EN
The paper presents a newly developed flow method with spectrophotometric detection for determination of ehlorites in drinking water. The method is based on reaction of chlorite ions with iron(II0 in an acidic environment. The analytical signal was measured for the coloured l;e(II)/o-phenanthroline complex at 512 nm. Determinations were carried out using a How system. Validation studies revealed that the method is linear in the analyte's concentration range 0.1-6.0 mg L-1 and assures determination precision RSD < 0.40%. Limit of detection and limit of quantification were estimated as 0.01 and 0.03 mg L-1,respectively. The interferences caused by different ions were studied taking into consideration their concentrations ranges occurring in water classified into four quality classes.The method was applied to the analysis of water samples taken from different intakesin Krakow (Poland) and the analytical results were compared with those obtained by ionchromatography method.
PL
W pracy przedstawiono metodę przepływową z detekcją spektrofotometryczną do oznaczania chloranów(III) w wodzie pitnej. Podstawą metody jest reakcja jonów chloranowych(III) z jonami Fe(Il) w środowisku kwaśnym i pomiar sygnału analitycznego dla barwnego kompleksu jonów Fe( II) z o-fenantrolinąprzy długości fali 512 nm. Oznaczenia wykonywano przy użyciu zestawu do analizy przepływowej. Badania walidacyjne wykazały, że metoda charakteryzuje siei iniowością w zakresie stężenia 0.1-6.0 mg L-1pozwalając na oznaczenia analitu z precyzja, (RSD) < 0.40%. Granice wykrywalności i oznaczalności analitu wynosiły odpowiednio 0.01 i 0.03 mg L1. Zbadano interferencje wywołane występowaniem różnych jonów w zakresach stężeń typowych dla wód o czterech klasach czystości. Metodę zastosowano do analizy próbek wód pobranych z różnych ujęć na terenie Krakowa. Otrzymane wyniki analityczne porównano z rezultatami otrzymanymi metodą chromatografii jonowej.
PL
Ochrona ludzi przed potencjalnymi niebezpiecznymi dla zdrowia mikroorganizmami obecnymi w wodach do picia, wymaga jej regularnej dezynfekcji różnymi metodami. Dezynfekcja taka przeprowadzana jest zazwyczaj za pomocą chloru. Jest to dobrze znana i efektywna technologia, posiadająca wiele zalet, jakkolwiek podczas jej stosowania tworzą się niebezpieczne dla zdrowia produkty uboczne takie jak min. trihalometany. Alternatywną wobec chlorowania metodą uzdatniania wód jest stosowanie ozonu lub ditlenku chloru. Pomimo niezaprzeczalnych zalet tych nowych metod, posiadają one również pewne wady. Dotyczą one głównie tworzenia się utlenionych nieorganicznych halogenopochodnych takich jak: bromiany, chloryny i chlorany. Niektóre z nich są zakwalifikowane jako substancje prawdopodobnie rakotwórcze dla ludzi. Bromiany mogą powstawać w wodach surowych zawierających bromki poddawanych procesom ozonowania. Stosowanie ditlenku chloru może powodować tworzenie się w nich chloranów i chlorynów. Niniejszy artykuł dotyczy powstawania, oznaczania oraz regulacji prawnych w zakresie ww. nieorganicznych utlenionych halogenopochodnych ubocznych produktów dezynfekcji wód do picia.
EN
In an effort the public from potentially hazardous microorganisms, drinking water supplies are routinely disinfected with a variety of treatment methods. Disinfections of drinking water are usually carried out by chlorination process. This is a well known, effective technology which has many advantages, however during this process dangerous for health by-products, such as trihalomethanes are formed. Another disinfection process which has emerged as the most promising alternative to chlorination technique is using of ozone or chlorine dioxide. In spite of undeniable advantages, there are certain undefined hazards resulting from this method of water treatment. It is especially due to formation of inorganic oxyhalide by-products such as bromate, chlorite and chlorate. Some of them have been classified as probable human carcinogen. Bromate can be form when source waters containing bromide are disinfected with ozone. The use of chlorine dioxide can cause formation of chlorite and chlorate. The paper presents the formation, determination and legal regulation of these inorganic oxyhalides disinfection by-products in drinking water.
PL
Określono zapotrzebowanie na dwutlenek chloru dla wody infiltracyjnej oczyszczonej w układach technologicznych obejmujących procesy napowietrzania i filtracji oraz napowietrzania, filtracji i sorpcji. Analizowano wpływ stężenia ogólnego węgla organicznego na dawkę dwutlenku chloru, a także zmienność niektórych wskaźników jakości wody. Stwierdzono, że wskutek działania utleniającego zastosowanego dezynfektanta w wodzie pojawiają się uboczne produkty utleniania, których stężenie malało, gdy w wodzie pozostawał wolny dwutlenek chloru. Stwierdzono także, że stosowanie dwutlenku chloru, poza działaniem dezynfekcyjnym, spowodowało obniżenie intensywności barwy i zawartości OWO w uzdatnianej wodzie. Wykazano, że dawka pokrywająca zapotrzebowanie wody na dwutlenek chloru wyraźnie zależała od początkowego stężenia OWO i była zawsze większa od dawki dezynfekcyjnej.
EN
Chlorine dioxide demand was determined in infiltration water after treatment by aeration and filtration or by aeration-filtration-sorption. The effect of TOC concentration on the chlorine dioxide dose, as well as the variability of some water quality parameters, was examined in more detail. It was found that the oxidizing activity of the disinfectant in the water accounted for the formation of some oxidation by-products and that their concentration decreased when free chlorine dioxide persisted in the water. The study also showed that chlorine dioxide not only acted as a disinfectant but also contributed to the reduction of coloured matter and TOC in the treated water. As it can be inferred from the analysis of the results obtained, the dose covering the chlorine dioxide demand in infiltration water depended noticeably on the initial TOC concentration and was higher than the disinfecting dose.