Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  ciągłe monitorowanie stężenia glukozy
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Recent technological advancements in diabetes technologies, such as Continuous Glucose Monitoring (CGM) systems, provide reliable sources to blood glucose data. Following its development, a new challenging area in the field of artificial intelligence has been opened and an accurate prediction method of blood glucose levels has been targeted by scientific researchers. This article proposes a new method based on Artificial Neural Networks (ANN) for blood glucose level prediction of Type 1 Diabetes (T1D) using only CGMdata as inputs. To show the efficiency of our method and to validate our ANN, real CGM data of 13 patients were investigated. The accuracy of the strategy is discussed based on some statistical criteria such as the Root Mean Square Error (RMSE) and the Mean Absolute Percentage Error (MAPE). The obtained averages of RMSE are 6.43 mg/dL, 7.45 mg/dL, 8.13 mg/dL and 9.03 mg/dL for Prediction Horizon (PH) respectively 15 min, 30 min, 45 min and 60 min and the average of MAPE was 3.87% for PH = 15 min, knowing that the smaller is the RMSE and MAPE, the more accurate is the prediction. Experimental results show that the proposed ANN is accurate, adaptive, and very encouraging for a clinical implementation. Furthermore, while other studies have only focused on the prediction accuracy of blood glucose, this work aims to improve the quality of life of T1D patients by using only CGM data as inputs and by limiting human intervention.
EN
Type 1 diabetes (T1D) is a chronic disease requiring patients to know their blood glucose values in order to ensure blood glucose levels as close to normal as possible. Hence, the ability to predict blood glucose levels is of a great interest for clinical researchers. In this sense, the literature is rich with several solutions that can predict blood glucose levels. Unfortunately, these methods require the patient to specific their daily activities: meal intake, insulin injection and emotional factors, which can be error prone. To reduce this burden on the patent, this work proposes to use only continuous glucose monitoring (CGM) data to predict blood glucose levels independently of other factors. To support this, support vector regression (SVR) and differential evolution (DE) algorithms were investigated. The proposed method is validated using real CGM data of 12 patients. The obtained average of root mean square error (RMSE) was 9.44, 10.78, 11.82 and 12.95 mg/dL for prediction horizon (PH) respectively equal to 15, 30, 45 and 60 min. The results of the present study and comparison with some previous works show that the proposed method holds promise. The SVR based on DE algorithm achieved high prediction accuracy while being robustness, automatic, and requiring no human intervention.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.