Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  composite panel wall
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper presents an experimental study to investigate the seismic performance of steel- and composite steel-panel wall strengthened steel frames (SPWF and CPWF). A detailed experimental investigation of five 1/3-scaled specimens with one-bay and single-story was conducted. The failure modes, load-carrying capacity, hysteretic behavior, ductility, energy dissipation capacity were presented and analyzed. The effects of the length-to-height ratio, stiffeners, and the type of walls on the seismic behavior were also investigated. The experimental results show that the specimens tolerate 4% to approximately 5% story drift, the steel- and composite steel-panel wall improved the seismic performance of the steel frame. The length-to-height ratio has had large effect on load-carrying capacity, initial stiffness, ductility and response modification factor. In addition, finite element (FE) models of SPWFs and CPWFs were established to simulate their nonlinear behavior, and the results were verified by the experimental results. The failure mode obtained from the numerical simulation was in accordance with the experimental phenomenon. Furthermore, formulas were developed to estimate initial lateral stiffness and shear strength of the test specimens, and such theoretical predictions were verified by the experimental results.
PL
W artykule przedstawiono przegląd metodologii oceny stanu technicznego warstwy fakturowej w trójwarstwowych elementach ściennych budownictwa wielkopłytowego oraz wyniki analizy obliczeniowej bezpieczeństwa warstwy fakturowej obciążonej dodatkowo ciężarem ocieplenia. W obliczeniach uwzględniono potencjalne wady materiałowo-wykonawcze (zmiana średnicy wieszaków m.in. wskutek korozji, zastosowanie różnych gatunków stali).
EN
The article presents the methodology review pertaining to the assessment of the technical status of the textured layer in the three-layered wall elements of the ‘great panel’ buildings, along with the results of the calculation analysis regarding safety of the textured layer which additionally needs to bear the load imposed by the thermal insulation. The calculation did take into account the potential faulty materials or execution of the works (change in the diameter of the hangers resulting from corrosion, using different steel-types).
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.