Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  chlorine decay
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Chlorination of water belongs to the basic methods of its disinfection and is commonly used, permanently or periodically, as the final stage of water treatment in many water treatment stations in Poland. Although, the chlorination process is a well-known phenomenon, the selection of an appropriate dose of disinfectant is still a difficult task. The lack of chlorine in the water or its excessively low content (below 0.2 mg × dm–3) may result in the lack of microbiological protection of water flowing through the pipes. A reverse situation is also unfavourable. The use of too high doses of chlorine at the entrance to the network, on the one hand, ensures adequate disinfectant concentration even in the fittings of the network, on the other hand, it can lead to dangerous for health disinfection by-products (DBPs) including trihalomethanes (THMs). The selection of the proper dose of chlorine should take into account factors affecting its consumption, chemical parameters of water as well as hydraulic parameters of water transport. Such possibilities are available due to application of numerical modelling to study the transport of chlorine in water. The aim of the presented research is to analyse the effectiveness of chlorination of water in a selected water supply network. Simulation tests were carried out for the various doses of disinfectant supplied to the network for the assumed duration of the simulation – 168 hours. The qualitative model was developed in the Epanet 2.0 software using a hydraulic model of the tested network. The first order chlorine decay reaction was assumed to modelling studies, with applied literature values of decay rate of chlorine in water. The results of simulation tests of chlorine transport in the network revealed difficulties in choosing the right dose of chlorine necessary to ensure microbiological protection of water in the network. The forced flow allowed effective disinfection of water.
PL
W celu zapewnienia wody o wymaganej jakości i zapobiegania jej wtórnemu skażeniu mikrobiologicznemu, jest ona poddawana dezynfekcji za pomocą różnych dezynfektantów. Jednym z najpopularniejszych sposobów dezynfekcji wody jest jej chlorowanie. Prognozowanie zmian jakości transportowanej wody jest możliwe dzięki licznym modelom matematycznym jakości wody. Symulują one zmiany stężenia związków w systemie wodociągowym, ich reaktywność oraz pozwalają na śledzenie rozprzestrzeniania się środka dezynfekcyjnego i jego rozkładu. W pracy przeprowadzono badania symulacyjne rozkładu stężenia chloru z wykorzystaniem programu EPANET 2.0 w wybranym fragmencie rzeczywistej sieci wodociągowej. Do symulacji wykorzystano skalibrowany model hydrauliczny sieci. Przeprowadzono także badania laboratoryjne mające na celu wyznaczenie współczynnika rozkładu chloru w masie wody zasilającej badany system.
EN
In order to provide water of required quality and to prevent its microbiological recontamination, the water is disinfected by using various disinfectants. One of the most popular methods of disinfection is chlorination. Forecasting changes of quality parameters of transported water is made possible by numerous mathematical models of water quality. These models simulate changes of concentration of compounds in a water supply system, their reactivity, and they allow to track the decay of disinfectant. In this paper simulations of chlorine decay with the use of EPANET 2.0 in a selected part of the real water distribution system was conducted. For the simulation a calibrated hydraulic model of the network was used. Laboratory tests were also carried out to determine the coefficient of bulk decay of chlorine.
3
EN
Some issues concerning the most popular practical problems encountered during modeling the water quality in water distribution systems were presented. The mathematical basis of water quality modeling, commonly understood as chlorine distribution modeling, covering the governing equations, initial and boundary conditions description as well as required and necessary simplifications, were discussed. Then, the most popular computer models of water quality in distribution systems used in environmental engineering practice, such as: input-output (110) model, inverse chlorine decay model and forward simulation, were introduced. The modeling assumptions, model structure and limitations, advantages and disadvantages of given models were also discussed.
PL
Przedstawiono wybrane zagadnienia dotyczące najczęściej pojawiających się problemów w modelowaniu jakości wody wodociągowej. Zaprezentowano podstawy matematyczne modelowania numerycznego jakości wody, często pojmowanego jako modelowanie rozkładu chloru, obejmujące równania stanu, warunki brzegowe i początkowe. Przedstawiono także najczęściej stosowane uproszczenia w opisie matematycznym opisywanego zjawiska. Następnie w pracy omówiono najpopularniejsze modele jakości wody stosowane w inżynierii środowiska: model wejście-wyjście (110), model odwrócony oraz model postępujący. Zaprezentowano także założenia modelowe, struktury omawianych modeli, ich zalety oraz wady i ograniczenia.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.