the framework of the Interreg V-A Czech Republic–Poland program entitled: ‘Increasing employment of graduates of technical universities in practice’. The paper presents an outline for chosen laboratory classes based on the standards ISO 10360, VDI/VDE 2617 and ISO 230.
EN
In the paper a possibility of in-process inspection of gear and spline shafts during forming was discussed. Different methods of forming toothed elements were discussed as well as the other technologies were mentioned. Coordinate measurement technique as a way of post process inspection was presented. However, it is not possible to use it for checking features during forming process. To do it different sensors were used and their combinations were described.
PL
Artykuł przedstawia rozwój metrologii współrzędnościowej i jej wpływ na jakość i innowacyjność wytwarzania produktów w zakładach produkcyjnych w dzisiejszych czasach. Współrzędnościowe systemy pomiarowe, konstruowane dzięki rozwojowi tej nauki stanowią najbardziej zaawansowane technologicznie rozwiązania stosowane w inżynierii produkcji. Instalacja takiego systemu stanowi o wysokim poziomie innowacyjności zakładu przemysłowego. Stale wzrasta zapotrzebowanie na specjalistów z zakresu metrologii współrzędnościowej czego dowodem są laboratoria wzorcujące akredytowane w tej dziedzinie.
EN
The article presents the development of coordinate metrology – the science of measurement of spatial objects geometry - and its impact on the quality and innovation of manufacturing products in factories today. Coordinate measuring systems, constructed by the development of the science, are the most technologically advanced engineering solutions applied in production. The installation of such a system provides a high innovation of manufactured products. The need for specialists in the field of coordinate metrology is constantly increasing as seen in accredited calibration laboratories.
PL
We współczesnej diagnostyce obrazowej występuje konieczność dokonywania nieinwazyjnych pomiarów oraz przestrzennego odwzorowania kształtów i struktur stawowych z odpowiednią oraz rozpoznaną dokładnością. Ta potrzeba powoduje, że dynamiczny rozwój technik obrazowania medycznego ulega konsolidacji ze współrzędnościowymi inżynierskimi technikami pomiarowymi. W rozprawie podjęto problematykę integrującą metrologię obrazowania tomografią komputerową (CT) i tomografię rezonansu magnetycznego (MR) z metrologią współrzędnościową (CM) w celu analizy i oceny dokładności odwzorowania kształtu powierzchni stawowych biołożysk w badaniach in vivo oraz in vitro. Ocena dokładności odwzorowania kształtu powierzchni biołożysk diagnozowanych metodami CT i MR jest zagadnieniem trudnym z uwagi na rożne podstawy fizyczne obu metod diagnostycznych, różne techniki tworzenia obrazów w formacie dicom oraz udziału wielu zmiennych pomiarowych i aparaturowych wpływających na rodzaj obróbki, techniki prezentacji i analizy obrazu. Kształty stawów biodrowych, kolanowych i skokowych odwzorowywano z wykorzystaniem diagnostycznej i pomiarowej aparatury współrzędnościowej na podstawie przeprowadzonych badań klinicznych i na podstawie badań preparatów kadawerskich w procedurze bezpośredniej oraz z zastosowaniem modeli negatywowych. Przeprowadzone przez autora badania pozwoliły na zapis kształtu powierzchni nieregularnych, zwłaszcza przy zmiennej krzywiźnie, z dokładnością wymaganą przez proces oceny geometrii oraz porównanie ich z elementami referencyjnymi. Zastosowanie techniki współrzędnościowej do analizy kształtu wzorców przestrzennych pozwoliło odpowiedzieć na pytania: Czy w dostępnych technikach obrazowania można ocenić błąd odwzorowania kształtu? Czy w zaawansowanych badaniach obrazowych występują błędy odwzorowania kształtu wpływające na podjęcie diagnozy i w jakich obszarach należy się liczyć z możliwością występowania takich błędów? Czy można wykryć zmiany w początkowym stadium choroby zwyrodnieniowej stawów (chzs) i z odpowiednią dokładnością je zlokalizować? Nieinwazyjne techniki diagnostyczne CT i MR do obrazowania biołożysk powinny stanowić metody z wyboru do szczegółowej i globalnej identyfikacji kształtu struktur kostnych i chrzęstnych stawów, ich wzajemnego usytuowania i zmian patomorfologicznych. Zastosowanie współrzędnościowej techniki pomiarowej z wykorzystaniem modeli negatywowych uzyskanych z preparatów kadawerskich pozwoliło na wyznaczenie modeli referencyjnych w stosunku do obiektów wyznaczonych na podstawie sekwencyjnej i spiralnej CT oraz na podstawie MR. Metoda modeli negatywowych stanowi obiektywne narzędzie przy ocenie jakości odwzorowania kształtów. Opracowanie procedury umożliwiającej izomorficzną segmentację obrazów zapisanych w formacie dicom oraz przestrzenną rekonstrukcję obrazów zapewniło odpowiednie warunki oceny funkcjonowania tomografów dla potrzeb odwzorowania kształtów powierzchni stawowych. Sprawdzenie dokładności obrazowania i odwzorowania w nieinwazyjnej metodzie MR w przypadku niewielkich ubytków chrząstki i chondromalacji może służyć w planowaniu i po zabiegowym monitorowaniu terapii transplantacyjnych. Wykonane w rozprawie badania i eksperymenty pozwoliły poszerzyć wiedzę na temat dokładności odwzorowania kształtu elementów biołożysk. Dają możliwość poprawy techniki diagnozowania i terapii choroby zwyrodnieniowej stawów. Szczególnie istotne znaczenie analizowanych zagadnień można wskazać i wykorzystać w procedurach klinicznych realizowanych z zastosowaniem robotów, systemów nawigacji komputerowej, systemów komputerowego wspomagania i wykonania endoprotez oraz systemów telemedycyny. Równocześnie stanowią one przesłanki do dalszych badań dotyczących oceny dokładności odwzorowania przestrzennego szpary stawowej w warunkach obrazowania dynamicznego z wykorzystaniem fuzji obrazów CT i MR.
EN
At the current level of advancement of diagnostic methods in orthopedics, traumatology and prosthetics, it is necessary to carry out non-invasive measurements and spatial mapping of shapes and structures of joint structures with appropriate and known accuracy. This need causes that the rapid development of medical imaging teclmiques is becoming consolidated with coordinate measuring techniques. This dissertation discusses problems that integrate methodology of computed tomography (CT) imaging and magnetic resonance tomography (MR) with coordinate metrology (CM) in order to analyze and evaluate the accuracy of shape mapping of biobearing surfaces in in vivo and in vitro analysis. Accuracy assessment of biobearings surfaces shape mapping diagnosed by CT and MR methods is a difficult task, mainly because of the physical basis of these two diagnostic methods, different techniques for creating dicom format images and contribution of many measuring and appliance variables aflecting the type of processing, presentation techniques and image analysis. Shapes of hip, knee and ankle joints were mapped using diagnostic and coordinate measuring devices basing on performed clinical studies and tests of specimen in direct procedure and using negative models. Experiments carried out by the author allowed registration of the shape of irregular surfaces, especially those with variable curvature, with the accuracy required by the process of geometry evaluation and their comparison with reference elements. Use of the coordinate measuring technique for the analysis of spatial standards shape allowed to answer the following questions: Do the available imaging techniques allow shape mapping error assessment? Are advanced imaging studies aflected by shape mapping errors that influence making of the diagnosis and in which areas should those kind of errors be expected? Is it possible to detect changes in the early stages of osteoarthritis (OA) and locate them with sufficient accuracy? Non-invasive diagnostic techniques CT and MR used for imaging of biobearings should be the methods of choice for the identification of specific and global shape identification of the bone and cartilage structure of joints, their relative location and pathological changes. Use of the coordinate measuring technique using negative models obtained from the specimen allowed to determine the reference model in relation to objects constructed using sequential and spiral CT, and on the basis of MR. The negative models method represents an objective tool for assessing the quality of shape mapping. Development of procedure of an isomorphic segmentation of images recorded in dicom format and spatial image reconstruction provided the right conditions for CT functioning assessment for shape mapping purposes. Checking of the accuracy of imaging and non-invasive mapping on MR in case of small cartilage defects, and chondromalacia can be used in the planning and monitoring of surgical transplantation therapy. Research and experimentation performed in the framework of this dissertation allowed to broaden the knowledge about the accuracy of shape mapping of the elements of the biobearing. It offers an opportunity to improve diagnosing techniques and treatment of osteoarthritis. Particular importance of the issues being discussed here can be identified and used in clinical procedures performed with the use of robots, computer navigation systems, computer-aided systems, construction of implants and telemedicine systems. At the same time, they provide grounds for further research on the assessment of the accuracy of spatial mapping in a joint space in dynamic imaging conditions using a fusion of CT and MR.
PL
W wyniku pomiarów współrzędnościowych powierzchni swobodnych otrzymuje się dane o charakterze przestrzennym. Odchyłki zdeterminowane są przestrzennie skorelowane, brak autokorelacji przestrzennej oznacza losowość odchyłek. Odmienna natura odchyłek geometrycznych jest w opisanej metodyce podstawą usuwania składowej losowej z danych pomiarowych.
EN
Presented is a method of modeling a surface representing determined deviations, which requires that the random component should be rejected. Used in this work were regression analysis, interactive procedure, NURBS modeling and three dimensional statistical analysis.
PL
Przedstawiono metodę oceny odwzorowania geometrii przedmiotu mierzonego za pomocą współrzędnościowego ramienia pomiarowego (WRP) z optyczną głowicą skanującą. Obiektem badań był korpus silnika wcześniej wywzorcowany na WMP o wysokiej precyzji. Przeprowadzone badania umożliwiły wyznaczenie dokładności WRP poprzez ocenę odwzorowania kształtu za pomocą dwóch różnych urządzeń, z czego jedno jest o ponad rząd wielkości dokładniejsze od drugiego.
EN
Presented is a method of appraisal of geometric accuracy of an object when the measurements are carried out by means of the coordinate measuring arm (CMM) with optical scanning head. Subjected to testing was an engine block which had been calibrated before on a coordinate measuring machine of high precision standard. The tests made it possible to determine accuracy standard through comparison of the models created by two machines from which one is of higher measuring accuracy standard than the other by one order of magnitude.
PL
W artykule opisano problematykę oceny dokładności pomiarów realizowanych przy zastosowaniu współrzędnościowych systemów pomiarowych. Przedstawiono metody wyznaczania niepewności pomiaru oraz problem relacji pomiędzy dokładnością urządzeń i systemów pomiarowych a dokładnością pomiaru. Opisano też metody wykorzystujące koncepcję modeli symulacyjnych - wirtualnych maszyn pomiarowych jako skutecznych narzędzi szacowania niepewności pomiarów.
EN
This article presents the problems of estimating the accuracy of measurements made by using coordinate measuring machines. The methods of estimating the uncertainty of measurements and issues concerning the relation between the accuracy of instruments and measuring systems and the accuracy of measurement are described. Methods based on the concept of simulation models (Virtual Measuring Machines) as effective tools for estimation of measurement uncertainty are also described.
PL
W artykule zaprezentowano problematykę oceny dokładności pomiarów realizowanych przy zastosowaniu współrzędnościowych systemów pomiarówych. Przedstawiono metody wyznaczania niepewności pomiaru oraz problem relacji pomiędzy dokładnością urządzeń i systemów pomiarowych a dokładnością pomiaru. Opisano też metody wykorzystujące koncepcję moedeli symulacyjnych - wirtualnych maszyn pomiarowych jako skutecznych narzędzi oceny on-line szacowania niepewności pomiarów.
EN
This article presents the problems of estimating the accuracy of measurements made by using coordinate measuring machines. The methods of estimating the uncertainty of measurements and issues concerning the relation between the accuracy of instruments and measuring systems and the accuracy of measurement are described. Methods based on the concept of simulation models (Virtual Measuring Machines) as effective tools for on-line estimation of measurement uncertainty are also described.
12
Content available remote Rozwój metrologii współrzędnościowej w systemach zapewnienia jakości
PL
Stosowanie maszyn współrzędnościowych w polskim przemyśle ma już dwudziestokilkuletnią tradycję. Współczesne systemy zapewnienia jakości oparte o wymogi ISO 9000:2000, szczególną rolę w systemie przypisują kontroli i nadzorowaniu narzędzi pomiarowych. Jednym z najpoważniejszych problemów, jakie napotykają użytkownicy maszyn współrzędnościowych (WMP), jest ich okresowa kontrola. Od wprowadzenia z początkiem lat 80 ubiegłego wieku zaleceń CMMA rozwój metrologii współrzędnościowej w zakresie opracowania nowych metod kalibracji, sprawdzania okresowego wprowadził wiele zmian. Najczęściej stosowana jest tutaj metoda oparta o kontrolny pomiar długości. Z uwagi na konieczność opracowania metod oceny dokładności pomiarów realizowanych przy pomocy WMP, normy i zalecenia oparte o kontrolny pomiar długości stają się niewystarczające. Trwają więc prace nad opracowaniem bardziej adekwatnych koncepcji i metod spełniających wymogi metrologii współrzędnościowej. Przykładem są tu opisane w artykule zarówno Metoda Macierzowa jak i Laserowy Wzorzec Stopniowy, opracowane w Katedrze Inżynierii Procesów Produkcyjnych Politechniki Krakowskiej.
EN
Tradition of using of CMM in Poland is twenty years old. New quality systems based on ISO 9000:2000 guidelines, points out of control and measurement device supervision. One of the most important problems of users of Coordinate Measuring Machines (CMM) is recertification tests. Since introduce in beginning of 80-years guideline CMMA development of coordinate metrology on new methods of calibration and recertification tests make many changes. Generally is used a method based on control length measurement. These methods are not sufficient for uncertainty assessment others coordinate measuring tasks. The research of more adequate methods and ideas for filling out requirements of CMM metrology are still developed. Examples of this: Matrix Method and Laser Gauge Step are described in this article.
EN
The paper presents an issue of curvilinear profile measurements. A complex approach to this problem requires that geometrical element description including its accuracy is to be dealt with. Applied measurement equipment and proposed calculation algorithms enable that measured profiles data will be obtained with a specified accuracy. A CAD-CAM-CAQ link was presented basing on an arbitrary profile measurement.
PL
W pracy przedstawiono zagadnienie pomiaru zarysu krzywoliniowego. Złożoność zagadnienia wymaga wspólnego opisu geometrii elementów i jej dokładności. Wykorzystane narzędzie pomiarowe oraz zastosowane algorytmy obliczeń pozwalają na otrzymanie wyników pomiarów oraz określenie dokładności otrzymanych rezultataów. Połączenia CAD-CAM-CAQ jest przedsatwione dla pomiaru dowolnego zarysu krzywoliniowego.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.