EN
Measuring instruments, measurement methods, and an exemplary analysis of the impact of chosen operating stages of the converter drive on the power supply network have been presented. The measurements of electrical and mechanical parameters in drive systems used in industry are complex. The task is difficult due to the necessity of connecting a measuring instrument into electric circuits of an active facility with the use of only short non-operational periods of the device. However, a wellchosen model of a drive system allows the multivariate research of the impact of drive parameters and a control algorithm used on voltage and current harmonic content and performance of the system, and therefore on a simulation analysis of the impact of the drive on the power supply network.
PL
W artykule przedstawiono ocenę oddziaływania przemienników częstotliwości na jakość energii w sieci zasilającej. Oceny dokonano na podstawie pomiarów parametrów napięcia zasilającego, przeprowadzonych w rzeczywistej sieci o napięciu znamionowym 6 kV, do której zostały przyłączone napędy dużej mocy z przemiennikami częstotliwości. Wyznaczone parametry jakościowe porównano z obowiązującymi limitami. W artykule przedstawiono wybrane wyniki pomiarów oraz ich analizę i wnioski.
EN
In the paper the assessment of influence of frequency converters on power quality in the supplying network is presented. The assessment was made on the basis of voltage monitoring in real 6 kV network with high power frequency converter drives. Power quality indices determined from measurements were compared with their limits. Selected results of measurements as well as their analysis and conclusions are presented in the paper.
PL
W artykule przedstawiono ocenę oddziaływania układów napędowych z przemiennikami częstotliwości na jakość energii elektrycznej w sieci elektrycznego układu potrzeb własnych (EUPW) bloku energetycznego 50+. Oceny dokonano na podstawie badań symulacyjnych. Zaprezentowano sposób odwzorowania układu napędowego oraz założenia przyjęte od określenia mocy obciążenia jednej sekcji rozdzielni EUPW. Przedstawiono wyniki badań symulacyjnych oraz wartości wskaźników, na podstawie których dokonano oceny jakości energii w rozdzielni EUPW.
EN
The assessment of influence of frequency converter drives on power quality in ancillary services network (ASN) of power unit 50+ is presented in the paper. The assessment was made on the basis of simulation. The way of modeling of converter drives is shown and assumptions for determination of load connected to ASN is discussed. Simulation results are presented as well as power quality indices, on the basis of which the assessment of power quality in ASN was done.
PL
Prosta konstrukcja silników asynchronicznych klatkowych i związane z tym stosunkowo niskie koszty ich wytwarzania i eksploatacji były czynnikiem sprzyjającym szerokiemu ich rozpowszechnieniu w przemyśle i gospodarce komunalnej. W parze z prostotą konstrukcji tych silników nie szły jednak możliwości regulacji prędkości obrotowej, wymaganej w większości procesów technologicznych.
PL
W artykule omówiono główne przyczyny występowania w przemysłowych sieciach elektroenergetycznych odkształconych od sinusoidalnych przebiegów napięcia i prądu oraz przyczyny występowania przesunięcia fazowego między nimi. Przeanalizowano efekty obecności w takich sieciach baterii kondensatorów i pasywnych filtrów wyższych harmonicznych. Przedstawiono wyniki badań laboratoryjnych przebiegów napięcia i prądu w sieciach wyposażonych w aktywne filtry mocy. Sformułowano wnioski dotyczące efektywności stosowania poszczególnych urządzeń.
EN
The article discusses major reasons why there are voltage and current distortions of non-sinusoidal nature in industrial electrical power grids, along with the phase shift. The effects of the applied condenser batteries and passive harmonic filters were analyzed. The results of laboratory tests were presented with respect to voltage and current runs in grids equipped with active power filters. There were conclusions drawn on the efficiency of using particular devices.
EN
The paper deals with requirements that have to be met in design and modernization of electric converter drives. Technical issues connected with compensation of the reactive power and filtering of higher harmonice of the current, occurring during implementation and operation of the drives, are described using selected examples. One of the problems is increase of the voltage distortion at buses of a medium voltage switching station due to mismatch between the LC filter parameters and the current harmonic spectrum after replacing controlled DC drives of the bar rolling mill with squirrel cage motors with frequency converters. Negative effect of the idle run current compensation circuit of a new dry transformer on valve switching in the controlled rectifier after replacing old oil transformers is also described. Diagrams of supply circuits, waveforms of currents and voltages as well as harmonic spectra illustrating discussed problems are presented and conclusions and recommendations are formulated.
7
EN
The paper presents a method for estimation of converter drive parameters. This estimation encompassed three types of drives, i.e. a static Scherbius drive, a driver with a brushless direct current (BLDC) motor and a drive with a voltage inverter. For drive modelling and parameter estimation, the author implemented original program mes written in FORTRAN. As well as these, the paper describes an objective function applied for the estimation. The author also compares gradient and gradientless methods, chich are applied for minimization of the objective function. Finally, the author explains the estimation results for example drives, focusing on the coincidence of theoretical and empirical waveforms. The abovementioned procedure led to the general rule, which facilitates estimation efficiency.
PL
W artykule przedstawiono wyniki pomiarów zaburzeń elektromagnetycznych przewodzonych przeprowadzonych w dwóch rodzajach napędów przekształtnikowych. Pierwszym układem była pięciofazowa przetwornica typu step-down zasilająca silnik szeregowy prądu stałego, natomiast drugi układ był napędem falownikowym z silnikiem indukcyjnym klatkowym. Podczas badań zastosowano trójfazową sieć sztuczną typu NSLK 8126 i analizator widma Advantest R3131A. Zamieszczono także wyniki widm elektromagnetycznych zaburzeń przewodzonych dla różnych konfiguracji pracy badanych układów, które pracowały z typowym filtrem sieciowym EMI lub bez filtru. Pomimo że poziom zaburzeń przewodzonych nie przekłada się bezpośrednio na emisję zaburzeń promieniowanych, to tego rodzaju test może być podstawą do wyznaczenia poziomu zaburzeń promieniowanych, a także doboru filtru.
EN
The article presents results of measurements of electromagnetic conducted interferences for two kinds of converter drives. The measurements were carried out with three phase artificial network type NSLK 8126 and spectrum analyzer type Advantest R3131A. Presented spectrum of electromagnetic conducted interferences are for different configurations of tested circuits, with and without typical EMI filter. Although the levels of conducted interference do not translate directly into the emitted field, the tests can be used as a basis for both the evaluation of interference and the selection of filters.