Roller blinds are devices that are retracted and wrapped in a box above the window opening and are used to protect against the solar radiation. Those are the well-known devices with distinct advantages over the fixed external dimming elements. The influence of external blinds on the internal thermal environment in climatic conditions in the Republic of Serbia, the city of Kragujevac, was considered in this research. An external blind was installed in the test room and its influence on the internal temperature was compared with the internal temperature of the room without the blind. Real-time monitoring was carried out in February and August 2023. The results presented in this paper show that the blind reduces the temperature in summer by 3.57ºC and increases it in winter by 1.76ºC. The cooling load can be reduced by about 20%, and the heat load by about 15%.
EN
Solar control devices have a significant effect on providing indoor thermal comfort by minimizing annual energy costs in hot-dry climates. Within the scope of the study, the settlement pattern Şilbe 1st Stage Mass Housing settlement located in the city of Diyarbakır, which is located in the hot dry climate zone, was discussed. Horizontal-vertical solar control devices were placed on the transparent surfaces in east-west and northeast-southwest directions, which give optimum results due to the shadow effect, by means of the DesignBuilder Simulation Programme, and the effect of annual heating and cooling energy load expenses was examined.This study aimed to examine the effect of solar control devices on energy saving in hot dry climate regions.As a result of the study, solar control devices placed in both east and west directions provided a significant decrease in annual energy costs. In addition, the types of solar control devices (horizontal or vertical) used had an impact on annual energy costs. As a result of the analysis, it was determined that horizontal solar control devices should be preferred in hot-dry climate regions. This study will be a guide for the studies carried out within the scope of energy efficient structure design of solar control devices.
PL
W Polsce brakuje danych dotyczących zapotrzebowania na energię niezbędną do utrzymania systemów wentylacyjnych, grzewczych i chłodniczych. Duże wartości strumieni powietrza wentylującego, wysokie wymagania dotyczące jakości oraz parametrów cieplno-wilgotnościowych powietrza w obiektach szpitalnych i służby zdrowia wpływają na wysokie koszty ich utrzymania. W dobie kryzysu politycznego, energetycznego oraz globalnie zmieniającego się klimatu, każda metoda ograniczania energii niezbędnej do transportu i uzdatniania powietrza musi być rozważona i uwzględniona zarówno w procesie projektowym, remontowo-modernizacyjnym jak i w codziennej eksploatacji budynków. Celem artykułu było wykazanie w jakim stopniu można ograniczyć roczne zapotrzebowanie na energię określone dla 1 m3/s powietrza zarówno w aspekcie jego transportu jak i uzdatniania. Takie jednostkowe określenie energii jest niezależnym wskaźnikiem, który można wykorzystać do każdej wartości strumienia powietrza wentylującego. Do wyznaczenia rocznego zapotrzebowania na energię niezbędną do uzdatniania powietrza przygotowano wykresy t-tz obrazujące roczny cykl pracy urządzenia wentylacyjnego z odzyskiem ciepła z wymiennikiem o sprawności 50% i 80%. Przyjęto 10 różnych profili sterowania pracą urządzeń. Do wyznaczenia możliwości ograniczenia energii niezbędnej do transportu powietrza wykonano obliczenia dla wentylatorów o mocy właściwej określonej zgodnie z Warunkami Technicznymi. W artykule wykazano, że zapotrzebowanie na energię do uzdatniania powietrza jest ściśle zależne od właściwie przyjętej metody sterowania pracą urządzenia oraz przyjętych wartości temperatury powietrza nawiewanego i/lub w pomieszczeniu. Przedstawiono tu także możliwe scenariusze ograniczenia strumienia powietrza wentylującego w wypadku pomieszczeń nieużytkowanych, w których należy zachować przepływ powietrza przez pomieszczenie. Wskazano także konieczność dostosowania cech architektoniczno-budowlanych budynku do maksymalnego ograniczenia zysków i strat ciepła pomieszczeń.
EN
Poland has no data concerning the energy demand to maintain ventilation, heating, and cooling systems. High values of mechanical ventilation and air-conditioning air flow and high requirements regarding indoor air quality, temperature, and relative humidity in hospital and healthcare facilities result in high maintenance costs. In the time of political and energy crisis and the globally changing climate, any method of reducing the energy demand for transport and air treatment must be considered and included in the design, renovation, and modernisation process as well as in the daily operation of buildings. The aim of the article is to show how to limit the annual energy demand, specified for 1m3/s of airflow volume, both in terms of its transport and treatment. This unitary determination of energy can be an independent indicator that can be used for each value of the ventilation air flow. To determine the annual energy demand for air treatment, t-tz charts were prepared. They show the annual operation cycle of a ventilation unit with heat recovery, with a 50% and 80% efficiency, exchanger. 10 different ventilation system control profiles have been analysed. In order to determine the possibility of reducing the energy demand for air transport, calculations were made for fans with a specific power determined in accordance with the Technical Conditions. The article shows that the energy demand for air heating and cooling is strictly dependent on the properly adopted method of controlling the operation of the device and the assumed values of supply and indoor air temperature. It also presents possible scenarios of limiting the energy demand for air transport with respect to unused rooms, where air flow through the room should be maintained. It was also indicated the need to adjust the architectural and construction features of the building to minimise the heating and cooling loads for the rooms.
PL
Wycofana norma PN-EN ISO 13790 została zastąpiona normą PN-EN ISO 52016, która określa wiele metod obliczeniowych zapotrzebowania na energię budynków do ich ogrzewania, chłodzenia, nawilżania i odwilżania powietrza wewnętrznego, obliczania bilansu energii i wyznaczania temperatury wewnętrznej w budynkach oraz wyznaczania zapotrzebowania na moc ogrzewania i chłodzenia. W artykule opisano metody obliczeniowe zawarte w tej normie oraz omówiono związki pomiędzy tą normą i normą PN-EN ISO 52017 oraz innymi powołanymi normami. W artykule przedstawiono również różnice metod obliczeniowych wycofanej normy PN-EN ISO 13790 i normy omawianej w artykule.
EN
The with drawn PN-EN ISO 13790 standard has been replaced by the PN-EN ISO 52016 standard, which contains a number of calculation methods for energy demand of buildings for heating, cooling, humidifying and dehumidifying indoor air, calculating the energy balance and determining the indoor temperature in buildings and determining the heating and cooling loads. The article describes the calculation methods contained in this standard and discusses the relationship between this standard and the PN-EN ISO 52017 standard and other referenced standards. The article also presents the differences in the calculation methods of the withdrawn PN-EN ISO 13790 standard and the standard discussed in this work.
Logistyka
|
2015
|
nr 3
4093--4100, CD 1
PL
W artykule przedstawiono analizę obciążeń chłodniczych budynku przy uwzględnieniu zmienności czynników wpływających na wielkość zysków ciepła. W celu zminimalizowania zapotrzebowania na chłód określono wpływ elementów zacieniających instalowanych po stronie zewnętrznej na oknach na wielkość mocy chłodniczej niezbędnej do klimatyzacji wybranego budynku. Wielowariantowe obliczenia obciążenia chłodniczego budynku mają na celu określenie wielkości redukcji zapotrzebowania na chłód. Określenie zysków ciepła od nasłonecznienia jest pracochłonne, lecz daje wynik odzwierciadlający wpływ powierzchni przegród przezroczystych, zastosowanych urządzeń przeciwsłonecznych oraz usytuowania budynku względem stron świata, na wewnętrzne zyski ciepła. W niniejszej pracy, wchodzące w skład bilansu zyski ciepła od nasłonecznienia określone są w trzech wariantach zacienienia okien. Aby ograniczyć zużycie anergii elektrycznej w instalacji chłodniczej określono wariant najmniejszego zapotrzebowania na energie potrzebną do funkcjonowania układu chłodzenia. Oszacowano również korzyści wynikające z czasowego niedotrzymania warunków komfortu cieplnego.
EN
The article presents an analysis of the building cooling load taking into account the variability of the factors affecting the size of the heat gains. In order to minimize the demand for cooling, the effect of shading elements installed on the outside on the windows and its effect on size of the cooling capacity of air conditioning system for the building has been estimated. Multivariate building cooling load calculations to determine the size of the reduction in cooling demand has derived. Determination of heat gain from the sun is laborious, but gives a result which reflects the influence of the surface transparent partitions, devices used as sunscreen and its location on the building envelope in relation to the world, as well as to the internal heat gains has great attention in obtained calculation. In this study, included in the balance sheet of solar heat gains are defined in three different shading of windows. To reduce the consumption of electricity energy in the cooling system of the smallest variant identified the need for the power supply for the operation of the cooling system. Also assessed the financial benefits of the temporary default of comfort.