Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  capacitive deionization
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
An innovative desalination method called electrosorption or capacitive deionization (CDI) has significant benefits for wastewater treatment. This process is performed by using a carbon fiber electrode as a working electrode to remove hexavalent chromium ions from an aqueous solution. The pH, NaCl concentration, and cell voltage were optimized using the Box-Behnken experimental design (BDD) in response surface methodology (RSM) to study the effects and interactions of selected variables. To attain the relationship between the process variables and chromium removal, the experimental data were subjected to an analysis of variance and fitted with a quadratic model. The optimum conditions to remove Cr(VI) ions were: pH of 2, a cell voltage of 4.3V, and NaCl concentration of 1.4 g/L. This study demonstrated that the carbon fiber electrode was very efficient in Cr(VI) ions removal and the BBD methodology was a practical and effective strategy for predicting the results of various experimental conditions during a CDI process for the removal of chromium ions.
PL
Według prognoz do 2030 roku na świecie nastąpi ograniczenie dostępności wody i będzie wynosiło ok. 40%, natomiast 50% populacji Ziemi pozostanie bez bezpośredniego dostępu do wody pitnej. Dlatego należy podejmować starania mające na celu skuteczniejsze uzdatnianie i większy odzysk wody z możliwych i dostępnych źródeł, często nazywanych potocznie źródłami niekonwencjonalnymi. W artykule przedstawiono dwie metody, które z powodzeniem mogą znaleźć zastosowanie w gospodarce wodą w zakładach przemysłu spożywczego. Pierwszą z nich jest osmoza bezpośrednia (FO), którą można zakwalifikować do membranowych technik rozdziału wykorzystujących istnienie siły napędowej pomiędzy stronami połprzepuszczalnej membrany. Drugą techniką pozwalającą na odsalanie wody jest pojemnościowa dejonizacja (CDI), w której wykorzystano działanie prądu stałego o niskim napięciu na przepływający między elektrodami płyn. Nowe metody oczyszczania wody zapewniają możliwości pozyskiwania tańszej wody zakładom przetwórstwa żywności.
EN
According to forecasts, until 2030 in the world water availability will have limited and it will be compared to about 40%, while 50% of the Earth’s population will remain without access to drinking water. Therefore, efforts should be made to improve water treatment and recovery from possible and available sources, often colloquially called unconventional sources. In this article two methods that can be successfully used in water management in food-processing plants are present. The first is forward osmosis (FO), which can be classified as membrane separation techniques using the existence of a driving force between the sides of the semi-permeable membrane. The second technique which allows water desalination is capacitive deionization (CDI), which uses the effect of low voltage direct on the fluid flowing between the electrodes. New methods of water purification provide the possibility of obtaining cheaper water for food-processing plants.
EN
The removal of dissolved sulphate ions in water is one of the main challenges in the industry. Dissolved sulphate ions are ubiquitous in mining influenced waters because of its physical and chemical stability in aqueous solutions, including in process-water used by mineral beneficiation processes. It is a major problem for the mining industry because it can have negative impacts on the mineral beneficiation process and bring other issues for equipment and piping infrastructure. Not to mention the quality requirements for environmental water release. For instance, when water is recycled to the concentrator plant, dissolved sulphates can build up to increased concentration levels that can have negative effects in the processing of minerals. This work proposes a new approach for the removal of sulphate ions from mining influenced waters, including process water, which is the capacitive deionization technique (CADI). The technique can provide good quality water with low sulphate content suitable for recycling to the beneficiation process and meet adequate quality for recycling and safe release to the environment. Synthetic process-water with sulphate concentrations similar to those in mining and mineral process water was prepared and treated by CADI at fixed conditions of electric current and residence time. The original sulphate concentration in water was 1000, 2000, 3000 mg/L; and reduction rates achieved of sulphate concentrations of 275 mg/L, 712 mg/L and 1015 mg/L. respectively. The results show effective removal of sulphate ions.
PL
Usuwanie uwolnionych jonów siarczanowych w wodzie jest jednym z głównych wyzwań w przemyśle. Uwolnione jony siarczanowe są wszechobecne w wodach będących pod wpływem działań górniczych ze względu na ich fizyczną i chemiczna stabilność w roztworach wodnych, wliczając w to wody procesowe stosowane podczas procesów wzbogacania. Jest to główny problem dla przemysłu górniczego ponieważ ma to negatywny wpływ na proces wzbogacania oraz powodować może także problemy sprzętowe i infrastruktury rurowej. Ponadto, nie należy zapominać o wpływie takiej wody na środowisko naturalne. Dla przykładu, kiedy woda jest kierowana do procesów przeróbczych, uwolnione siarczany mogą się namnażać do poziomów wysokiej koncentracji a to ma negatywny wpływ na prowadzone procesy. Praca ta proponuje nowe podejście do problemu usuwania jonów siarczanowych z przemysłowych wód górniczych, wliczając w to wody procesowe, którym jest zastosowanie dejonizacji pojemnościowej. Technika ta daje dobrej jakości wodę o niskiej zawartości siarczanów, która jest odpowiednia dla procesów wzbogacania i jest zgodna z wymogami jakościowymi dla recyklingu a tym samym bezpieczna dla środowiska naturalnego. Sztuczna woda procesowa o zawartości siarczanów podobnej do wody przemysłowej z zakładów przeróbczych sektora górniczego została przygotowana i poddana procesowi CADI w stałych warunkach napięcia elektrycznego i czasu. Oryginalna koncentracja siarczanów w wodzie wynosiła 1000, 2000, 3000 mg/L a stopień redukcji osiągnięty wyniósł, odpowiednio, 275 mg/L, 712 mg/L oraz 1015 mg/L. Wyniki pokazały efektywność w usuwaniu jonów siarczanowych z wody procesowej.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.