EN
The use of cardiac pacemakers (PMs) increases in Western countries. The aim of the study is to investigate cardiac pacemakers (PMs) using a human-shaped phantom in magnetic fields of a shunt reactor at a 400 kV substation. We performed seven PM experiments using a phantom. Two locations close to the shunt reactors were chosen. The magnetic field exposure was over 1000 µT in one location and over 600 µT in the other one. The magnetic field exposure did not disturb the tested five different PMs (in unipolar or bipolar configurations). It can be stated that in our experiment, the magnetic field exposure (over 600 µT and over 1000 µT) did not disturb the PMs (in unipolar or bipolar configurations). Since we only studied some PMs, it is possible that the magnetic field exposure at 400 kV substations can cause disturbances to other PMs. However, the risk of disturbances does not seem to be high.
EN
The paper presents problems of exposing cardiac pacemaker (CPM) and implantable cardioverter defibrillator (ICD) to electromagnetic field. The authors have focused on work environment EMF source - RF dielectric heaters. To investigate if the basic restrictions were exceeded according to IEC reference levels, the interface voltage at the input port of a pacemaker in a full 3D human model and phantom was calculated. The result of calculations was analyzed.
PL
Praca prezentuje problemy związane z ekspozycją stymulatora serca i wszczepialnych kardioweterów defibrylatorów na pole elektromagnetyczne w miejscu pracy. Jako źródło pola elektromagnetycznego w środowisku pracy przedstawiono zgrzewarki dielektyczne wysokiej częstotliwości. Przebadano poziom napięcia indukowanego na wejściu urządzenia. W badaniach symulacyjnych wykonanych z wykorzystaniem metody różnic skończonych w dziedzienie czasu (FDTD) zastosowano ograniczenia ekspozycji implantów narzucone przez międzynarodowe standardy .
PL
Praca prezentuje problemy związane z ekspozycją stymulatora serca na pole elektromagnetyczne w miejscu pracy. Autorzy skupiają się na dwóch rodzajch źródeł: 50/60Hz (napowietrzne linie przesyłowe) oraz 100 MHz - 2 GHz (telefonia komórkowa). Przebadano poziom napięcia indukowanego na .wejściu stymulatora. Badania symulacyjne zostały wykonane z wykorzystaniem metody różnic skończonych w dziedzinie czasu (FDTD). Praca prezentuje wyniki badań przeprowadzonych z udziałem pacjentów ochotników posiadających wszczepione stymulatory serca. Badania te przeprowadzono dla źródła pola elektromagnetycznego w postaci anteny stacji bazowej.
EN
The paper presents problems connected with cardiac pacemaker exposed to electromagnetic field at workplace. The authors have focused on two kinds of sources: 50/60 Hz (overhead power lines) and 100 MHz - 2 GHz (wireless tele-communication). To investigate if the basic restrictions were exceeded accord-ing to IEC reference levels, the interface voltage at the input port of a pace-maker in a full 3D human model was calculated. The numerical investigation of the coupling model i.e. field-to-voltage transfer function, was carried out using FDTD (Finite-Difference Time-Domain) method. The paper presents result of investigation with patient volunteers exposed to electromagnetic field generated by base station antenna.
EN
The role of relaxation oscillator models in application fields such as modeling dynamic systems and image analysis is discussed. A short review of the Van der Pol,Wilson-Cowan and Terman-Wang relaxation oscillators is given. The key property of such nonlinear oscillators, i.e., the oscillator phase shift (called the Phase Response Curve) as a result of external pulse stimuli is indicated as a fundamental mechanism to achieve and sustain synchrony in networks of coupled oscillators. It is noted that networks of such oscillators resemble a variety of naturally occurring phenomena (e.g., in electrophysiology) and dynamics arising in engineering systems. Two types of oscillator networks exhibiting synchronous behaviors are discussed. The network of oscillators connected in series for modeling a cardiac conduction system is used to explain causes of important cardiac abnormal rhythms. Finally, it is shown that a 2D network of coupled oscillators is an effective tool for segmenting image textures in biomedical images.
PL
Artykuł prezentuje problematykę badań stymulatorów serca eksponowanych na sztucznie generowane pole elektromagnetyczne przez systemy telefonii komórkowej. Autorzy koncentrują się na analizie wpływu terminali doręcznych (badania literaturowe) oraz anten bazowych (badania własne). Opisano dokładnie procedurę badawczą in vivo związaną z analizą wpływu anteny bazowej. Przedstawiono wyniki badań oraz wskazówki dla bezpiecznego stosowania kardioimplantów.
EN
The paper presents problems connected with cardiac pacemakers exposed to electromagnetic fields generated by mobile phone systems. The authors concentrate on the influence of hand terminals (literature survey) and base antennas (own research). The research procedure of the latter has been described in detail. The results of research and hints for safe Osage of cardiac pacemakers have been presented.
PL
Praca prezentuje doniesienia wstępne z własnych badań eksperymentalnych nad wpływem pola elektromagnetycznego generowanego przez antenę stacji bazowej na pracę stymulatorów serca. Badania na pilotowej grupie 25 pacjentów - nie wykazały, że praca kardioimplantu przy emisji na wymienione pole elektromagnetyczne ulega zakłóceniu.
EN
These papers presents initial results of own experimental research on influence electromagnetic field - generated by antenna of base station. The investigation hasn't shown that the work of pacemaker can be disturbed.
7
Content available remote Application of fuzzy logic to pacemaker control
EN
A family of efficient fuzzy logic-based control algorithms for rate-adaptive cardiac pacemakers has been developed. They use one or two input signals. The algorithm with one input signal consists of a set of fuzzy rules. For two input signals single signal responses are combined using constant weights. This algorithm offers good adaptation of the pacing rate to the physiological needs of the patient and easy personalization. However, its usefulness depends on the details of practical implementation such as the necessary hardware resources, programmability, accuracy and power consumption. Several hardware implementations were studied, including software emulaton on general purpose low power microprocessors as well as dedicated digital and mixed-mode ASICs, confirming feasibility of practical implementation of the models.