Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  capillary action
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Diagnostics and mitigation of excessive moisture effects are some of the most frequent problems in historical buildings. In this article, an attempt was made to measure the moisture content of construction elements in the historical tenement house in Gubin. It is the largest town in the Krosno Poviat, in the area of the Lubuskie Voivodeship. The town suffered from military actions during World War II whereby approximately 90% of its urban development was destroyed. The tenement house at 14A, Śląska Street is one of the more well-preserved buildings, made in the classicist style with characteristic historical features. The whole history of the building is unknown but there are freemasonry symbols on the elevation, and probably the Military Police had its headquarters there after 1945.
EN
The lightweight insulating cement mortars with expanded perlite reveal high porosity bound with the presence of this filler. However, their properties are lowered due to the absorption of water. The studies were performed with aim to improve the composition of cement – perlite mortars and their parameters, such as, density and the percentage of absorbed water by use of admixtures. The three series of mortars of similar consistency were produced with cement to perlite volume ratio of 1/3, 1/5 and 1/7 respectively. The water repellent and air entraining agents were used. The density and water absorption were measured and the observations of microstructure were carried out under SEM. The transport of water in the mortars was significantly slower and limited by use of admixtures. The proportions giving the lowered density at fairly low absorbability complying with the standard requirements have been pointed out. The advantageous effect of water repellent and air entraining agent has been proved.
PL
Lekkie zaprawy ciepłochronne sporządzone z udziałem perlitu ekspandowanego charakteryzują się podwyższoną porowatością, co skutkuje pogorszeniem niektórych właściwości użytkowych w obecności wilgoci. Praca stanowi podsumowanie badań mających na celu poprawę właściwości termoizolacyjnych tworzyw perlitowych poprzez wprowadzenie domieszek o działaniu hydrofobizującym i modyfikującym mikrostrukturę materiału. Sporządzono kilka serii zapraw cementowo-perlitowych o różnej zawartości perlitu. Przeprowadzono pomiary podciągania kapilarnego i standardową ocenę nasiąkliwości. Dokonano obserwacji pod elektronowym mikroskopem skaningowym, podczas których potwierdzono zwartą mikrostrukturę warstwy na granicy rozdziału: wypełniacz perlitowy – matryca cementowa. Ustalono proporcje cement/perlit/domieszka, zapewniające istotne zmniejszenie nasiąkliwości. Wskazano też na korzyści wynikające z zastosowania domieszki hydrofobizującej i napowietrzającej.
EN
This article is about laboratory tests of concretes with 0%, 10%, 20% of the chalcedonite powder. Tested were the effect of the additions on compressive strength, absorbency and capillary strength of concrete. Compression strength was tested after 7, 14, 28, 56 and 90 days. The absorbability and capillary reinforcement of the concretes were tested after 28, 56 and 90 days. For concrete samples with 20% of the powder, the decrease in strength after 90 days of maturation is no more than 5% compared to the non-additive concrete series. In the absorbance test for the tested series with 20% of chalcedonite powder, a loss of weight gain of 11.3% was noted for the non-additive concrete after 90 days of maturation. The longer the concrete matures, the smaller the weight gain in the capillary action test. A similar tendency was noted for the amount of added additive. The more of the additive, the smaller the mass gain in absorbability and capillary action.
PL
Artykuł dotyczy badań laboratoryjnych betonów z dodatkiem 0%, 10%, 20% pyłu chalcedonitowego. Badano wpływ dodatku na wytrzymałość na ściskanie, nasiąkliwość i podciąganie kapilarne betonów. Wytrzymałość na ściskanie badano po upływie 7, 14, 28, 56 i 90 dniach. Nasiąkliwość i podciąganie kapilarne betonów zbadano po upływie 28, 56 i 90 dniach. Dla próbek betonowych z dodatkiem 20% pyłu spadek wytrzymałości po 90 dniach dojrzewania jest nie większy niż 5% w porównaniu do serii betonów bez dodatku. W badaniu nasiąkliwości dla badanej serii z 20% pyłu chalcedonitowego zanotowano spadek przyrostu masy o 11,3% w stosunku do betonu bez dodatku po 90 dniach dojrzewania. Im dłużej beton dojrzewa, tym mniejszy jest przyrost masy w badaniu podciągania kapilarnego. Podobną tendencję zauważono dla ilości wprowadzanego dodatku. Im więcej dodatku, tym mniejszy przyrost masy w nasiąkliwości i podciąganiu kapilarnym.
4
EN
The article discusses the results of laboratory tests on the impact of dolomite mineral dust on the rheological properties of the concrete mix. The addition of mineral dust rise to an overall improvement in the studied parameters (absorption, capillary), by sealing the grout. The impact of their actions on the rheological properties depend largely on the grain composition and the degree of grinding. Rheological properties of concrete mixtures of flours stone depends on the amount and geometrical properties of these additives. The use of additives enforces the need for their treatment by the process of drying, screening and segregation. The effect of the presence of meal stone to change the rheological properties of fresh concrete (density, consistency) and hardened concrete parameters (compressive strength, water absorption, capillary action).
PL
Pracę poświęcono badaniom oddziaływania włókien polipropylenowych na przebieg procesu podciągania kapilarnego w zaprawach cementowych. Wyznaczono współcznynnik sorpcji wody w odniesieniu do sześciu testowanych zapraw cementowych, oceniając wpływ rodzaju i długości włókien PP na ten parametr.
EN
The paper concentrates on the research of the effects of polypropylene fibers on the flow of the process of capillary action in cement mortars. Water sorption coefficients with respect to six tested cement mortars have been determined and impact of the type and length of PP fibers on this parameter have been assessed.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.