Chlorine-disinfected model water after preliminary oxidation with chlorine dioxide of different composition was used in investigations. Extracts from model water samples with different TOC and NH4(+) ions after elution with acetone were applied in the Salmonella assay in TA100 test strain. The higher the concentration of those parameters, the higher the concentration of such chlorine derivatives as AOX and chlor(o)acetic acids in water, and the stronger the mutagenic activity of organic water pollutants observed in the tests conducted without metabolic activation. Only water that contained less TOC than 2.0 g/dm3, irrespective of the ammonia concentration (0.1; 0.5; 1.0 g NH4(+)/dm3), did not show mutagenic effects in tests conducted either with or without metabolic activation.
PL
Wodę modelową o różnym składzie wstępnie utleniano dwutlenkiem chloru, a następnie dezynfekowano chlorem. Do testu Salmonella przeprowadzanego na szczepie TA100 wprowadzano ekstrakty z próbek wodnych. Ekstrakty te wymywano acetonem z wód modelowych o różnej zawartości OWO i jonów amonowych. Wraz ze zwiększeniem się stężenia OWO i jonów amonowych wzrastało w wodzie stężenie chloropochodnych takich jak AOX i kwasy chlorooctowe oraz mutagenne działanie organicznych zanieczyszczeń wody w testach przeprowadzanych bez aktywacji metabolicznej. Jedynie woda o zawartości OWO 2,0 g C/dm3, niezależnie od stężenia NH4(+) (0,1; 0,5; 1,0 g NH4(+) /dm3), zarówno w testach z aktywacją metaboliczną, jak i bez niej nie wykazywała właściwości mutagennych.