Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  chiral derivatizing reagents
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A reversed phase high-performance liquid chromatographic method has been established for enantioseparation of (R, S)-mexiletine. Two volatile and thermally stable acyl chlorides, viz., (S)-(—)-(N)-trifluoro acetyl prolyl chloride and (1S)-(—)-camphanic chloride, were used as chiral derivatizing reagents. Binary composition of aqueous trifluoroacetic acid (0.1%)-acetonitrile as mobile phase was successful with ultraviolet (UV) detection at 210 nm. The method was optimized and validated for accuracy, precision, and limit of detection. The limit of detection was found to be 45 ng mL -1 and 80 ng mL -1 for the two types of diastereomers. Besides, kinetic resolution was achieved, and the experimental conditions optimized for this purpose provided diastereomeric excess up to 74% for (R)-isomer. On achieving a resolution value greater than 2, the optimized method for analytical enantioseparation was scaled-up to smallscale preparative level, and the native (R)-mexiletine was recovered by acid hydrolysis of the diastereomer.
EN
A high-performance liquid chromatographic (HPLC) method was developed for enantioresolution of amino alcohols using an indirect approach. Two sets of chiral derivatizing reagents (CDRs) having amino acids (CDRs 1–4; set A) and their amides (CDRs 5–8; set B) as chiral auxiliaries in cyanuric chloride (CC) moiety were synthesized and characterized. Diastereomers of eight amino alcohols were synthesized, under microwave irradiation, using each of the eight CDRs. The resulting diastereomers were separated by reversed-phase high-performance liquid chromatography (RP-HPLC) using C18 column and eluting mixtures of acetonitrile with aqueous trifluoroacetic acid (aq.TFA) in a linear gradient (45 min) with UV detection at 230 nm. The results (in terms of resolution Rs and retention factor k) obtained for the two sets of diastereomers were compared among themselves and among the two groups. The effects of chiral auxiliaries (in terms of acid and amides variants), constituting CDRs, on separation were also evaluated. The elution order for the diastereomers was determined. The separation method was validated for limit of detection (LOD), linearity, accuracy, precision, and recovery.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.