The ever-increasing demand for electricity and the need for conventional sources to cooperate with renewable ones generates the need to increase the efficiency and safety of the generation sources. Therefore, it is necessary to find a way to operate existing facilities more efficiently with full detection of emerging faults. These are the requirements of Polish, European and International law, which demands that energy facilities operate with the highest efficiency and meet a number of restrictive requirements. In order to improve the operation of steam power plants of electric generating stations, thermal-fluid diagnostics have been traditionally used, and in this paper a three-hull steam turbine, having a high-pressure, a medium-pressure and a low-pressure part, has been selected for analysis. The turbine class is of the order of 200 MW electric. Genetic algorithms (GA) were used in the process of creating the diagnostic model. So far, they have been used for diagnostic purposes in gas turbines, and no work has been found in the literature using GA for the diagnostic process of such complex objects as steam turbines located in professional manufacturing facilities. The use of genetic algorithms allowed rapid acquisition of global extremes, that is efficiency and power of the unit. The result of the work undertaken is the possibility to carry out a full diagnostic process, meaning detection, localization and identification of single and double degradations. In this way 100 % of the main faults are found, but there are sometimes additional ones, and these are not perfectly identified especially for single time detection. Thus, the results showed that with a very high success rate the simulated damage to the geometrical elements of the steam turbine under study is found.
PL
W opracowaniu przedstawiono problematykę przeciwdziałania awariom przemysłowym. Skoncentrowano się na branży energetycznej. Przybliżono strukturę wytwarzania energii w Polsce. Zaprezentowano proces wytwarzania energii elektrycznej w konwencjonalnej elektrowni węglowej. Na podstawie analizy literaturowej i studium przypadków zidentyfikowano jedną z najczęstszych przyczyn awarii w elektrowniach węglowych – wybuch pyłu węglowego – i w tym aspekcie zaproponowano zastosowanie analizy drzewa błędów FTA. Rozwiązanie to ma na celu przedstawienie błędów w prawidłowym funkcjonowaniu instalacji elektrowni, co pozwala zidentyfikować zdarzenia podstawowe i pomaga dobrać prawidłowo zabezpieczenia, które mogą w rozpatrywanej sytuacji przeciwdziałać wskazanemu zdarzeniu.
EN
The paper presents the problem of preventing industrial failures. The study focuses on energy industry. The structure of energy production in Poland has been reviewed and the process of production of electricity in the conventional coal-fired power plant has been presented. Based on the literature analysis and case study, coal dust explosions have been identified as one of the most common reasons of failure in coal-fired power plants – and in this aspect the proposal to use FTA fault tree analysis has been offered. The aim for this solution is to present errors in the correct functioning of power plant installations which allows to identify basic events and helps to correctly select security measures that may counteract the indicated event in the considered situation.
PL
W artykule przedstawiono algorytm obliczeń bloku energetycznego węglowego z układem odzysku ciepła odpadowego spalin metodą pośrednią. Obliczenia wykonano dla dwóch paliw: węgla kamiennego i brunatnego. Zbadano wpływ zainstalowania układu odzysku ciepła odpadowego spalin na wzrost mocy oraz sprawności bloku referencyjnego o mocy 900 MW. Wyniki pokazały, że zastosowanie układu odzysku ciepła odpadowego spalin poprawia sprawność bloku: dla węgla kamiennego o 1,57 %, a dla węgla brunatnego o 2,4%.
EN
The aim of the article is to present an algorithm of computation of a coal-fired power unit with indirect waste heat recovery system. Calculations were made for two fuels: lignite and bitominous coal. The influence of the installation of flue gases waste heat recovery system on power increase and efficiency of the 900 MW reference power unit was studied. Results showed that installation of flue gases waste heat recovery system improves power unit efficiency: for lignite by 1.57%, and for bituminous coal by 2.4%.
PL
Celem artykułu jest wskazanie, czy w obecnych warunkach rynkowych istnieje ekonomiczne uzasadnienie budowy nowych mocy wytwórczych w energetyce, dla których paliwem będzie węgiel kamienny. W artykule zawarta jest analiza opłacalności budowy nowego bloku energetycznego o mocy 910 MW.
EN
The aim of the article is the indication, if the construction of new coal-based power generation capacity is economically reasonable under current market conditions. It includes a cost-effectiveness analysis of the construction of a new power unit (910 MW).
EN
Radioactive contamination of the environment means a higher concentration of radioisotopes with regard to background level. Undoubdtedly, the incidental or permanent emissions of radionuclides to the environment are the sources of radioactive pollution. In this connection the diversity of radioisotopes distribution in nature can be observed. The key aim of the presented work was to ascertain the presence of radioactive elements and their decay products in the environment. Nuclides were emitted by selected conventional coal-fired power plants located in the south of Poland. The samples from the neighbourhood of three power plants and a sample from “clean” territory were measured. Additionaly, we measured the concentration of 137Cs istotope descended from the Chernobyl disaster.
PL
Przedstawiono parametry systemu energetycznego oraz strukturę paliw, produkcji i sprzedaży energii elektrycznej w okresie transformacji gospodarki. Poddano analizie koszty wytwarzania energii elektrycznej w elektrowniach pracujących na węglu brunatnym i kamiennym. Określono różnice występujące w poszczególnych składnikach kosztów wytwarzania w wieloletnich szeregach czasowych. Wskazano na zróżnicowane ceny zakupu energii elektrycznej przez PSE i ich istotny wpływ na kształtowanie się ekonomicznych wskaźników w elektrowniach. Zasygnalizowano występujące zmiany na rynku energii elektrycznej związane z jego liberalizacją, stosowaniem zasady TPA oraz pojawieniem się nowych podmiotów biorących udział w sprzedaży energii elektrycznej.
EN
Power engineering system parameters as well as fuel, production and sale structure of electricity during the transformation period was presented. Electricity production costs in lignite and hard coal fired power plants were put under analysis. Differences occurring in the particular components of production costs in multi-annual time period were determined. Diversified purchase prices of electricity by PSE and their significant impact on shaping the economic indices in the power plants were indicated. Changes occurring on the electricity market related with its liberalization, observance of the TPA principle and emergence of the new entities taking part in the electricity sales were signaled.
PL
Podjęto próbę oceny realizacji proekologicznego funkcjonowania elektroenergetyki poprzez analizę zmian struktury paliw wykorzystywanych do produkcji energii elektrycznej i ciepła oraz osiągnięć w ograniczeniu emisji gazów zanieczyszczonych i cieplarnianych do powietrza. Porównano uzyskane wyniki do zobowiązań akcesyjnych i standardów w najlepszych dostępnych technologiach (BAT) i perspektywicznych wyzwań.
EN
An undertaking was attempted to assess the power sector operation through analysis of changes in the fuel structure used in the electricity and a heat production and achievements in reduction of pollutants and greenhouse gases emission. Obtained results were compared to accession obligations and standards in the best available techniques and future challenges.
first rewind previous Strona / 1 next fast forward last