Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  ciśnienie wewnątrzczaszkowe
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Purpose: This computational study explores modelling and finite element study of the implant under Intracranial pressure (ICP) conditions with normal ICP range (7 mm Hg to 15 mm Hg) or increased ICP (>I5 mm Hg). The implant fixation points allow implant behaviour with respect to intracranial pressure conditions. However, increased fixation points lead to variation in deformation and equivalent stress. Finite element analysis is providing a valuable insight to know the deformation and equivalent stress. Methods: The patient CT data (Computed Tomography) is processed in Mimics software to get the mesh model. The implant is modelled by using modified reverse engineering technique with the help of Rhinoceros software. This modelling method is applicable for all types of defects including those beyond the middle line and multiple ones. It is designed with eight fixation points and ten fixation points to fix an implant. Consequently, the mechanical deformation and equivalent stress (von Mises) are calculated in ANSYS 15 software with distinctive material properties such as Titanium alloy (Ti6Al4V), Polymethyl methacrylate (PMMA) and polyether-ether-ketone (PEEK). Results: The deformation and equivalent stress results are obtained through ANSYS 15 software. It is observed that Ti6Al4V material shows low deformation and PEEK material shows less equivalent stress. Among all materials PEEK shows noticeably good result. Conclusions: Hence, a concept was established and more clinically relevant results can be expected with implementation of realistic 3D printed model in the future. This will allow physicians to gain knowledge and decrease surgery time with proper planning.
PL
Miniaturowy wzmacniacz typu dysza-przysłona jest głównym podzespołem przyrządów do pomiaru ciśnienia wewnątrzczaszkowego i wewnątrzgałkowego oraz fali tętna krwi. Wzmacniacz jest wyposażony w gumową membranę, spełniającą rolę przysłony. Dzięki temu wzmacniacz uzyskuje ujemne sprzężenie zwrotne. Stosunkowo mała średnica membrany (4,5 - 6,5 mm) stwarza pewne problemy przy projektowaniu wzmacniaczy, związane z zapewnieniem im zadowalającej dokładności statycznej i dynamicznej. Zostały one pokonane dzięki odpowiedniemu doborowi odsadzenia dyszy, oporności dławika i ciśnienia powietrza zasilającego.
EN
A miniature nozzle-flapper amplifier is a main part of the sensors for measuring intracranial and intraocular pressures, as well as blood pressure waveform. The amplifier is equipped with a rubber membrane, which plays a role of the flapper. Thanks to this the amplifier gets a negative feedback. A small diameter of the membrane (4.5 - 6.5 mm) makes up some design problems, connected with a steady- state and dynamic accuracy. The problems have been overcome by adequate choice of the nozzle offset, capillary resistance, and supply pressure.
PL
Przeprowadzono wstępną analizę wartości mierzonych parametrów ciśnienia we-wnątrzczaszkowego (ICP), ciśnienia tętniczego krwi (RR), ciśnienia atmosferycznego (Pa), temperatury pacjenta (Tp) i temperatury otoczenia (Ta) u czterech pacjentów z wodogłowiem normotensyjnym, u których prowadzono ciągły pomiar ciśnienia wewnątrz-czaszkowego przy użyciu czujnika piezoelektrycznego metodą podtwardówkową i monitora firmy Codman. Wartości pomiarowe poddano stosownej analizie statystycznej. Potwierdzono istotną zależność pomiędzy skurczowym a rozkurczowym ciśnieniem wewnątrzczaszkowym oraz pomiędzy skurczowym i rozkurczowym ciśnieniem tętniczym krwi. Niezależnie od tego uwagę zwraca dość silna korelacja, jak dla układów biologicznych, pomiędzy ciśnieniem wewnątrzczaszkowym a ciśnieniem atmosferycznym (przy p = 0,05). Jest to korelacja ujemna. Dotychczas w badaniach nad ciśnieniem wewnątrzczaszkowym niewiele miejsca poświęcono wpływowi ciśnienia atmosferycznego na zmiany ciśnienia we-wnątrzczaszkowego. Przyjęto, niemalże jako pewnik, wniosek z badań Petersona z lat czterdziestych XX wieku, że takiej zależności się nie obserwuje.
EN
Complexity of brain monitoring in clinical practice stimulated many studies on mathematical models. Most of available brain signaIs as intracranial pressure, cerebral blood flow, brain tissue oxygenation, etc., can be measured only invasively or indirectly. Function of the mathematical models is to extrapolate limited direct information derived trom few accessible modalities to complex descriptors which cannot be directly measured, such as compliance of craniospinal axis or autoregulation of cerebral blood flow. Three models deseribing cerebrospinal fluid pressure-volume compensation, cerebral blood flow and bihemispherical haemodynamics are presented along with examples, how their application may help in development ofnew diagnostic methods applicable in clinical neurosciences.
PL
Przedstawiono metodę zwiększenia częstotliwości przenoszenia pneumo-elektrycznego przetwornika ciśnienia wewnątrzczaszkowego. Elektryczny sygnał wyjściowy przetwornika jest przetwarzany według określonego algorytmu w komputerze, w którym jest rejestrowane ciśnienie wewnątrzczaszkowe. Przytoczono równanie, opisujące wspomniany algorytm oraz wyniki laboratoryjnych badań charakterystyk częstotliwościowych wzmacniacza typu dysza-przysłona.
PL
Opisano model matematyczny pneumatycznego czujnika ciśnienia wewnątrzczaszkowego, opartego na miniaturowym wzmacniaczu typu dysza-przysłona, objętym ujemnym sprzężeniem zwrotnym. Opracowany model ma postać transmitacji widmowej i jest przeznaczony do badania stabilności oraz do kompensacji dynamicznej czujnika. Model został zweryfikowany za pomocą doświadczalnych charakterystyk częstotliwościowych modelowanego czujnika.
EN
The mathematical model of the pneumatic intracranial pressure sensor, based on the miniature nozzle-flapper amplifier with negative feedback is described. The formulated model is in the form on the sinusoidal transfer function and will be used for stability investigation and dynamic compensation of the sensor. The model has been verified by means of the experimental frequency characteristics.
PL
W pracy przedstawiono analizę zmian ciśnienia wewnątrzczaszkowego (Intracranial Pressure - ICP) i ciśnienia perfuzyjnego (Cerebral Perfusion Pressure - CPP) u 273 pacjentów leczonych w Klinice Neurochirurgii Akademii Medycznej we Wrocławiu w latach 1994-1997 po operacjach guzów mózgu (132), tętniaków (56), krwiaków urazowych (60) i krwiaków samoistnych (25). Stosowano standardowe leczenie pooperacyjne z indywidualnym prowadzeniem każdego pacjenta w zależności od rodzaju schorzenia i aktualnego stanu. Stan neurologiczny pacjenta przy wypisie określono wg Glasgow Outcome Scale (GOS). Określono wartości średnie i przedziały istotności ICP i CPP dla każdej grupy GOS w kolejnych trzech dniach po operacji w zależności od rodzaju schorzenia. U wszystkich pacjentów stwierdzono charakterystyczne przebiegi zmian ICP i CCP, niezależnie od rodzaju schorzenia, zaś zależne od ciężkości i stanu chorych.
EN
Analysis of Intracranial Pressure (ICP) and Cerebral Prefusion Pressure (CPP) values in 273 patients treated in years 1994-1997 in the Department of Neurosurgery, Wroclaw Medical University after cerebral tumours (132), aneurysms (56), traumatic (60) and spontaneous (25) haematomas operations is presented. Standard postoperative traetment with individually adapted management depending on a patient state was administrered. Neurological state of patients at the discharge was qualified according to Glasgow Outcome Scale (GOS). Mean values and Confidential Intervals (CI) of ICP and CPP for all the GOS groups and types of diseases during the first three days after operation were determined. Characteristic changes of ICP and CPP in all of the groups, depending on severity of state and kind of ilness, was stated. The necessity of intensive treatment of ICP rises and CPP changes in the earliest phase (first day) after operation was stated which influences the results of treatment greatly.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.