Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 22

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  compact fluorescent lamp
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
This article is focused on considerations based on experimental studies concerning changes of selected parameters of identical compact fluorescent lamps (CFLs) intended for use in buildings during their operation. The studies constituted a long-term experiment whose goal was an evaluation of selected operating parameters of the CFLs in terms of meeting the requirements set out in the specified regulations as well as the issue of marking the lamps with the energy efficiency class. The measurements were performed with the authors’ experimental setup consisting of original equipment designed and made especially for the purpose of the measurements. The studies covered registration of the luminous flux as well as selected electrical parameters such as active power, current and the power factor during the so-called “start-up time” and operation time equal to 100 h, 500 h, 1000 h, 2000 h, etc. with a 1000 h step. The studies were finished with the moment of natural burnout of the CFLs tested. The results showed that the biggest drawback of CFLs is lack of preservation of the required time to reach 60% of the stabilized luminous flux just after short time of lamp operation. Similarly when assessing the conformity of the parameters declared by the manufacturer that have been verified, it can be stated that they are true only at the initial stage of lamp operation.
PL
W artykule przedstawiono problemy związane z pomiarem zaburzeń przewodzonych świetlówek kompaktowych, przy zasilaniu układu pomiarowego napięciem odkształconym. Przedstawiono wyniki badań emisji świetlówek przy napięciu zasilającym odkształconym w granicach dopuszczonych przez normy. Stwierdzono wpływ odkształcenia na wyniki. Zaproponowano postępowanie pozwalające na przeprowadzenie jednoznacznej oceny świetlówek.
EN
The paper presents problems related to the conducted emissions measurement of compact fluorescent lamps when the measuring system is supplied with distorted voltage. The results of tests on the emission of fluorescent lamps at the supply voltage distorted within the limits permitted by the standards are presented. The influence of deformation on the results was found. A procedure has been proposed that would allow an unambiguous assessment of fluorescent lamps.
PL
W artykule na podstawie przeprowadzonych pomiarów, przeanalizowano wpływ zmiany warunków zasilania (kształtu przebiegu czasowego napięcia, częstotliwości oraz wartości skutecznej napięcia) na parametry elektryczne i fotometryczne kilkunastu zintegrowanych świetlówek kompaktowych, wyposażonych w elektroniczne układy stabilizacyjno-zapłonowe. W przypadku dwóch lamp o barwach ciepłej i białej dodatkowo zarejestrowano rozkłady widmowe, na podstawie których obliczono współrzędne chromatyczności, temperaturę barwową najbliższą oraz współczynniki będące miarą wierności oddawania barw – a mianowicie: wskaźnik oddawania barw i skalę jakości barw.
EN
The paper presents the analysis of the influence of supply changes (shape of voltage waveform, frequency and voltage rms) on electrical and photometrical parameters of several integrated fluorescents equipped with electronic ignition/stabilization system. Additionally in case of two lamps with a warm and white colures, spectral concentration was registered basing on which chromaticity coordinates, correlated colour temperature, Colour Rendering Index and Colour Quality Scale was computed.
EN
The problems connected with generation of higher harmonics by supply circuits in compact lighting sources have been presented in this paper. The results of laboratory tests of the selected fluorescent lamps from three different manufacturers have been included. The measured light sources were supply by stable programmed NetWave source from EMTest. It allowed to characterize each fluorescent lamp taking into consideration the generation of higher harmonics of current.
PL
Artykuł dotyczy generowania wyższych harmonicznych przez układy zasilające wykorzystywane w kompaktowych źródłach światła. W artykule zamieszczono wyniki badań laboratoryjnych wybranych świetlówek kompaktowych wyprodukowanych przez trzy różne firmy. Badane świetlówki kompaktowe zasilane były sinusoidalnym napięciem, które dostarczane było ze stabilnego programowalnego źródła zasilania NetWave firmy EMTest. Dzięki temu scharakteryzowano każdą z badanych świetlówek pod względem generowania wyższych harmonicznych prądu.
PL
Tematyka publikacji dotyczy problemu generowania wyższych harmonicznych prądu przez kompaktowe fluorescencyjne źródła światła. W opracowaniu przeanalizowano zmiany poziomu harmonicznych prądu generowanych przez tego typu odbiorniki w sytuacji gdy zasilano je napięciem sinusoidalnym i odkształconym. Do generacji przebiegów napięcia zasilającego w trakcie badań Kwykorzystano, stabilne programowalne źródło zasilania NetWave firmy EMTest. Uzyskane dzięki temu urządzeniu napięcia miały stabilne niezmienne parametry w czasie. trwania badań.
EN
The problem of generation of current higher harmonics by compact fluorescent light sources is described in this paper. The above-mentioned light sources were supplied by a sinusoidal voltage with THD equal to 0.1% then by a distorted voltage with THD equal to 6.58%. Both voltages were generated by a NetWave device from the EMTest. Such equipment guarantees the stable parameters during tests. The compact fluorescent lamps (9 W of nominal power) were used in the conducted tests. They were from three different manufacturers marked as A, B and C. The specifications of the tested lamps are presented in Tab. 1. The characteristic of the examined fluorescent lamps was included in the paper for two cases. In the first one, each lamp was supplied by a sinusoidal voltage. The obtained results are presented in Tabs. 2 and 3 as well as in Fig. 4. The next step was group operation of lamps (A1, A1+A2 and A1+A2+A3) manufactured by the same A factory and (A1+B1+ C1) manufactured by A, B and C factories. The results of investigations are presented in Tab. 4 and Figs. 5 and 6. In the second case, the same configurations of fluorescent lamps were supplied by a distorted voltage. The results are illustrated in Tabs. 5, 6 and 7 as well as in Figs. 7, 8 and 9.
6
Content available remote Investigation of harmonic generation from dimmable LED lamps
EN
The purpose of this paper is to investigate harmonic generation from dimmable Light Emitting Diode lamps (LEDs) which are used in residential and commercial applications as an energy efficient lighting systems. It is done by conducting laboratory tests on various LED lamps and tapping the load current behavior under different conditions. Then the frequency domain analysis is performed to investigate the generated harmonics. Harmonic levels of different wattage, various branded dimmable and non dimmable LED bulbs along with dimmable compact fluorescent lamps are experimentally evaluated and compared. Experimental result shows that, all LED lamps generate very high level of harmonic during dimming operation which may affect the power quality of AC mains.
PL
W artykule opisano zagadnienie emisji harmonicznych przez ściemnianą diodę LED, wykorzystywaną do oświetlania pomieszczeń. Przeprowadzono próby laboratoryjne w różnych warunkach pracy, a na ich podstawie analizy generowanych harmonicznych. Pod tym kątem dokonano porównania działania badanych diod z innymi energooszczędnymi rozwiązaniami.
PL
W artykule przedstawiono problem związany z zastępowaniem źródeł żarowych przez źródła energooszczędne, głównie lampy fluorescencyjne, zgodnie z rozporządzeniem Komisji (WE) NR 244/2009. Promieniowanie ultrafioletowe emitowane przez źródła wyładowcze może stanowić zagrożenie dla użytkowników. Przeprowadzono badania sondażowe wybranych źródeł światła, które wykazały, że świetlówki dostępne na rynku nie stanowią istotnego zagrożenia ze względu na emisję UV, a produkty azjatyckie nie wykazują zwiększonego poziomu emisji w porównaniu do produktów europejskich.
EN
In this paper there is presented the problem of replacing incandescent light sources by energy saving sources, especially by compact fluorescent lamps, in accordance with European Commission Regulation No 244/2009 [1]. Section 2 describes the principle of operation of a fluorescent lamp (Fig. 1). This lamp is a source of ultraviolet radiation (Tab. 1) [3] which can be a health threat for users. The UV spectrum has many effects, both beneficial and damaging, to human health. Section 3 characterizes these effects such as the production of vitamin D, the treatment of skin conditions, but also acute and chronic effects especially on the skin and eyes. Section 4 describes normative conditions of UV emission level and functionality conditions of compact fluorescent lamps according to the European Commission Regulation. Section 5 presents the detailed research method and results. There were measured two parameters: ultraviolet irradiance and illuminance, which were used to calculate the UV radiation emission level. For research there were used 20 W power compact fluorescent lamps with about 1200 lm luminous flux. The characteristics of UV emission depending on the radiating angle, the source distance and the voltage (Figs. 4-8) were obtained. There was performed a comparison of emission of different lamps, according to the producer, construction and color temperature (Figs. 9, 10). The research shows that the lamps offered in the market are not a crucial health threat for users, because their emission level is lower than that specified in regulations. Also the emission level of Asian products is not much higher than that of European products.
PL
W artykule scharakteryzowano i porównano podstawowe parametry powszechnie stosowanych źródeł światła takich jak: żarówki, świetlówki i diody elektroluminescencyjne. Na podstawie wyników wykonanych pomiarów możliwe jest określenie jakości światła emitowanego przez dane źródło, pobór mocy czynnej i biernej oraz inne parametry. Zbadano również trwałość wybranego źródła żarowego.
EN
In the paper basic properties of commonly used light sources are described and compared. Light sources like: incandescent, fluorescent and electroluminescent are tested using a special equipment. Results show quality of generated light, active and passive power demand and others. The stability of a selected incandescent light source was checked.
9
Content available remote Skutki zastąpienia tradycyjnej żarówki energooszczędnymi zamiennikami
PL
W artykule przedstawiono wpływ na cechy ilościowe i jakościowe oświetlenia wynikające z zastąpienia tradycyjnych żarówek „energooszczędnymi” zamiennikami. Dodatkowo zaprezentowano zmiany parametrów elektrycznych oraz świetlnych w funkcji czasu od momentu załączenia pod napięcie poszczególnych źródeł światła. Przeanalizowano także parametry eksploatacyjne tj. temperaturę podczas pracy oraz wymiary i masę źródeł.
EN
In his paper, there is introduced influence on quantitative and qualitative lighting characteristics as a result of replacing traditional incandescence bulbs with its energy saving equivalents. Additionally changes in electrical and lighting parameters versus turning on time are presented. Utilization parameters were investigated i.e. temperature, dimension and weight.
PL
Analizie porównawczej poddano wartości kilkunastu parametrów opisujących sprawność i komfort widzenia, wyznaczonych u młodych i starszych wolontariuszy przy świetle żarówek oraz świetlówek kompaktowych o trzech temperaturach barwowych.
EN
Several parameters were analyzed, describing the efficiency and comfort vision, which were set in young and elderly volunteers in experiments with incandescent lamps and also with compact fluorescent lamps with tree color temperatures.
11
Content available remote Jak wybrać energooszczędny zamiennik tradycyjnej żarówki?
PL
W artykule przedstawiono wybrane parametry wycofywanych z rynku tradycyjnych żarówek głównego szeregu. Podano przykłady źródeł, w stosunku do których unijne wymogi nie mają zastosowania. Następnie zaprezentowano dostępne na rynku zamienniki tradycyjnych żarówek, ich rozwiązania konstrukcyjne oraz powszechnie stosowane nieprawidłowe określenia w odniesieniu do tych lamp. Z uwagi na szeroką ofertę energooszczędnych źródeł światła zaprezentowano także parametry opisujące właściwości zamienników konwencjonalnej żarówki, które powinny pomóc w podjęciu decyzji przy ich zakupie.
EN
In this paper there are introduced selected parameters of traditional bulbs set to disappear from the market. The examples of light sources are presented to which European Union regulations do not apply to. Next, there are introduced incandescence bulbs equivalents available at the market, its construction solutions and its commonly applied inappropriate descriptions. Taking into account broad market offer of energy saving lamps, there are introduced parameters characterizing conventional bulb equivalents and that should help buyer to make the correct choice. c) measuring a photometric solid of a reflected light). Słowa kluczowe: żarówka tradycyjna, żarówka halogenowa, świetlówka kompaktowa, LED-owe źródła światła.
PL
W artykule przedstawiono obwód Valley-fill, który jest prostym, tanim i o małych gabarytach pasywnym układem PFC efektywnie ograniczającym harmoniczne prądu zasilania fluorescencyjnych świetlówek kompaktowych małej mocy. Opracowano autorski model świetlówki w aplikacji PSPICE i porównano wyniki badań symulacyjnych z wynikami pomiarów świetlówki.
EN
In the paper, the Valley-fill circuit that may be used as a simple, cheap and of small dimensions passive PFC circuit for effective limiting input current harmonics of small power compact fluorescent lamps (CFL) has been presented. The author’s CFL PSPICE model has been developed and the results of simulation have been compared to results of measurements.
14
Content available remote Model świetlówki kompaktowej w środowisku PSPICE
PL
Wprowadzenie Rozporządzenia Komisji WE 244/2009 dotyczącego wymagań ekoprojektowych dla bezkierunkowych lamp do użytku domowego spowodowało wzrost zainteresowania energooszczędnymi źródłami światła. "Wszystkie żarówki, nawet te w prywatnych mieszkaniach, mają być zastąpione eergooszczędnymi" - zadecydowali przywódcy państw UE na szczycie w Brukseli. Obradujący premierzy i prezydenci 27 unijnych państw postanowili zmniejszyć zużycie energii w UE i chronić środowisko przed negatywnymi skutkami brudnych technologii energetycznych. Komisja Europejska przedstawiła propozycję legislacji nakazującą "wymianę żarówek w prywatnych domach". Skutki wymiany źródeł światła są istotne dla energetyki, jak i dla użytkowników. Stateczniki elektroniczne stosowane w świetlówkach kompaktowych zawierają układy przetwarzania AC-DC (sieciowy prostownik pełnofalowy) oraz DC-AC z tranzystorami kluczującymi z częstotliwością kilkadziesiąt kHz. Tego rodzaju nieliniowe odbiorniki powodują silne odkształcenie prądu zasilania, czego efektem jest wzrost poziomów wyższych harmonicznych w publicznej sieci niskiego napięcia. Badania umożliwiające analizę pracy świetlówek kompaktowych, a także ułatwiające projektowanie układów zasilania o niskiej zawartości harmonicznych można wykonać, wykorzystując komputerowe programy symulacyjne. Jednym z nich jest program PSPICE.
EN
Following the Commission Regulation (EC) No 244/2009 on ecodesign requirements for non-directional household lamps the authors have become interested in the question of wide-spread usage of compact fluorescent lamps (CFL) and its impact on power network quality. In order to analyze the functioning of CFL the PSPICE model of a lamp has been developed and the results of simulation have been compared to results of measurements.
17
Content available remote On the application of modern light sources - with emphasis on home lighting
EN
To be able to save lighting energy new light sources have to be introduced. This should not be done without considering the needs these sources have to serve for. In this paper we concentrate on the question of home lighting, and analyze why the compact fluorescent lamps did not find more widespread application in home lighting. We show that modern T5 fluorescent lamps have their application area in home lighting, and discuss what is needed to be able to introduce light emitting diodes in home lighting.
PL
Oszczędności energii na potrzeby oświetlenia wynikają ze stosowania nowoczesnych źródeł światła. Nie byłoby to możliwe bez rozpatrzenia potrzeb jakim powinny one odpowiadać. W artykule odniesiono się do oświetlenia mieszkań i analizowano brak szerszego stosowania świetlówek kompaktowych w oświetleniu mieszkań. Pokazujemy, że świetlówki liniowe T5 znajdują zastosowanie w oświetleniu mieszkań i rozważamy możliwości zastosowania diod elektroluminescencyjnych w oświetleniu mieszkań.
18
Content available remote Świetlówki kompaktowe jako źródła zaburzeń elektromagnetycznych
PL
W artykule przedstawione zostały wyniki badań laboratoryjnych odkształcenia prądu wywołanego pracą świetlówek kompaktowych dostępnych na rynku krajowym. Wyniki pomiarów porównane zostały z wartościami dopuszczanymi przez normy.
EN
The paper presents the results of laboratory tests of current distortion due to operation compact fluorescent lamps available in the domestic market. These results have been compared with the permissible values given in related standards.
19
Content available remote Świetlówki kompaktowe
PL
Artykuł prezentuje świetlówki kompaktowe ich konstrukcje, podstawowe typy i korzyści wynikające z ich stosowania.
EN
These paper give information about compact fluorescent lamps their construction, types and advantages during their application.
20
Content available remote Praca świetlówek kompaktowych w sieci trójfazowej
PL
W artykule przedstawiono rozważania dotyczące pracy świetlówek kompaktowych zasilanych z sieci trójfazowej czteroprzewodowej przy obciążeniu symetrycznym. Przedstawiono wyniki pomiarów wykonanych w sieci modelowej oraz wymieniono szkodliwe zjawiska jakie mogą wystąpić w rzeczywistej sieci zasilającej.
EN
In the paper there are presented considerations for operation of compact fluorescent lamps supplied from three-phase four-wire grid symmetrically loaded. The results of measurements carried out in model network are presented and unfavorable phenomena which can appear in real grid are specified.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.