Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  capillary condensation
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Experimental isotherm data obtained for the samples collected from a selected shale gas borehole at the depth from 2803 to 2834 meters for both Argon and Nitrogen analysis at 77.4 K are presented. The results are compared for the mean value of Pore Size Distribution (PSD) using BJH (Barret–Joyner–Halenda) algorithm for desorption curves with application of thickness curve based on Halsey equation and also on Faas correction. Pore Size Distributions (PSD) and their volumes are characterized and compared for both the BJH and DFT (Density Functional Theory) methods.
PL
Przedstawiono eksperymentalne dane izotermiczne otrzymane dla próbek pobranych z wybranego odwiertu w niekonwencjonalnym złożu gazu z głębokości od 2803 do 2834 metrów, dla analizy z użyciem argonu i azotu w temperaturze 77,4 K. Porównano wyniki dla średnich wartości Rozkładu Wielkości Porów (ang. pore size distribution, tj. PSD) używając algorytmu BJH (ang. Barret–Joyner–Halenda) dla krzywych desorpcji z użyciem krzywej grubości zgodnie z równaniem Halsey’a oraz zastosowaniem poprawki Faas. Scharakteryzowano i porównano rozkład wielkości porów (PSD) i odpowiednio zajmowanych przez nie objętości przy użyciu metod BJH i DFT (ang. Density Functional Theory).
EN
Natural gas from shales (NGS) and from tight rocks are one of the most important fossil energy resource in this and next decade. Significant increase in gas consumption, in all world regions, will be marked in the energy sector. The exploration of unconventional natural gas & oil reservoirs has been discussed recently in many conferences. This paper describes the complex phenomena related to the impact of adsorption and capillary condensation of gas-condensate systems in nanopores. New two phase saturation model and new algorithm for search capillary condensation area is discussed. The algorithm is based on the Modified Tangent Plane Criterion for Capillary Condensation (MTPCCC) is presented. The examples of shift of phase envelopes are presented for selected composition of gas-condensate systems.
PL
Gaz ziemny z łupków (NGS) oraz z ze złóż niskoprzepuszczalnych (typu ‘tight’) staje się jednym z najważniejszych zasobów paliw kopalnych, w tym i następnym dziesięcioleciu. Znaczący wzrost zużycia gazu we wszystkich regionach świata zaznacza się głównie w sektorze energetycznym. Rozpoznawanie niekonwencjonalnych złóż gazu ziemnego i ropy naftowej w ostatnim czasie jest omawiane w wielu konferencjach. Niniejszy artykuł opisuje złożone zjawiska związane z wpływem adsorpcji i kapilarnej kondensacji w nanoporach w złożach gazowo-kondensatowych. Pokazano nowy dwufazowy model równowagowy dwufazowy i nowy algorytm wyznaczania krzywej nasycenia w obszarze kondensacji kapilarnej. Algorytm bazuje na kryterium zmodyfikowanym płaszczyzny stycznej dla kapilarnej kondensacji (MTPCCC). Przykłady zmiany krzywych nasycenia są przedstawiane w wybranym składzie systemów gazowo- kondensatowych.
3
Content available Well testing in shale gas reservoir - new idea
EN
Generally hydrocarbons reservoirs can be divided into conventional reservoirs and unconventional reservoirs. Conventional reservoirs belong these reservoirs which can be used directly after the discovering process. Unconventional reservoirs - reservoirs which after the discovery process have to be prepared to be effective. Unconventional gas resources are targets for development in order to contribute to a national energy mix. Better recognition of the unconventional gas reservoirs allow us to obtain good results after discovering them. The main subject of this paper is giving some details about the testing methods of unconventional reservoirs and their properties and characteristics.
4
Content available remote Solvation force for systems in a square-like geometry
EN
The solvation force of a simple fluid confined between four identical walls is studied with different settings of surface fields. Our numerical results, obtained by densitymatrix renormalization techniques for a strip-like systems of widths up to 500 lattice constants, provide excellent the bulk free-energy extrapolation. The influence of surface fields setting on the pseudo-coexistence line and on the solvation force is presented.
5
Content available remote Bulk critical exponents in a presence of the capillary condensation
EN
The properties of a simple fluid or magnet with strong one-axis anisotropy can be studied by means of the Ising model. Such a model, but in an confined geometry with identical boundary fields, is studied along various thermodynamic paths using the density-matrix renormalization group technique. It has been found that also in the presence of the capillary condensation the critical exponent β of the bulk system can be found.
6
Content available remote Kryterium kondensacji pary wodnej na powierzchni przegród według prEN ISO 13788
PL
Zgodnie z wieloletnim przyzwyczajeniem, datującym sie od Hencky'ego (1919), kryterium kondensacji pary wodnej na powierzchni przegród wyraża się w taki sposób, aby temperatura powierzchni była wyższa od punktu rosy powietrza w pomieszczeniu. W rzeczywistości podczas ekspertyz spotyka się kondensację pary wodnej i rozwój pleśni na powierzchniach elementów budynków, których temperatura spełnia po3wyższe kryterium. Wynika to z efektu kondensacji kapilarnej, ktora ma miejsce juz przy wilgotności względnej powietrza równej 80%. Z tego względu w pracach normalizacyjnych CEN zmienia sie kryterium kondensacji pary wodnej. Proponowane zmiany mają uzasadnione fizyczne i są zgodne z doświadczeniem.
EN
In accordance with a long-term tradition dating since Hencky (1919), the criterion i water vapor condensation on internal surfaces is expressed by the condition that suite temperature is higher than dew point for air in a room. In fact, performing expertise1 water vapor condensation and growth of moulds is often noticed on surfaces ofbiii elements, even if temperature of those items fulfills the above criterion. It is an efll capillary condensation, which takes place at RH equal to 80%. Therefore, withr tasks ofCEN, the criterion of water vapor condensation is being changed. The prop changes are physically justified and are in agreement with experiments.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.