Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 22

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  collapse
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
Soil contamination with medicines can occur when unused or expired medications are improperly disposed of or when pharmaceutical manufacturing waste is inadequately treated or managed. Moreover, the largest percentage of damaged and expired medical materials in the sanitary landfill area during the COVID-19 period in the study region were Metronidazole (Flagyl) and Amoxicillin. The disposal of numerous drugs and medical waste from Al-Jazeera Pharmaceuticals Company, which were examined and found to have a higher concentration of the compound Metronidazole (Flagyl) and Amoxicillin, This study aimed to analyze the results of the impact of Metronidazole (Flagyl) and Amoxicillin concentrations on the chemical and geotechnical properties of soil. Undisturbed soil samples was collected and then cured by mixing 10 mg/l of Metronidazole (Flagyl) and 25 mg/l of Amoxicillin to the time period from 15 to 135 days. The obtained geotechnical tests results of natural and contaminated silty clay soil showed that the soil became softer, the cohesiveness between the particle sizes of soil decreased due to the absorption of the soil by the Metronidazole (Flagyl) and Amoxicillin concentration. Moreover, the results indicate that the soil collapse rose from 5.6 to 9.5 after 150 days of curing.
EN
The constant increase in energy demand and the need to reduce the carbon footprint on the environment has put countries in a race against time, looking for alternative resources or ways to supply this need. One of the main resources is solar radiation, which can be used to generate energy, initially on a small scale, but in recent years has been directed towards supplying large cities. The economic, political, and social investment must respond to planning and expansion criteria in order to generate feasible proposals. Through simulation of a real electrical system, the voltage instability was determined, which was corrected at software level by entering a photovoltaic solar plant, being this dimensioned from the PV curve obtained. Finally, the optimal location for the development of a solar photovoltaic plant among four possible scenarios was obtained through the application of an optimization algorithm. This approach was converted into an alternative applicable to different geographical locations.
EN
This study investigates the impact of teaching programmes on perceptions of sustainable development among students. The researchers argue that existing educational programmes must provide a comprehensive approach to mitigating collapse risk. To address this issue, the study developed a teaching programme to be delivered by experienced educators and experts, consisting of lectures, seminars, exercises, research projects, and related activities. The programme aimed to raise awareness of sustainable development and deepen understanding of the complexity of the subject. The results showed that the teaching programme increased students' appreciation of the importance of complexity and the nonlinear impacts of Black Swans in the sustainability discourse without changing their adherence to the New Ecological Paradigm. The study highlights the need for education to enable students to deal with problems characterised by complexity, uncertainty, and low probability, as well as high-impact events that pose a nonlinear threat to sustainable development.
PL
Celem badania była ocena wpływu interwencji dydaktycznych na postrzeganie zrównoważonego rozwoju przez studentów. Dotychczasowe badania wskazują, że realizowane pro-gramy kształcenia nie prowadzą do nabywania przez studentów odpowiedniego, kompleksowego podejścia do ograniczania ryzyka katastrofy. W badaniu zastosowano interwencję dydaktyczną w formie wykładów, dyskusji, ćwiczeń, projektów badawczych i działań prowadzonych przez doświadczonych nauczycieli i ekspertów. Interwencje miały na celu podniesienie świadomości i zrozumienia natury zrównoważonego rozwoju i jego złożoności. Wyniki pokazały, że program nauczania zwiększył uznanie uczniów dla znaczenia złożoności i nieliniowego wpływu Czarnych Łabędzi w dyskursie na temat zrównoważonego rozwoju, bez zmiany ich przywiązania do Nowego Paradygmatu Ekologicznego. Badanie podkreśla potrzebę edukacji umożliwiającej studentom radzenie sobie z problemami charakteryzującymi się złożonością i niepewnością oraz zdarzeniami o małym prawdopodobieństwie i dużym wpływie, które stanowią nieliniowe zagrożenie dla zrównoważonego rozwoju.
EN
The time-dependent behavior of three gypseous soils was investigated. The soils had gypsum content of 66%, 44%, and 14.8%. The mineralogical and chemical properties of the soils were determined. Two series of tests were performed. In the first, collapsibility characteristics were investigated for a long period (60 days) by conducting single and double oedometer tests. In the second series, the effect of relative density on collapse with time was investigated. The samples were compacted to 40%, 50%, and 60% relative density and then tested. The results of collapse tests showed that the relationship between the strain and logarithm of effective stress has two vertical lines. The first one represents the collapse settlement taking place within 24 h, while the second one represents the long-term collapse. The collapse potential (CP) in both single and double oedometer tests increases when the gypsum content increases from 14.8% to 66% and when the initial void ratio increases. The CP–logarithm of time relationship for soaked samples prepared at different relative densities under 800 kPa indicated that the CP increased with time for the soil sample compacted at 60% relative density and the increase was higher than those compacted at 40% and 50% relative density. The curves started with a straight line and then a concave downward curve was observed with a high strain. For samples compacted at 40% and 50% relative densities, the curves were interrupted by little soil collapses, while the third curve exhibited smooth relation following the collapse.
5
Content available remote Are Polish chemical periodicals doomed to collapse?
PL
W artykule przedstawiono przyczyny powstawania zagrożeń, awarii i katastrof obiektów budowlanych. Są to generalnie czynniki losowe niezależne od uczestników procesów budowlanych oraz czynniki zależne od błędów popełnionych przez uczestników procesów budowlanych i eksploatacyjnych.
EN
The article presents the causes of threats, failures and building catastrophes. These are generally random factors independent of participants in building processes. Factors depending on the mistakes made by participants in building and operating processes has also been shown.
7
Content available Forensic engineering. Part 2
EN
For decades structural engineers have been educated to design new buildings. This is certainly a good start of a career as a structural engineer since it is an appealing perspective to use creativity and to support society with structures that are safe and serviceable during a long service life. However, structures are often not built as they should be, which may result in malfunctioning, insufficient structural safety or even collapse. In such a case the cause of the problem has to be determined as quickly as possible in order to eliminate the risk or inconvenience for the users. To this aim experienced engineers are required, who are able to come to a quick assessment based on a reliable judgement. In the past, problems with structures were mostly incidental, but nowadays new tendencies are observed, like ageing of structures and their consequences, the use of software without understanding its background, and changes in the function of a structure during service life. That means that there is a growing need for another profile in structural engineering: the forensic engineer. The need and the requirements for such a new professional profile have been discussed in this paper.
PL
Od dziesięcioleci inżynierowie budowlani kształceni są w zakresie projektowania nowych budynków. Jest to z pewnością dobry początek kariery inżyniera konstrukcji, ponieważ stanowi realną możliwość wykorzystywania swojej kreatywności i wspierania społeczeństwa poprzez tworzenie obiektów bezpiecznych i trwałych w długim okresie użytkowania. Jednak konstrukcje często nie są budowane tak, jak być powinny, co może skutkować ich nieprawidłowym funkcjonowaniem, niewystarczającym bezpieczeństwem, a nawet zawaleniem się. W takim przypadku przyczynę problemu należy ustalić możliwie szybko, aby wyeliminować ryzyko lub niedogodności dla użytkowników. Do tego potrzebni są doświadczeni inżynierowie, którzy są w stanie dokonać szybkiej oceny w oparciu o wiarygodny osąd. W przeszłości problemy z konstrukcjami budowlanymi zdarzały się sporadycznie, ale obecnie obserwuje się nowe tendencje, takie jak starzenie się struktur ze wszelkimi tego konsekwencjami, stosowanie oprogramowania bez znajomości kontekstu i zmiany funkcji budynów w okresie ich użytkowania. Oznacza to, że istnieje rosnące zapotrzebowanie na inny profil w inżynierii budowlanej: inżyniera diagnosty. O potrzebach i wymaganiach dla takiego nowego profilu zawodowego traktuje ten artykuł.
8
Content available Forensic engineering. Part 1
EN
In this paper were conducted virtual tests to assess the impact of geometry changes on the response of metallic hexagonal honeycomb structures to applied loadings. The lateral compressive stress state was taken into consideration. The material properties used to build numerical models were assessed in laboratory tests of aluminium alloy 7075. The modelling at meso-scale level allow to comprehensive study of honeycomb internal structure. The changes of honeycomb geometry elements such as: fillets radius of the cell edges in the vicinity of hexagonal vertexes, wall thickness were considered. The computations were conducted by using finite element method with application of the ABAQUS finite element method environment. Elaborated numerical models allowed to demonstrate sensitivity of honeycomb structures damage process response to geometry element changes. They are a proper tools to perform optimization of the honeycomb structures. They will be also helpful in designing process of modern constructions build up of the considered composite constituents in various branches of industry. Moreover, the obtained results can be used as a guide for engineers. Conducted virtual tests lead to conclusion that simplification of the models of internal honeycomb structure which have become commonplace among both engineers and scientist can lead to inaccurate results.
PL
Agencja Ochrony Środowiska (EPA) twierdzi, że w Stanach Zjednoczonych ma miejsce codziennie ok. 700 pęknięć magistrali wodociągowych spowodowanych starzeniem się rurociągów. EPA szacuje, że USA będą musiały zainwestować ponad 334 mld USD w infrastrukturę przesyłu wody w ciągu najbliższych 25 lat.
PL
W niniejszej pracy zaprezentowano wybrane problemy dotyczące przebudowy konstrukcji nośnej obiektów budowlanych o tradycyjnej konstrukcji murowanej, których okres eksploatacji zbliża się do zakładanego okresu trwałości lub go przekroczył. W trakcie wykonywania tych robót budowlanych często usuwane są murowane ścianki działowe, w wyniku czego często dochodzi do powstania istotnych uszkodzeń konstrukcji nośnej, a w skrajnych przypadkach nawet do katastrof budowlanych. Rzeczoznawcy budowlani opracowujący oceny bądź ekspertyzy techniczne uszkodzonej konstrukcji murowanej jako rozwiązanie problemu zalecają niekiedy wykonanie tylko zbrojenia powierzchniowego uszkodzonych ścian. Zagadnienie istotnej zmiany rozkładu obciążeń w przebudowywanych budynkach o konstrukcji klasycznej jest złożone i w pewnych przypadkach powyższe zalecane rozwiązanie konstrukcyjne może okazać się niewystarczające dla zapewnienia bezpieczeństwa konstrukcji nośnej bądź bezpieczeństwa użytkowania obiektu. W pracy zaproponowano zakres diagnostyki i analizy pracy konstrukcji nośnej wybranego budynku, który pozwoli właściwie określić stopień występujących zagrożeń i na tej podstawie przeprowadzić prawidłową naprawę uszkodzonej murowanej konstrukcji, w tym jej wzmocnienie.
EN
Some problems of alteration for building structures of a conventional masonry for which working lifetime is approaching or has exceeded the expected design life are presented. In the course of these works, non-bearing masonry walls are often removed and as a result significant damages to supporting structures are often made, and in extreme cases even building collapses. Building surveyors who prepare a structural appraisal for technical reports of damaged masonry structures, as a solution to the problem, recommend sometimes to make only surface reinforcement of damaged walls. The question of significant change in the load distribution in alteration for buildings of conventional design is complex and in some cases above the recommended surface repairs may not be sufficient to ensure structural reliability or the safety of buildings exploitation. The paper proposes a scope of evaluation and structural analysis of a building, which allows to properly determine the range of the existing threats, and on this basis to carry out adequate repair of damaged masonry structures, including structural strengthening.
PL
Zabytkowe wieże często są postrzegane jako obiekty o szczególnej wartości, ponieważ społeczności identyfi kują się z nimi i dlatego pragną ochronić przed zawaleniem. W artykule autorzy prezentują dwa różne przykłady zabytkowych wież zagrożonych zawaleniem w Polsce i we Włoszech. Wieża kościoła w Otyniu (Polska) uległa zawaleniu w sierpniu 2012 roku. Wieża stanowiła jeden z najbardziej charakterystycznych elementów architektonicznych w okolicy. Murowana wieża wykonana była z cegły i kamienia. Wzniesiono ją w drugiej połowie XVIII wieku. Stan techniczny wieży uległ znacznemu pogorszeniu w miesiącach poprzedzających katastrofę, co było uwidocznione poprzez szybko powiększające się pęknięcia. Pomimo konsultacji z inżynierami i konserwatorami nie podjęto żadnych działań, aby zapobiec zawaleniu się wieży. Teren wokół wieży został zabezpieczony, ale ponieważ nie prowadzono monitoringu stanu technicznego wieży, nie podjęto też decyzji o wzmocnieniu jej konstrukcji. W konsekwencji doprowadziło to do katastrofy. Dzwonnica w Reno Centese (Włochy) została ukończona w 1883 roku. Do jej budowy wykorzystano cegły pochodzące z rozbiórki wieży, która wcześniej stała w tym samym miejscu. Obiekt został wzniesiony jako tuba na rzucie kwadratu, pusta wewnątrz, z drewnianą klatką schodową. W maju 2012 roku, w wyniku trzęsienia ziemi konstrukcja dzwonnicy uległa znacznemu uszkodzeniu. Ewakuowano najbliższe otoczenie budowli. Zastosowano prowizoryczne wzmocnienie konstrukcyjne, które umożliwi przeprowadzenie gruntownej renowacji. Przeprowadzone prace zapobiegły zawaleniu się obiektu.
EN
Towers are recognised as signifi cant monuments because communities identify with them and seek to protect from collapsing. The paper presents two different cases of collapsing towers from Poland and Italy. The church tower in Otyn (Poland) collapsed in August 2012. It was one of the most characteristic architectural elements of the area. The brick and stone tower was built in the second half of the eighteenth century. The structural condition of the tower deteriorated quickly in the months preceding the catastrophe as evidenced by a rapid increase in cracking. Despite consultations with engineers and conservators, no effort was made to prevent collapse of the tower. The area around the tower was secured but as there was no monitoring of the structural condition of the tower, no decision was taken to strengthen the structure. Collapse of the tower was the inevitable result. The bell tower in Reno Centese (Italy) was completed in 1883. It was built with bricks from a demolished tower, which had previously stood in the same place. The structure was built in the form of a square tube with an empty interior and a timber staircase on the inside. Considerable structural damage was sustained during an earthquake in May 2012. The area surrounding the tower was evacuated. Following structural provisional strengthening, the tower is ready for comprehensive restoration. Collapse was prevented.
EN
The main objective of this paper is to propose a new closed form solution, useful in the pre-design stage, that allows one to calculate the mean load in the case of post-collapse of polygonal thin-walled columns in the axial crushing case. This model gives a rapid and accurate evolution of the normalized mean load as function of the corner element angle as well as the ratio between the corner length and the column thickness. To identify the parameters of this model, numerical simulations with an explicit finite element software have been carried out and then compared to experimental results reported in the literature. Finally, all these results combined with the findings based on the known generalized mixed model developed by other researchers working on this topic enabled one to establish the closed form solution. This is a unified and continuous closed form solution, which is suitable for different columns shapes, even non-conventional shapes obtained thanks to the development of extrusion techniques.
PL
Konstrukcją nośną badanych hal jest powłoka walcowa, zaprojektowana z kształtowników giętych na zimno z blach stalowych grubości 1 mm - według systemu ABM. Profilowanie poprzeczne (w "fałdy") oraz podłużne (w łuk kołowy) kształtowników ABM odbywa się na placu budowy. Takie ustroje nośne są proponowane do wykonywania hal o rozpiętości nawet 25 m. Przedstawiono analizę bezpieczeństwa dwóch takich obiektów, których realizację wstrzymano, i takich dwóch hal, które uległy katastrofie.
EN
Paper describes the bearing structure shaped as a cylindrical shell, designed from cold-formed 1 mm thick steel plates, according to ABM system. The transversal shaping (folding) and longitudinal forming (a circular arch) from ABM profile is executed in situ. The structure is offered for halls with spans reaching oven 25 m. The work presents analysis of safety of two such objects whose execution was stopped and two other in Gdańsk and Tuszyn that have collapsed.
PL
Opisano katastrofę mostu o przekroju skrzynkowym, który w okresie oddania do eksploatacji miał największe na świecie przęsło z betonu sprężonego (240,8 m). Od katastrofy minęło już ponad 20 lat, ale dopiero w 2008 r. ujawniono dane techniczne umożliwiające bardziej racjonalną ocenę przyczyn i mechanizmu katastrofy mostu. W projekcie mostu zastosowano proste programy obliczeniowe i tradycyjne procedury projektowe, które nie modelowały prawidłowo konstrukcji wrażliwej na wpływy skurczu i pełzania betonu. Nadmierne ugięcia konstrukcji, duże straty siły sprężającej, nieudana naprawa i inne błędy doprowadziły do katastrofy mostu, której przyczyny można określić dopiero stosując współcześnie dostępne programy numeryczne i modele reologiczne betonu.
EN
The paper presents the box bridge collapse of world record span made of prestressed concrete. The collapse of the bridge was over 20 years ago but the technical data about the bridge inspections and failure were not released until 2008. In the original bridge design, the simple programs and standard design procedures were used. They did not exactly modelled the bridge superstructure which was very susceptible to creep and shrinkage of concrete. Excessive deflections of superstructure, huge prestress loss, unsuccessful repair and others faults led to the bridge collapse. The reasons of collapse can be explained using modern numerical programs and reological models of concrete.
PL
Artykuł zawiera przyczyny katastrofy ściany nośnej w zabytkowym budynku przemysłowym o konstrukcji murowej. Katastrofa nastąpiła w trakcie prac budowlanych związanych z przystosowaniem obiektu do funkcji galerii handlowej. Sformułowano wnioski w zakresie zminimalizowania ryzyka popełnienia błędu przy wprowadzaniu zmian konstrukcyjnych w tego typu obiektach, zarówno na etapie projektowania, jak i realizacji robót budowlanych.
EN
The paper contains the analysis of the reasons for load-bearing wall collapse in the historical industrial masonry building while conducting the building works connected with its adaptation to the function of commercial centre. There were formulated conclusions as to the elimination of risk of faults while carrying out structural changes, both for design and building works realization stage.
17
Content available remote A Hybrid Model of WTC Collapse
EN
A new theory of the WTC collapse is advanced that uses both fracture waves and progressive failure. According to the hybrid theory the WTC collapses ran in two phases: (i) in the first phase dynamic fracture waves disintegrated a considerable part of the towers producing the dust cloud and explosion sound well-documented and well-evidenced, and (ii) in the second phase the progressive failure front disintegrated the lower part of the towers that remained intact in the first phase. To illustrate many possible modes of progressive failure the slowest mode, the fastest mode, and three intermediate modes were first studied and then the hybrid mode was introduced. The hybrid theory allows one to get rid of evident defects of earlier theories and explain all basic facts and observations of the matter not understood before, in particular, why the time of all collapses was free fall time independent of the position of critical floor. An analysis and calculations given in the present paper do not depend on how fracture waves were produced.
18
Content available remote Tragedia w Minneapolis
19
Content available Panorama of the post-mine residual risks
EN
The mining industry residual risks can be divided into 6 main chapters which are as follows: surface instability, waste mechanical instability, waste chemical instability, waste fire, tailing dam’s instability, and residual contamination. Most of these risks are present in every old mine but their importance would depend mainly on the mining method, the depth, the type of ore or overburden materials, and the method of the dam building. They can be very different from one site to another. It seems to be important to analyse them site by site, and create a procedure to prevent all the buildings or infrastructures in the risky area from destruction. This procedure could be similar to the Seveso type industry building restrictions.
PL
Zagrożenia występujące na terenach opuszczonych przez przemysł górniczy można podzielić na następujące kategorie: niestabilność powierzchni terenu, mechaniczna i chemiczna niestabilność składowisk odpadów górniczych, pożary hałd górniczych, niestabilność składowisk odpadów poflotacyjnych oraz ogólne zanieczyszczenie terenu. Większość tych zagrożeń występuje na wszystkich terenach starych kopalń, jednakże zależą przede wszystkim od stosowanych metod wydobywczych, głębokości kopalń, rodzaju rudy i nadkładu oraz metody konstrukcji składowiska poflotacyjnego. Rodzaj zagrożeń może bardzo różnić się w zależności od kopalni. Należy zatem zbadać je w każdym przypadku oddzielnie, a następnie dla każdego przypadku opracować niezależne procedury ochrony wszystkich budowli oraz infrastruktury znajdujących się na zagrożonym terenie. Taka procedura może być wzorowana na ograniczeniach wypracowanych dla budowli przemysłowych w przypadku Seveso.
PL
W pracy zaprezentowano nowe urządzenie - konsolidometr hydrauliczny Rowe'a, którego rozwiązania konstrukcyjne, a szczególnie możliwość badania dużych prób, możliwość zagęszczania badanego gruntu bezpośrednio w komorze aparatu, zapewnienie wysokiego stopnia nasycenia próby oraz wysoka dokładność pomiarów jednoznacznie wskazują na jego pełną przydatność w badaniach odkształceń objętościowych gruntów nasypowych w wyniku ich zawodnienia. Wskazano na liczne i istotne zalety konsolidometru, a szczególnie na możliwość przeprowadzania badań zgodnie z obecnie zalecanymi standardami światowymi. Pracę uzupełniono o propozycje schematów badań pęcznienia gruntów nasypowych w oparciu o ASTM D 4546-96, najczęściej stosowane schematy badań osiadania zapadowego oraz procedury zagęszczania gruntów w komorach konsolidacyjnych Rowe'a
EN
The paper presents the new instrument - the Rowe's consolidation cell. The construction of the instrument provides the new opportunities: measurements of large samples, compaction of studied soil directly in the cell, high degree of saturation and high accuracy of measurements. All the factors unequivocally point out to a full applicability of the instrument measurements of volumetric strain of fill soils caused by inundation. The paper point to the numerous important advantages of the consolidation cell, particularly the consistence with recommended world standards. The schemes were proposed for measurements of swelling of fill soils based upon the ASTM D 4546-96 most commonly applied schemes for measurements of wetting-induced collapse and Proctor compaction procedures in Rowe's consolidation cells
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.