Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  communal sewage sludge
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Composting is one of the most efficient ways of managing municipal sewage sludge. Recently, due to the increased demand for composting, the issue of conducting this process in cost effective way is of particular importance. Determining the early maturity stage of the composted material can significantly improve the efficiency of surface management of relatively expensive compost plant. The following research presents classification of neural models for determining the early stage of composted mixture of sewage sludge and rapeseed straw, basing on information contained in images of material samples obtained with UV-A illumination. The topology of the MLP network was used in the construction of classification models. As input variables, 25 color parameters and 21 texture parameters were originally used, but also steps were taken to eliminate their number. The classification error for the developed neural models ranged from 1.83 to 4.27%. The best model in terms of the lowest value of error, and the smallest number of input variables required, included 16 neurons in the input layer, 50 neurons in the hidden layer and 2 neurons in the output layer. The following model is characterized by a slightly lower classification error and a slightly simpler structure than the best possible model developed in earlier studies for visible light illumination.
PL
Kompostowanie jest jednym z najwłaściwszych sposobów zagospodarowania komunalnych osadów ściekowych. W ostatnim czasie, ze względu na wzmożone zapotrzebowania na kompostowanie tych osadów, szczególnego znaczenia nabiera kwestia prowadzenia tego procesu w sposób wydajny. Odpowiednio wczesne wykrywanie osiągnięcia przez kompostowany materiał stadium wczesnej dojrzałości może znacząco poprawić efektywność gospodarowania powierzchnią relatywnie drogiej płyty kompostowej. W pracy opracowano klasyfikacyjne modele neuronowe do określania tego stadium dla kompostowanej mieszaniny osadu ściekowego i słomy rzepakowej, bazujące na informacjach zawartych w obrazach próbek materiału, pozyskanych przy oświetleniu UV-A. Przy budowie modeli klasyfikacyjnych wykorzystano topologię sieci MLP. Jako zmienne wejściowe pierwotnie wykorzystano 25 parametrów dotyczących barwy oraz 21 parametrów dotyczących tekstury, przy czym wykonano również działania dążące do eliminacji ich liczby. Błąd klasyfikacji dla opracowanych modeli neuronowych zawierał się w przedziale od 1.83 do 4.27%. Najlepszy model pod względem najniższej wartości tego błędu, a przy tym najmniejszej liczby wymaganych zmienny wejściowych, zawierał 16 neuronów w warstwie wejściowej, 50 neuronów w warstwie ukrytej i 2 neurony w warstwie wyjściowej. Model ten cechował się nieco niższym błędem klasyfikacji i nieco prostszą strukturą, niż najlepszy z modeli opracowanych we wcześniejszych badaniach dla oświetlenia w postaci światła widzialnego.
PL
Celem prezentowanej pracy jest analiza możliwości usuwania metali z osadów oraz określenie skuteczności roztworów EDTA (kwas etylenodiaminotetraoctowy) w procesie ekstrakcji wybranych metali (Zn, Cu, Cd, Ni i Pb). W badaniach wykorzystano osady z przemysłu metalurgicznego oraz komunalne osady ściekowe. W osadach oznaczono całkowitą zawartość metali ciężkich po mineralizacji mieszaniną stężonych kwasów mineralnych: HNO 3 i HCl (1+3 - woda królewska). Efektywność EDTA w usuwaniu metali badano, poddając próbki osadów ekstrakcji z zastosowaniem wody demineralizowanej oraz roztworów wodnych EDTA o stężeniach 0,01; 0,05; 0,10 mol/dm3 . Próbki osadów wytrząsano przez 6 godzin, następnie pozostawały one w kontakcie z roztworem do 24 godzin, po czym były sączone i uzyskane przesącze analizowano, oznaczając w nich zawartość wybranych metali ciężkich. Roztwory EDTA okazały się wydajnymi ekstrahentami do wyodrębniania metali zarówno z osadów przemysłowych, jak i komunalnych. Jednak obserwowano różnice dla poszczególnych metali w podatności na wymywanie. Uzyskane wyniki wskazują, iż efektywność usuwania metali zależy od rodzaju matrycy, w jakiej związany jest metal. Efektywność usuwania metali była również zależna od stężenia roztworu stosowanego jako ekstrahent, osiągając najwyższe wartości dla roztworów o stężeniu 0,100 mol/dm3.
EN
Sewage sludge formed in industrial wastewater treatment plants contains high amount of heavy metal ions. Especially electroplating, metallurgical, semiconductors production and printed circuit board industry generate wastewaters containing toxic metal ions. Significant concentration of heavy metals could be present in municipal sludge, especially one produced on treatment plants with high inflow of industrial wastewater. Classical treatment of that wastewater involving chemical precipitation under alkaline condition results in hazardous solid waste. High concentration of heavy metals in sludge is one of the most important environmental problems. The aim of this study was analysis of heavy metals removal from sewage sludge as well as determination of selected heavy metals (Zn, Cu, Ni, Cd and Pb) removal efficiency from industrial and municipal sludge using aqueous solutions of EDTA (ethylenediaminetetraacetic acid). Total content of analysed heavy metals (Zn, Cu, Ni, Pb) in sewage sludge was determined after digestion with mixture of concentrated mineral acids: HNO 3 and HCl (1+3 - aqua regia). Efficiency of EDTA solutions for selected heavy metals removal from industrial and municipal sludge was determined using the single step washing tests with deionized water and EDTA solution at concentration 0.010, 0.050, 0.075 and 0.100 mol/dm3 . Samples of dried and homogenized industrial as well as municipal sludge were shaken for 6 hours with EDTA solutions. The extracts were filtered and finally analyzed for heavy metals content by atomic absorption spectrophotometry. The removal of analyzed metals was dependent on concentration of extracting agent and raised with increasing concentration of EDTA. Optimal concentration of EDTA for analyzed heavy metals removal from industrial and municipal sludge was determined as 0.100 mol/dm3 . Calculated efficiencies for optimal concentration of EDTA solution used for industrial sludge extraction were 68, 67, 19, 60 and 41% and for municipal sludge: 26, 5, 35, 25 and 50% for Zn, Cu, Ni, Cd and Pb, respectively. Studied metals removal from the industrial wastewater sludge was in the order: Zn ≥ Cu>Cd>Pb>Ni and from the municipal: Pb>Ni>Zn ≥ Cd>Cu. The results indicated that heavy metals removal efficiency changed for different types of solid matrix. Zinc, copper and cadmium were strongly connected to municipal organic type sludge, while lead and nickel rather to mineral industrial sludge.
3
Content available remote Bilansowanie ilości osadów powstających w komunalnych oczyszczalniach ścieków
PL
Metoda bilansowania komunalnych osadów ściekowych. Ilość powstających osadów uzależniona jest od przyjętej technologii oczyszczania oraz od wielkości obiektu . W zależności od zastosowanej technologii oczyszczania ścieków w oczyszczalni mogą powstawać osady wstępne z oczyszczania wstępnego, osady nadmierne z oczyszczania biologicznego oraz osady z oczyszczania chemicznego w różnych proporcjach. W analizowanych przypadkach przyjęto, że ścieki będą oczyszczane biologicznie technologią osadu czynnego.
EN
The method of balancing communal sewage sludge; the amount of sludge depends on applied treatment technology and the size of the object. Depending on the applied technology of sewage treatment in the plant, there might appear introductory sludge (from introductory cleansing), excessive sludge (from biological cleansing) and chemical sludge (from chemical cleansing of different proportions). In the analyzed cases it has been accepted that the sewage will be treated biologically, using the active sludge method.
4
Content available remote Wybrane zagadnienia spalania i współspalania komunalnych osadów ściekowych
EN
Development prognosis for focal communal sewage sludge management methods. Dynamics of sludge flow increase - a comment on selected legal aspects. Concept of thermic sludge reshaping. Selected aspects of sludge co-burning.
5
Content available remote Wykorzystanie biomasy w połączeniu z energią słoneczną
PL
W opracowaniu zaprezentowano wybrane zagadnienia związane z wykorzystaniem komunalnych osadów ściekowych do nawożenia plantacji wierzby energetycznej. Wyprodukowana biomasa wykorzystywana jest jako paliwo w procesie zgazowania. Przedstawiono również sposób wykorzystania pieca specjalnej konstrukcji do spalania odpadów drzewnych we współpracy z kolektorem słonecznym. Zaprezentowano podstawowy schemat technologii zagospodarowania niebezpiecznych odpadów organicznych.
EN
In the thesis problem of communal sewage sludge utilization to fertilize plantation of energetic willow has been presented. The produced biomass is being used as a specific fuel in a gasification process. The cooperation of specific construction wood combustion stove and solar collector was also presented in the thesis. As well as the basic technology of utilization dangerous organic waste products.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.