Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 19

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  chemical sensors
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This article presents the validity, advisability and purposefulness of using a gas sensor matrix to monitor air deodorization processes carried out in a peat-perlite-polyurethane foam-packed biotrickling filter. The aim of the conducted research was to control the effectiveness of air stream purification from vapors of hydrophobic compounds, i.e., n-hexane and cyclohexane. The effectiveness of hydrophobic n-hexane and cyclohexane removal from air was evaluated using gas chromatography as the reference method and a custom-built gas sensor matrix consisting of seven commercially available sensors. The influence of inlet loading (IL) of n-hexane and cyclohexane on the biotrickling filtration performance was investigated. The prepared sensor matrix was calibrated with use of two statistical techniques: Multiple Linear Regression (MLR) and Principal Component Regression (PCR). The developed mathematical models allowed us to correlate the multidimensional signal from the sensor array with the concentration of the removed substances. The results based on gas chromatography analyses indicated that the elimination efficiencies of n-hexane and cyclohexane reached about 40 and 30 g m-3 h-1, respectively. The results obtained using a gas sensor matrix revealed that it was possible not only to determine concentration reliably of investigated hydrophobic volatile organic compounds in the gas samples, but also to obtain results of a similar high level of quality as the chromatographic ones. A gas-sensor matrix proposed in this work can be used for on-line real-time monitoring of biofiltration process performance of air polluted with n-hexane and cyclohexane.
PL
W artykule przedstawiono zasadność, celowość i sensowność zastosowania matrycy czujników gazowych do monitowania procesów dezodoryzacji powietrza prowadzonych w biofiltrze zraszanym (BTF) z wypełnieniem w postaci torf-perli-pianka poliuretanowa. Celem przeprowadzonych badań była kontrola procesowa skuteczności oczyszczania strumienia powietrza z par związków hydrofobowych, którymi były n-heksan i cykloheksan. Skuteczność usuwania hydrofobowego n-heksany i cykloheksanu z powietrza oceniono przy użyciu chromatografii gazowej jako techniki referencyjnej oraz skonstruowanej matrycy czujników gazowych składającej się z siedmiu komercyjnie dostępnych czujników. Zbadano wpływ obciążenia złoża (IL) n-heksanu i cykloheksanu na wydajności biofiltracji. Przygotowana matryca czujnikowa została skalibrowana z wykorzystaniem dwóch technik statystycznych: Multiple Linear Regression (MLR) oraz Principal Component Regression (PCR). Opracowane modele matematyczne pozwoliły skorelować wielowymiarowy sygnał z matrycy czujników ze stężeniem usuwanych substancji. Wyniki uzyskane na podstawie analiz chromatograficznych wykazały, że wydajność usuwania n-heksanu i cykloheksanu osiągnęły odpowiednio około 40 i 40 gm-3h-1. Wyniki uzyskane z wykorzystaniem matrycy czujników gazowych wykazały, że możliwe było nie tylko wiarygodne określenie stężeń badanych hydrofobowych lotnych związków organicznych w próbkach gazowych, ale również charakteryzowały się podobnie wysokim poziomem jakości jak wyniki chromatograficzne. Zaproponowana w tej pracy matryca czujników gazowych może być wykorzystana do monitorowania procesu biofiltracji powietrza zanieczyszczonego n-heksanem i cykloheksanem w czasie rzeczywistym.
PL
Poznanie niejednorodności, składu morfologicznego oraz mineralnego i chemicznego mikrocząstek popiołów lotnych węgli, kamiennego i brunatnego, jest niezbędne do oceny ich potencjalnego zagrożenia dla środowiska naturalnego.
PL
Ciągły rozwój nowoczesnych technologii stosowanych w przemyśle, diagnostyce medycznej oraz monitoringu środowiska sprawia, że wzrasta zapotrzebowanie na niewielkie, proste urządzenia umożliwiające szybkie i niezawodne określenie składu badanych próbek. Wymogi te spełniają czujniki chemiczne, które łączą w sobie zarówno czułość i selektywność klasycznych metod analitycznych, jak i duże możliwości ich miniaturyzacji i automatyzacji obsługi.
4
Content available Hydrogel-based chemical and biochemical sensors
EN
Hydrogels are cross-linked polymer networks able to absorb or to release large amounts of water. The water uptake is associated with a considerable volume change but also with changes of optical properties like the refractive index. The swelling can be excited by a large spectrum of different physical (e.g. temperature, electrical voltage, magnetic field) and chemical factors (e.g. pH value, concentrations of chemical or biochemical species). The particular sensitivity can be adjusted by tayloring the composition of the hydrogel or via its functionalization. If the interaction between hydrogel and analyte to be measured is reversible then such hydrogels are becoming a promising candidate for miniaturized, cost-effective and inline-capable sensors.
PL
Hydrożele są usieciowanymi sieciami polimerowymi zdolnymi do absorbowania lub uwalniania dużych ilości wody. Pobór wody wiąże się ze znaczną zmianą objętości, ale także ze zmianami właściwości optycznych, takich jak współczynnik załamania światła. Pęcznienie może być wzbudzane przez różne czynniki (np. temperaturę, napięcie elektryczne, pole magnetyczne) i czynniki chemiczne (np. pH, stężenie substancji chemicznych lub biochemicznych). Pożądaną czułość można uzyskać przez odpowiedni skład hydrożelu lub poprzez jego funkcjonalizację. Jeśli oddziaływanie między hydrożelem a analitem, który ma być zmierzony, jest odwracalne, wówczas takie hydrożele stają się obiecującym materiałem do budowy miniaturowych, ekonomicznie opłacalnych czujników.
PL
W pracy zbadano możliwość wykorzystania poli(dicyjanopropylosiloksanu) (PCNPS) jako pokrycia sensorowego w czujnikach z akustyczną falą powierzchniową (AFP), służących do detekcji fosforoorganicznych środków trujących. Polimer nałożono na rezonatory z AFP metodą napylania próżniowego. Badano odpowiedzi częstotliwościowe i amplitudowe czujników w stosunku do par dimetylometylofosfonianu (DMMP) w celu określenia czułości względem związków fosforoorganicznych. Badano również inne substancje testowe (heptan, triletyloamina (TEA), acetonitryl (ACN), dimetyloformamid (DMF), n-butanol) jako potencjalne interferenty. Uzyskano dużą czułość sygnału częstotliwościowego względem DMMP (ok. 500 Hz/ppm). Jednocześnie czułości względem pozostałych substancji testowych, z wyjątkiem DMF, znajdowały się na poziomie szumów pomiarowych. Niska temperatura zeszklenia fazy PCNPS, przekładająca się na dobre właściwości dynamiczne czujników, wskazuje na możliwość zastosowania tej fazy w czujnikach z AFP.
EN
The paper investigates applicability of poly(biscyanopropylsiloxane) (PCNPS) as a chemosensitive coating agent for surface acoustic wave (SAW) sensors to organophosphorus chemical warfare agent (CWA) detection. The polymer was deposited on SAW resonators by vacuum evaporation. Sensor sensitivity to organophosphorus compounds was investigated using dimethyl methylphosphonate (DMMP) vapors via sensor frequency and amplitude response testing. Also, other substances from the set (heptane, triethylamine (TEA), acetonitrile (ACN), dimethylformamide (DMF), n-butanol) were tested as potential interference factors. Excellent sensitivity of frequency signal was achieved (about 500 Hz/ppm) against DMMP. Sensitivity toward the remaining test substances, except for DMF, was comparable to the noise level. Low glass transition temperature of the PCNPS phase, corresponding to good dynamic properties of the sensors, indicates suitability of this phase for application in SAW sensors.
PL
Metody analizy sensorycznej są wykorzystywane do identyfikacji źródeł uciążliwości zapachowej znajdujących się w pobliżu terenów zamieszkałych. Używa się jej również w przypadku rozpatrywania wniosków dotyczących budowy nowego zakładu przemysłowego lub innej działalności gospodarczej mogącej w sposób niekorzystny oddziaływać na środowisko.
PL
Wykorzystanie metod analizy sensorycznej umozliwia identyfikację źródeł emisji odorów znajdujących się w pobliżu terenów zamieszkanych oraz weryfikację skarg ludności na uciążliwość zapachową.
PL
Czwarta i ostatnia część cyklu artykułów poświęconych automatyzacji w instalacjach klimatyzacji i wentylacji. W części pierwszej (. TCHK' nr 3/2012) autor omówił podstawowe pojęcia związane z zagadnieniem sterowania. Część druga cyklu (. TCHK' nr 312012) poświęcona była przybliżeniu takich zagadnień, jak: korekcja dynamiczna układów liniowych, stabilność układu sterowania, dokładność regulacji, czy wskaźniki jakości regulacji. Przedstawione zostały w niej również sterowniki oraz wielkości pomiarowe w układach klimatyzacji i wentylacji. W części trzeciej (. TCHK' nr 1/2013) autor przybliżył podstawy tworzenia układów sterowania. Omówił również podstawowe procesy obróbki cieplno-wilgotnościowej powietrza, które ilustruje wykresem Molliera dla każdego analizowanego przypadku. W części czwartej przedstawiona została charakterystyka techniczna urządzeń pomiarowych i wykonawczych stosowanych w układach automatyki instalacji klimatyzacji i wentylacji.
EN
This is the last, fourth part of paper dealing with automatic control systems in ventilation. In /he first part (,GHK" nr 3/2012) basic definitions have been given for control, signal, system of regulation, transmittance, element of regulating system etc The second part ("TGHK" nr 9/2012) dealt with such problems as dynamic correction of linear systems, stability of regulating systems and accuracy of control. Measured parameters in ventilating systems have been pointed. In the third part ("TCHK nr 1/2013) basic configurations of automatic control systems have been described. Heat treatment processes in ventilating systems have been ilIustrated on the Mollier chart. In the fourth part technical data of measuring equipment and actuators of automatic control systems used in air conditioning Technology are presented.
PL
Artykuł stanowi przegląd i charakterystykę kompozytowych materiałów elektrodowych zbudowanych na bazie polianiliny i PEDOT. Przedstawiono własności opisywanych polimerów przewodzących, oraz różne rodzaje materiałów kompozytowych otrzymywanych z ich użyciem. Opisano możliwości stosowania takich materiałów do modyfikowania elektrod stosowanych w bioelektroanalizie jako sensory chemiczne. Przedstawiono również zastosowanie warstw kompozytowych do unieruchamiania enzymów i tworzenia biosensorów. Omówiono trzy podstawowe rodzaje biosensorów z unieruchomioną oksydazą glukozową. Przedstawiono też możliwości stosowania warstw polimerów i kompozytów do budowy elektrod mikostrukturalnych do zastosowań w bioelektroanalizie.
EN
This paper provides an overview and characterization of composite electrode materials built on the basis of polyaniline and PEDOT. Properties of described conducting polymers and various types of composite materials obtained from them have been presented. Also the applicability of these materials to modify electrodes used in bioelectroanalysis as chemical sensors Has been described as well as the composite layers for enzymes immmobilization and biosensors production. Three basic types of biosensors with immobilized glucose oxidase have been discussed. Moreover the possibility to employ polymers and composites layers to construct microstructural electrodes for bioelectroanalysis have been described.
10
Content available remote Development of Algorithmic and Software Automated System for Environment
EN
The main difference between the developed information-measuring system and the existing is that the proposed algorithms provide high noise immunity and the probability of prompt detection chemicals in air in conditions of intense hindrance and noise.
PL
Na podstawie najnowszej literatury, omówiono właściwości elektryczne, optyczne, magnetyczne, mechaniczne i elektrochemiczne, metody otrzymywania oraz zastosowania polimerów elektroprzewodzących do budowy elementów elektronicznych, optoelektronicznych takich jak miniaturowe rezystory, kondensatory, diody, tranzystory, fotodiody, fototranzystory, lasery, światłowody oraz układów elektronicznych, w tym czujników i bioczujników wybranych wielkości chemicznych i biochemicznych, a także mikrosystemów do całościowej analizy biochemicznej (µTAS, lab-on-a-chip).
EN
Basing on recent publications, electrical, optical, magnetic, mechanical and electrochemical properties of conducting polymers, methods of their polymerization and doping, as well as their applications for manufacturing of resistors, capacitors, diodes, transistors, lasers, optical fibers, and sensors and biosensors of selected chemical and biochemical species, and biochemical micro total analysis systems (µTAS, lab-on-a-chip) are reviewed in the paper.
PL
Wykorzystanie czujników potencjometrycznych jako detektorów w chromatografii cieczowej (LC) i elektroforezie kapilarnej (CE), będące interesującym rozwiązaniem, nie jest praktycznie stosowane. Przeprowadzono elektroforezę kapilarną związków z grupy leków antyhistaminowych i antydepresantów, jako zminiaturyzowany czujnik potencjometryczny zastosowano elektrodę metaliczną (Φ = 250 μm) z polimerową membraną, pozostającą w bezpośrednim kontakcie z powierzchnią metalu. Uzyskano elektroforogramy rozdzielenia mieszanin badanych związków oraz wyznaczono krzywe kalibracyjne.
EN
Although, combination of liquid chromatography (LC) or capillary electrophoresis (CE) with potentiometric sensors seems to be interesting it is not commonly used. Capillary electrophoresis of antihistaminei and antidepressants was performed, using metallic electrode (Φ = 250 μm) covered with polymeric membrane as a miniaturized potentiometric sensor. Separation electropherograms of drug mixtures were obtained and calibration curves were plotted.
PL
Przedstawiono algorytm i program komputerowy do obliczeń akustycznych modów płytowych (AMP) w kryształach piezoelektrycznych. Obliczenia numeryczne i pomiary wykonano dla kwarcu o orientacji ST. Uzyskano dobrą zgodność obliczeń i pomiarów widma AMP o częstotliwościach nieco większych od częstotliwości akustycznej fali powierzchniowej (AFP). Pozwala to na ocenę tłumienności wtrąceniowej w paśmie zaporowym filtrów z AFP. Ze względu na możliwość wykorzystania jednej płaszczyzny płytki do wzbudzania AMP, a drugiej do pomiaru jej obciążenia mechanicznego lub elektrycznego, istnieje możliwość oddzielenia tych obszarów, co jest ważne w przypadku zastosowań w czujnikach chemicznych pracujących w agresywnym środowisku.
EN
An algorithm and a computer program for calculations of acoustic plate modes (APM) in piezoelectric crystals is presented. Numerical calculations and measurements were done for ST orientation of quartz. Good agreement of calculations and measurements was obtained for the APM spectrum, located at slightly higher frequencies than the surface acoustic wave (SAW) frequency. This allows to estimate the insertion loss in the stop bands of SAW filters. Because one plane of the plate can be used for APM excitation, while the other one for mechanical or electrical loading, it is possible to separate these areas, which is important in the case of applications in chemical sensors operating in an aggressive environment.
EN
The paper presents the results of studies on the production of planar optical waveguides to be applied in amplitude chemical sensors, using ion exchange technique Ag+<=>Na+ from the solutions of AgNO₃-NaNO₃. Substrates from BK-7 glass and from soda-lime glass were applied. The influence of the parameters of the applied technologies on the shape of refractive index profiles of the produced planar waveguides was presented. For the produced waveguides the dependence was determined between modal attenuation coefficients as the function of mode order as well as the uniformity parameters of modes reaction with absorption sensor layer.
PL
Omówiono podstawowe zagadnienia związane z wybuchowością mieszanin gazowych. Przedstawiono również stosowane w praktyce laboratoryjnej i przemysłowej takie urządzenia do monitorowania stężenia gazów palnych, jak: czujniki półprzewodnikowe, termokatalityczne i termokonduktometryczne.
EN
Basic information on gaseous mixture explosion phenomenon bas been presented. Devices commonly used in industrial and laboratory practice for monitoring of concentration of flammable gases, particularly semiconductor sensors, thermocatalytic sensors and thermoconductivity sensor, have presented and compared.
PL
Urządzenia typu elektroniczny język stanowią nowy kierunek rozwoju analityki chemicznej, który może być użyteczny w szybkiej zautomatyzowanej analizie jakościowej, a także w rozpoznawaniu wybranych grup produktów.
EN
This dissertation deals with three types of chemical sensor: ion-selective electrodes, ion-sensitive field effect transistors, and fibre optic chemical sensors. The sensors were designed for the environmental monitoring of ionic species in aqueous samples. The overall objective of this work was the optimisation of both the technology of the sensor fabrication and the whole measuring system. The work was performed independently in various aspects: a) the technology of sensor preparation b) a versatile head for sensor mounting c) the enhancement of sensor performance d) automated systems for testing sensors e) algorithms and software for measuring systems management. This interdisciplinary work required the utilisation of analytical chemistry, material science, the hydrodynamics of fluids, electronics, computer science etc. As a result several original constructions of chemical sensors and techniques for the preparation of chemical interfaces were developed and patented. The designed versatile sensor head, thanks to its modular construction, is capable of having various types of chemical sensor mounted (potentiometric, optical etc.). Assembled multi-channel measuring systems, based on the signal conditioning units designed by the author, are fully automated. This allows for the testing of many sensors without the operator's attendance. Measuring performances of the sensors such as: calibration curve, selectivity, response time, repeatability, temperature dependence etc. can be determined with the help of the systems. Special algorithms and software working in the Windows system were also developed.
PL
W pracy opisano wyniki badań trzech typów czujników chemicznych: elektrod jonoselektywnych, jonoczułych tranzystorów polowych oraz światłowodowych czujników chemicznych. Czujniki projektowano do pomiaru stężenia wybranych jonów w mediach wodnych do zastosowań w ochronie środowiska. Celem pracy była optymalizacja parametrów metrologicznych czujników chemicznych, konstrukcja zautomatyzowanych stanowisk pomiarowych oraz opracowanie metod badawczych pozwalających ocenić przydatność zaprojektowanych czujników do monitorowania stanu środowiska naturalnego. Prace prowadzone były równolegle na kilku płaszczyznach: - technologia wytworzenia czujnika - uniwersalna głowica do montowania różnych typów czujników - optymalizacja własności pomiarowych - projekt i budowa zautomatyzowanych stanowisk pomiarowych do testowania czujników chemicznych - opracowanie algorytmów oraz programów komputerowych nadzorujących pracę systemów.Interdyscyplinarny charakter prowadzonych prac wymagał wykorzystania wiedzy z zakresu chemii analitycznej, inżynierii materiałowej, hydrodynamiki płynów, elektroniki, informatyki. Prowadzone prace konstrukcyjne i technologiczne zakończyły się zgłoszeniem kilku patentów dotyczących nowych typów czujników oraz metod wytwarzania warstw interfejsów chemicznych. Skonstruowana głowica przepływowa umożliwia prowadzenie badań czujników chemicznych różnego typu (potencjometry cznych, optycznych i innych), dzięki swej modułowej konstrukcji. Zbudowane wielokanałowe stanowiska pomiarowe, z wykorzystaniem własnych rozwiązań układów kondycjonujących sygnały pochodzące z czujników, są całkowicie zautomatyzowane. Umożliwia to testowanie dużej ilości czujników bez konieczności ingerencji użytkownika. Systemy umożliwiają wyznaczenie podstawowych parametrów metrologicznych czujników takich jak: krzywa kalibracji, selektywność, czas reakcji, powtarzalność sygnału, zależności temperaturowe itd. Dla potrzeb tych systemów opracowano specjalne algorytmy i według nich wykonano odpowiednie oprogramowanie pracujące w środowisku Windows.
PL
Wybrane streszczenia zaproszonych i ustnych prezentacji z VI Knferencji "Czujniki optoelektroniczne i elektroniczne" COE'2000 (Gliwice, 13--16 czerwca) podano w skrócie. Przedstawiono kilka informacji o wydarzeniach towarzyszących konferencji i Walnym Zjeździe Polskiego Towarzystwa Techniki Sensorowanej.
EN
Selected invited and oral presentation abstracts from the VI Conference on Optoelectronic and Electronic Sensors - COE'2000 (Gliwice, June 13--16) proceedings are summarized. Seeral informations about the conference events and PTTS society convention are given as well.
PL
Niniejsza praca jest przeglądem praktycznych zastosowań czujników chemicznych w monitoringu gazowych zanieczyszczeń powietrza. Przedstawione zostały charakterystyki analityczne głównych grup czujników: elektrochemicznych, elektrycznych, optycznych, termochemicznych i masowych. Szczegółowo została omówiona grupa elektrochemicznych czujników gazów, a wśród nich mające obecnie najszersze zastosowanie czujniki amperometryczne oraz staoelektrolitowe, potencjometryczne czujniki tlenu.
EN
Present work reviews the application of chemical gas sensors in monitoring of air pollutants. The fundamental classes of sensors are presented with particlar reference to their practical use in continuous environmental analysis. The analytical characteristics of the electrochemical, electrical, optical, thermochemical, and gravimetrical sensors are discussed and compared. The special attention is paid to the most common class, i.e. to the electrochemical sensors and the amperometric and potentiometric sensors of oxygen pressure are presented in details.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.