This paper present the simulation of the transfer of electromagnetic disturbances from the primary to the secondary circuits of current transformers in CM-CM coupling in the frequency range [0.1 - 20MHz] . The primary voltage U1 of the primary winding equal to 30V was taken for the study of the two models of the current transformers in different configurations with and without screen to see its influence on the transmission of the disturbances, also to see the effect of capacitive couplings between the different CT elements. The simulation results obtained which represent the variation of the transfer function as a function of frequency gave us the maximum disturbance rate for each case.
PL
W artykule analizowano przejście zakłóceń elektromagnetycznych z uzwojenia pierwotnego do wtórnego przekładnika prądowego w zakresie częstotliwości 0.1 – 20 MHz. Analizowano też sprzężenie pojemnościowe między tymi uzwojeniami. Transmisja zakłóceń zależy od czestotliwości.
PL
W pracy zajęto się dostosowywaniem emisji zaburzeń elektromagnetycznych generowanych przez urządzenia elektryczne do wymagań normatywnych w zakresie kompatybilności elektromagnetycznej (EMC). Obiektem badań była oprawa oświetleniowa ze źródłami LED. Opisano zastosowane w praktyce metody redukcji emisji elektromagnetycznych zaburzeń przewodzonych i promieniowanych.
EN
The work involved adjustment of the emission of electromagnetic disturbances generated by electrical devices to the standard requirements in the field of electromagnetic compatibility (EMC). The research object was a lighting fixture with LED sources. Practical methods of emission reduction of electromagnetic conductive and radiated disturbances have been described.
PL
W artykule zaproponowano zastosowanie dwóch parametrów: procentowego błędu całkowitego transformacji wyższych harmonicznych oraz procentowego błędu całkowitego transformacji harmonicznej, do oceny dokładności transformacji harmonicznych zaburzeń przewodzonych przez przekładniki prądowe. Wykorzystanie różnicowo wyznaczanego błędu całkowitego zapewnia, przy zachowaniu niskich kosztów układu pomiarowego, wysoką dokładność wyników, pozwalając jednocześnie na ocenę właściwości metrologicznych dla poszczególnych harmonicznych oraz łącznie dla wszystkich wyższych harmonicznych zawartych w transformowanym przez badany przekładnik sygnale.
EN
In this paper the concept is discussed for evaluation of accuracy of conductive disturbances transformation by inductive currents transformers based on two developed parameters: the percentage composite error of higher harmonics transformation and the percentage composite error of harmonic transformation. The usage of coefficients calculated from measured differentially composite error ensures high accuracy of obtained results, at low costs of required measuring apparatus.
4
Content available remote Floating ground - the path for conductive disturbances in active filter circuit
PL
W artykule przedstawiono wyniki pomiarów parametrów elektrycznych zaprojektowanego i wykonanego aktywnego filtru pasmowoprzepustowego z wielokrotną pętlą sprzężenia zwrotnego. Szczegółowo opisany został problem sprzężenia zaburzeń przewodzonych poprzez ścieżkę masy z wejściem zastosowanych wzmacniaczy operacyjnych powodujący błędne działanie filtru. Ograniczenie zakłóceń w pracy układu jest możliwe przez zmniejszenie pojemności sprzęgających lub/i zapewnienie odpowiedniego uziemienia.
EN
In the paper the results of measurements of the electrical properties of the multiple feedback band-pass filter are presented. The problem of conductive disturbances coupling by the grounding path with the input of the operational amplifiers is described in detail. The interferences in operation of the circuit may be reduced by decreasing the coupling capacitances and/or ensure proper grounding.
PL
Wartości skuteczne i średnie prądów odkształconych mierzone po stronie wtórnej przekładnika prądowego są wyznaczane z błędem większym niż wynikający z klasy dokładności przekładnika określanej dla przebiegów sinusoidalnych. Wzrost stopnia odkształcenia transformowanych przez przekładnik przebiegów powoduje wzrost dodatkowego błędu transformacji odkształconego prądu. Zjawisko to może zostać wykorzystane do oceny zawartości harmonicznych w prądzie na podstawie pomiaru wartości skutecznej różnicy prądów pierwotnego i wtórnego przekładnika.
EN
RMS and average values of distorted currents measured on the secondary side of the current transformer are designated with an additional error than resulting from the accuracy of the instrument transformer designated for sinusoidal current which frequency is 50 Hz. The increase of the transferred current distortion cause increase of the additional transformation error. This phenomenon can be used to assess the current total harmonic distortion by measuring the RMS value of the difference between primary and secondary currents of the current transformer.
PL
W dotychczasowych opracowaniach normatywnych dotyczących indukcyjnych przekładników napięciowych i prądowych, a także kombinowanych brak jest wytycznych dotyczących wymagań i sposobu badania dokładności przetwarzania sygnałów odkształconych. Badanie to wymaga odpowiedniego układu do generacji sygnału testowego, który musi zapewniać między innymi stałe przesunięcie fazowe między podstawową harmoniczną przebiegu a harmonicznymi wprowadzanych zaburzeń.
EN
In standards concerning inductive voltage and current transformers, as well as combined transformers, there are no guidance on the requirements how to test the accuracy of distorted signals transfer. Test conditions requires an appropriate system for the generation of the test signal, which must ensure, among other things, a stable phase shift between the fundamental harmonic and the conductive disturbance harmonics of the instrument transformer primary signal.
PL
Jednym z podstawowych parametrów określających właściwości metrologiczne przekładników prądowych jest ich klasa dokładności uwarunkowana odpowiednimi wartościami granicznych błędów prądowych i kątowych określonych w normie [6]. Zakłócenia przewodzone pojawiające się w prądzie pierwotnym przekładnika prądowego mogą prowadzić do pogorszenia jego właściwości metrologicznych i przekroczenia dopuszczalnych granicznych wartości tych błędów. Przedmiotem artykułu są zagadnienia związane z wpływem zakłóceń przewodzonych o częstotliwościach z zakresu 200-9000 Hz na wartość błędu prądowego badanych przekładników prądowych z rdzeniem toroidalnym. Badania laboratoryjne zostały przeprowadzone dla trzech modeli przekładników prądowych klasy 0,5 o identycznych przekładniach prądowych oraz czynnych przekrojach rdzeni, jednak wykonanych z różnych materiałów magnetycznych. W artykule przedstawione zostały wyniki przeprowadzonych badań laboratoryjnych oraz wnioski z ich analizy.
EN
Operating conditions of the configuration of the windings and magnetic circuit of the current transformer during measurements of the non-sinusoidal currents are changed by the conductive disturbance. This results in deterioration of the current transformer metrological properties, which is mainly an effect of the change of its parameters of the magnetic circuit caused by higher harmonic of measured current. Disturbances in the primary current causes additional measuring errors of the current transformer which also in this conditions must not exceed limits set for a particular current transformer class [6]. Especially this is significant during calculation of the power consumption. Preserving of given accuracy class by the current transformer during measurements of the non-sinusoidal currents is required also to ensure proper accuracy of determine of the power quality [5]. Most advantageous properties under condition of stability of metrological characteristics in the function of frequency of the conductive disturbances during this measurements has current transformer with toroidal core collapsed from permalloy NiFe 78 and electrical steel ET4.
PL
Główny wpływ na właściwości metrologiczne przekładników napięciowych mają właściwości magnetyczne rdzenia oraz parametry konstrukcyjne uzwojeń. Przedmiot artykułu stanowi analiza wpływu parametrów konstrukcyjnych uzwojeń przekładników napięciowych z rdzeniem ramkowym wykonanym ze stali elektrotechnicznej ET4 na transfer zakłóceń przewodzonych. Do strony pierwotnej badanych modeli przekładników napięciowych przykładano napięcie o częstotliwości sieciowej i zadanym udziale wyższej harmonicznej o częstotliwości z przedziału 200-9000 Hz. Wyznaczano wartość danej harmonicznej napięcia zakłócającego przed i po transferze przez modele przekładników napięciowych o różnych parametrach konstrukcyjnych uzwojeń. Otrzymane wyniki pozwoliły na obliczenie współczynników transferu poszczególnych harmonicznych zakłóceń przy różnych wartościach napięcia zasilającego oraz obciążenia uzwojeń wtórnych. Badania te mają na celu opracowanie najkorzystniejszej konstrukcji prze-kładnika napięciowego pod względem dokładności transferu napięć odkształconych lub harmonicznej o określonej częstotliwości, co umożliwi wierniejszą ocenę jakości energii elektrycznej dostarczanej do odbiorników [1]. Zapewnienie odpowiedniej jakości napięcia zasilającego jest jednym z podstawowych warunków poprawnej pracy urządzeń elektrycznych [2]. Zgodnie z zaleceniami normatywnymi prowadzona jest kontrola jakości napięcia do 40. harmonicznej, tzn. częstotliwości 2000 Hz. Występują jednak urządzenia monitorujące parametry napięcia do częstotliwości 5000 Hz (np.: miernik mocy WT1600 firmy Yokogawa) [3]. Ze względu na tendencje rozwojowe w omawianej dziedzinie, przeprowadzone badania dotyczące transferu zakłóceń przez przekładniki napięciowe zostały rozszerzone do częstotliwości 9000 Hz.
EN
Construction parameters of the windings of the voltage transformers have meaningful role on transfer of conductive disturbances. Medium-voltage transformer model characterized by larger impedances and smaller capacities of its windings but with metrological properties compatible with corresponding accuracy class is describe by smaller influence of the change of the rms value of the supply voltage on the factor of the particular harmonic transfer. Moreover this voltage transformer has most linear course of this factor for tested frequencies and load of the secondary winding 6,25 VA with the change of the primary voltage in range from 40% to 100% of the rated value. However, increase of the supply voltage to 120% of rated primary voltage and load of the secondary winding as well, results in significant increase of nonlinearity of the course of the factor of particular harmonic transfer for tested frequencies. Therefore voltage transformers with construction of windings discussed in the article and reduced capacities of their windings only for certain range of the supply voltage and load value shown advantageous properties regarding the accuracy of the transfer of non-sinusoidal voltages. However in this limited range they enable more precision determine of the power quality.
9
PL
Przekladnik prądowy jako część systemu elektroenergetycznego stanowi element łączący obwód pierwotny linii elektroenergetycznej obwodem wtórnym wykorzystywany do pomiarów i/ lub zabezpieczeń. W związku z tym może on tworzyć główną drogę do przenoszenia zakłóceń między tymi obwodami. Przedmiotem artykułu są analizy ilościowa i jakościowa transferu zakłóceń przewodzonych o częstotliwościach do 9 kHz :rzez przekładniki prądowe z rdzeniem toroidalnym wykonanym z różnych materiałów magnetycznych.
EN
Current transformer being a part of electro-energy system is an element of connection between power lines on the primary side of the . oltage transformer and protection circuits and / or measurcment circuits connected to its secondary side. In connection with this fact voltage ?ansformer is a mam coupling path of conductive disturbances transfer between this two circuits. The subjects of an article are quantitative and :'jalitative analysis of transfer of conductive disturbances of freąuencies below 9 kHz by the current transformers. (Selected aspects of the slectromagnetic compatibility ofthe current transformers).
10
Content available remote Voltage transformer operation in connection with the power quality
EN
Conductive disturbances in the supplying voltage may affect the root mean square voltage and shape of the voltage curve on the mains which reflect in degradation of the power quality. The object of the article is the discussion of the results of the laboratory studies of the transmission of conductive disturbances from primary side of the voltage transformer to the secondary side and inversely.
PL
Zakłócenia przewodzone w napięciu zasilającym mogą wpłynąć na wartość skuteczną tego napięcia oraz kształt krzywej jego przebiegu, co może powodować pogorszenie jakości energii elektrycznej dostarczanej do odbiorników oraz układów zabezpieczeń. Przedmiotem artykułu są wyniki badań laboratoryjnych zjawiska przenoszenia przez przekładniki napięciowe zakłóceń przewodzonych z ich obwodów pierwotnych do obwodów wtórnych i odwrotnie.