Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  cegła silikatowa
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
PL
Artykuł omawia występujące w budynkach problemy związane z akustyką i możliwości ich naprawy. Prezentuje także potencjał konstrukcji murowych z elementów silikatowych w zakresię ochrony akustycznej.
EN
The article discusses the problems with sound in buildings and the options of remedying such problems. In addition, the soundproofing potential of silicate brick designs is presented.
EN
This paper provides an assessment on how capillary flow affects the thermal parameters of the two popular materials for the construction of walls – ceramic and silicate bricks. In order to tackle this problem, it was necessary to conduct capillary water rise tests, consisting in recording changes in the mass of the materials in question, having them put in touch with liquid water. The dependence of the mass variation in time, measured for the individual samples, was used for the determination of particular sorption coefficients. During the course of capillary action, the basic thermal parameters, i.e. the thermal conductivity coefficient and the volumetric heat capacity coefficient were measured. A 28-day simulation period was adopted. For both materials, different diversifications of the thermal parameters were identified throughout the partition thickness, with a scale changing along the duration of the capillary flow.
PL
W artykule przedstawiono ocenę stopnia oddziaływania zawilgocenia kapilarnego na parametry cieplne dwóch popularnych materiałów ściennych – cegły ceramicznej i silikatowej. Realizacja tego zadania wymagała przeprowadzenia badań podciągania kapilarnego, które polegały na rejestracji zmieniającej się masy próbek testowanych materiałów, wprowadzonych w kontakt z ciekłą wodą. Odtworzona w odniesieniu do poszczególnych próbek zależność zmiany masy w czasie posłużyła do wyznaczenia składowych współczynników sorpcji. W trakcie procesu podciągania kapilarnego prowadzono równoczesne pomiary podstawowych parametrów cieplnych, tj. współczynnika przewodzenia ciepła i objętościowej pojemności cieplnej. Przyjęty okres symulacji wynosił 28 dni. W przypadku obydwu materiałów stwierdzono odmienne zróżnicowanie wartości parametrów cieplnych po grubości przegrody o skali zmieniającej się wraz z czasem trwania procesu podciągania kapilarnego.
PL
Referat dotyczy procesu sorpcji wilgoci w materiałach budowlanych. Przedstawiono w nim badania związane z wyznaczeniem zawilgocenia sorpcyjnego, zrealizowane na ośmiu różnych materiałach w sześciu odmiennych warunkach cieplno-wilgotnościowych. Testowanymi materiałami były cegła ceramiczna CC, cegła silikatowa CS, cztery betony komórkowe BK1, BK2, BK3, BK4 oraz zaprawa cementowa ZC i cementowo-wapienna ZCW. Badania zrealizowano w temperaturze 5°C oraz przy następujących poziomach wilgotności względnej powietrza: φ≈ 11,3; 33,6; 58,9; 75,7; 87,7; 98,5 %. Próbki materiałów o grubości 1 cm zaizolowano na pobocznicy i wysuszono do stałej masy w temperaturze 105°C. Następnie próbki umieszczano nad nasyconymi roztworami odpowiednich soli stabilizującymi wilgotność względną powietrza na określonym poziomie. W danych warunkach wilgotnościowych znajdowało się po 3 próbki każdego materiału. Badania polegały na rejestracji zmiany masy próbek w określonych odstępach czasu. Pomiary zmiany masy próbek rejestrowano przy użyciu wagi elektronicznej o dokładności 1 mg. Najdłużej ustalała się równowaga sorpcyjna przy wilgotności powietrza bliskiej 100 %. Przeprowadzone pomiary dostarczyły ilościowych danych na temat wielkości zawilgocenia sorpcyjnego w zależności od rodzaju, gęstości materiału oraz warunków cieplno-wilgotnościowych, w jakich materiały się znajdują. Oceniano wpływ wymienionych czynników na wielkość zawilgocenia sorpcyjnego. Wraz ze wzrostem wilgotności względnej powietrza obserwowano wzrost zawilgocenia sorpcyjnego. Jedynie w przypadku cegły ceramicznej nie zanotowano wyraźnych różnic w wielkości tego parametru. Największe wartości uzyskiwano dla betonów komórkowych.
EN
The paper is devoted to the moisture sorption process in building materials. Presented research carried out on eight different materials in six diverse hygrothermal conditions were aimed on determining sorption moisture content. Ceramic brick CC, calcium silicate brick CS, four autoclaved aerated concretes BK1, BK2, BK3, BK4, cement mortar ZC and cement-lime mortar ZCW were tested. The measurements were conducted in temperature of 5°C and in the following levels of air relative humidity: φ ≈ 11.3; 33.6; 58.9; 75.7; 87.7; 98.5 %. The materials samples of 1 cm thickness were insulated on sides and dried up in temperature of 105°C to a constant mass. Subsequently, the samples were placed over saturated salt solutions which were stabilizing air relative humidity at definite level. In given humidity conditions 3 samples of every material were kept. The experiments consisted in recording changes of samples mass in pre-defined time intervals. Measurements of the changing mass of samples were recorded with the electronic scale with accuracy of 1 mg. The sorption equilibrium settled the longest at the relative humidity close to 100%. The carried out measurements provided quantitative data regarding sorption moisture content, depending on material type, material density and hygrothermal conditions. Influence of the factors in question on the value of sorption moisture content was evaluated. With the increase of air relative humidity the increase of sorption moisture content was observed. Merely in case of ceramic brick no distinct differences of this parameter was noted. The highest values were obtained for autoclaved aerated concretes.
EN
In this article, the main goal of conducted experiments was focused on determination of physical and mechanical features of examined sand-lime building blocks and how they interact with each other. The experiment was conducted using solid sand-lime bricks of 250 x 180 x 220 mm size of the class 15 as well as modified products of the same size but different structure. The investigation covered different kinds of fillers. From the preliminary technical and economical analysis we may state that the best ones are barite, basalt, hematite and magnetite.
7
Content available remote Badania odporności ogniowej murów z silikatów
8
Content available remote Analiza zużycia płyt formy cegły wapienno-piaskowej
PL
W pracy przedstawiono analizę zużycia płyt formy cegły wapienno-piaskowej. Nierównomierny rozkład ubytków jest efektem sił tarcia w warunkach przemieszczania się mieszanki wapienno-piaskowej i odpowiednio wysokich nacisków na ścianki form. Podczas formowania wyrobu istniał również nierównomierny rozkład sił prasowania oddziałujących na poszczególne jego elementy. Skutkowało to niejednorodnością zagęszczenia. Potwierdziły to badania gęstości i chłonności wody. Płyty form w miejscu największego zagęszczenia wyrobu posiadały największe zużycie. Mapę zużycia płyt sporządzono na podstawie wyników pomiarów uzyskanych za pomocą maszyny współrzędnościowej Mistral. Wyniki pomiarów zużycia płyt i twardości opracowywano z użyciem programu SigmaPlot.
EN
The paper describes an analysis of the usage of plates of the mould used in the lime-sand, brick production process. Uneven distribution of the material loses was caused by the friction forces created during the movements of the lime-sand mixture and high pressures on the mould walls. During the formation of the product, there was also uneven distribution of pressing forces affecting each element. This caused a heterogeneous density that is proven by the density and water absorption examinations. Mould plates were damaged most in the highest density of product areas. A diagram of the usage of plates was created using the results obtained from the Mistral coordinates measuring machine. The results of the usage of plates and hardness examinations were elaborated with SigmaPlot software.
12
Content available remote Zastosowanie wyrobów silikatowych
13
Content available remote Wyroby silikatowe
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.