Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  charakterystyka termiczna
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The influence of the chill on the AlSi7Mg alloy properties after the heat treatment T6, was realised in the system of the horizontally cast plate of dimensions 160x240 mm and thickness of 10 and 15 m. The cooling course in individual casting zones was recorded, which allowed to determine the solidification rate. Castings were subjected to the heat treatment T6 process. Several properties of the alloy such as: hardness BHN, density, tensile strength UTS, elongation %E were determined. The microstructure images were presented and the structural SDAS parameter determined. The performed investigations as well as the analysis of the results allowed to determine the influence zone of the chill. The research shows that there is a certain dependence between the thickness of the casting wall and the influence zone of the chill, being not less than 2g, where g is the casting wall thickness. The next aim of successive investigations will be finding the confirmation that there is the dependence between the casting wall thickness and the influence zone of the chill for other thicknesses of walls. We would like to prove that this principle is of a universal character.
PL
Do konsolidacji górotworu w wyrobiskach górniczych coraz częściej stosowane są dwukomponentowe kleje poliuretanowe. W czasie wtłaczania kleju, w wyniku reakcji polimeryzacji, powstaje produkt utwardzony zwiększający spójność skał wokół miejsca zastosowania. Reakcji tej towarzyszy wydzielanie ciepła i lokalny wzrost temperatury. W artykule przedstawiono metodykę badań dołowych (in situ), których celem było wyznaczenie maksymalnych wartości temperatury reakcji wiązania czterech różnych klejów poliuretanowych. Na podstawie pomiarów opracowano przebiegi zmian temperatury w czasie trwania reakcji wiązania aż do całkowitego utwardzenia kleju, których wyniki zostały zaprezentowane w niniejszym artykule. Pomiary temperatury wykonywane były (in situ) w trakcie rutynowych prac związanych z klejeniem górotworu w trzech kopalniach GZW.
EN
The two-component polyurethane adhesives are used more and more frequently for rock-mass consolidation in the mine workings. During forcing of an adhesive into rock-mass, due to reaction of polymerisation, a hardened product is created which increases in a coherence of rocks around a place of application. The reaction is accompanied by a heat release and a local rise in temperature. A methodology of the underground trials (in situ) has been presented aiming at determination of maximum values of temperature of bond reaction of four various polyurethane adhesives. On the basis of measurements there have been developed the courses of temperature changes during the bond reaction until the ultimate hardening of the adhesive. The results have been presented in the paper. The measurements of temperature (in situ) have been made during routine works relating to cementation of a rock-mass in three GZW mines.
EN
Purpose: In the metal casting industry, an improvement of component quality depends mainly on better control over the production parameters. Thus, a thermal analysis cooling curve of the alloy is used for process control in the aluminum casting industry. In this work effect of cooling rate on the size of the grains, SDAS, size of the β precipitation and thermal characteristic results of AC AlSi9Cu cast alloy have been described. The solidification process was studied using the cooling curve and crystallization curve at solidification rate ranging from 0,16 ºCs-1 up to 1,04 ºCs-1 Design/methodology/approach: The experimental alloy used in this investigation was prepared by mixing the ACAlSi5Cu commercial alloys and two master alloys AlSi49 and AlCu55. Thermal analysis tests were conducted using the UMSA Technology Platform. Cooling curve thermal analysis was performed on all samples using high sensitivity thermocouples of K type. Data were acquired by a high speed data acquisition system linked to a PC computer. Each chilled sample was sectioned horizontally where the tip of the thermocouple was located and it was prepared by standard grinding and polishing procedures. Optical microscopy was used to characterize the microstructure and intermetallic phases. Secondary Dendrite Arm Spacing measurements were carried out using an Leica Q-WinTM image analyzer. Findings: Increasing the cooling rate increases significantly the liquidus temperature, nucleation undercooling temperature, solidification range and decreases the recalescence undercooling temperature. Increasing cooling rate refines all microstructural features. Research limitations/implications: This paper presents results for one alloy - AC AlSi9Cu only, for the assessment of the Silicon Modification Level didn’t include the arrangement of a Si crystal in a matrix. Originality/value: Original value of the work is applied the artificial intelligence for the assessment of the Silicon Modification Level.
EN
The Cu68.5Ni12P19.5 alloy was prepared using 99.95 wt % Cu, Cu-P and Ni-P master alloys. The precursors were encapsulated in quartz tubes under vacuum (10^-2 bar) and melted in resistance furnace. Metallographic observations of the alloy were combined with measurement of volume fraction of microstructural constituents in as-cast state. The ribbon was cast using melt spinnig technique. The ribbons were then investigated by means of differential scanning calorimetry (DSC) and differential thermal analysis (DTA). High temperature X-ray studies of the material were made in order to characterize the thermal stability. The characteristics of the alloy are discussed and compared with other experimental data.
PL
Stop Cu68.5Ni12P19.5 przygotowano wykorzystując 99,95% wag. Cu, zaprawy Cu-P oraz Ni-P. Składniki te zatapiano w kapsułach kwarcowych w próżni (10^-2 bar) i przetapiano w piecu oporowym. Przeprowadzono badania metalograficzne stopu w stanie lanym oraz wykonano pomiary ułamka objętościowego poszczególnych składników mikrostruktury. Odlano taśmę stosując technikę "melt spinning". Następnie, odlaną taśmę badano wykorzystując różnicową kalorymetrię skaningową (DSC) oraz różnicową analizę termiczną (DTA). W celu określenia stabilności termicznej przeprowadzono wysokotemperaturowe badania w dyfraktometrze rentgenowskim. Otrzymane wyniki porównano i przedyskutowano korzystając z innych istniejących danych eksperymentalnych.
PL
Przeprowadzono pomiary strumienia ciepła dla radiatora, przeznaczonego do odbioru dużych ilości ciepła z powierzchni modułów termoelektrycznych, w funkcji różnicy temperatury miejsca zamocowania modułu termoelektrycznego i temperatury otoczenia oraz przy różnej wielkości powierzchni modułu termoelektrycznego. Stwierdzono, że możliwe jest odbieranie strumieni ciepła o gęstości przewyższającej 50 kW/m2. Opracowano również przybliżony model teoretyczny umożliwiający przewidywanie tej charakterystyki radiatora. Stwierdzono dość dobrą zgodność wyników badań doświadczalnych i przewidywań teoretycznych.
EN
A compact radiator that can be used for intensive cooling of thermoelectric modules was proposed in the paper. The radiator consists of an aluminium plate with a large number of thin and closely spaced fins placed on it. A fan is used to force an air flow in spaces between the fins. A thermal characteristics (heat flux versus temperature difference) for the radiator was determined experimentally and through use of a simple theoretical model. It was found that application of the radiator allows for high cooling rates to be achieved correspondingto heat fluxes exceeding even 50 kW/m2. Higher cooling heat flow rates were observed for the greater portions of the radiator flat surface covered by the thermoelectric modules.
PL
Porównano charakterystyki termiczne i wymianę ciepła przy przemianach fazowych w urządzeniu chłodniczym do schładzania wody model RKM200. Urządzenie wyposażone było w wymienniki płytowe spawane typu EXEL i pracowało z czynnikami chłodniczymi R407C i R22. Stwierdzono znacząco gorsze współczynniki wymiany ciepła dla R407C w porównaniu z R22. Zaobserwowano istotne zmiany składu mieszaniny R407C podczas badań.
EN
Thermal characteristics and heat transfer parameters for phase changes occuring in refritgerating system type RKM200 used for chilling water have been compared. The system was equipped with plate heat exchanger EXEL and it worked with refrigeration agents R407C and R22. Significantly worse heat transfer coefficients for R407C in comparision with R22 have been found. Fundamental changes in R407C mixture composition have been observed in the course of investigation.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.