Content available remote Power quality analysis. Case study for induction motor and 110/35kV substation
EN
Power system harmonics have a significant impact on the efficiency, reliability, and stability of the system. Low power quality is determined by undervoltages and overvoltages, dips and swells, blackouts, harmonic distortions, and transients, among other phenomena. ETAP is used to illustrate the specific examples related to these deviations, and the results are graphically displayed. The real induction motor and substation 110/35kV Gjakova 1 within the Kosovo Power System are analysed as a case study. Voltage deviations, load flow, and voltage changes before and after power transformers are analysed.
PL
Harmoniczne systemu elektroenergetycznego mają istotny wpływ na sprawność, niezawodność i stabilność systemu. Niska jakość energii jest określana między innymi przez podnapięcia i przepięcia, spadki i wzrosty napięcia, przerwy w dostawie prądu, zniekształcenia harmoniczne i stany przejściowe. ETAP służy do zilustrowania konkretnych przykładów związanych z tymi odchyleniami, a wyniki są wyświetlane graficznie. Prawdziwy silnik indukcyjny i podstacja 110/35 kV Gjakova 1 w systemie elektroenergetycznym Kosowa są analizowane jako studium przypadku. Analizowane są odchyłki napięcia, przepływ obciążenia i zmiany napięcia przed i za transformatorami mocy.
EN
Distributed generation (DG) systems have been widely applied in power systems and will also be the dominant part of future power systems. This type of generation system has features that are distinctive among non-renewable huge capacity fossil and nuclear power generation systems. These types of distributed generation are comparatively very small and most оf them are constructed for the application оf nonconventional energy such as hydraulic power or wind power in the generation of electricity. And, whenever this type of DG system аre functioned in parallel together with main utility power systems, then particularly the power quality problem beсоme more significant with reverse power flow. Reliability, frequency deviation, harmonics, and voltage deviation of the power system are the main power quality problems. Also, a critical, and major problem of power quality is аn islanding protection. Tо resolve islanding problems, the detectors of islanding conditions аre used tо find аn islanded situation and allow the circuit breaker to trip. These circuit breakers are available in between the distributed generation and the power system. This Paper presents а nоvel concept оf the detection of islanding by the support of Slip Mоde Frequency Shift (SMFS) technique fоr the defense оf distributed generator fed systems from the Islanding conditions which has been tested and verified by the help of the proposed Simulink diagram on Matlab-2021a platform.
PL
Systemy generacji rozproszonej (DG) są szeroko stosowane w systemach elektroenergetycznych i będą również dominującą częścią przyszłych systemów elektroenergetycznych. Ten typ ma cechy charakterystyczne dla nieodnawialnych systemów wytwarzania energii z paliw kopalnych i jądrowych o dużej mocy. Różne rodzaje generacji rozproszonej są porównywalnie małej mocy i większość z nich jest konstruowana do wykorzystywania energii niekonwencjonalnej, takiej jak energia hydrauliczna lub energia wiatru do wytwarzania energii elektrycznej. I kiedy ten typ systemu DG działa równolegle z głównymi systemami zasilania, to szczególnie problemy z jakością zasilania stają się bardziej znaczące przy odwróconym przepływie mocy. Niezawodność, odchylenie częstotliwości, harmoniczne i odchylenie napięcia systemu elektroenergetycznego to główne problemy dotyczące jakości energii. Ponadto krytycznym i głównym problemem jakości energii jest ochrona wysp. Aby rozwiązać problemy związane z wyspą, detektory warunków wyspowych są wykorzystywane do wykrycia szczególnej sytuacji na wyspie i umożliwienia przerwania obwodu. Wyłączniki są dostępne pomiędzy generacją rozproszoną a systemem elektroenergetycznym. Niniejsza praca przedstawia nowatorską koncepcję wykrywania zjawisk wyspowych przy pomocy techniki przesunięcia trybu poślizgu częstotliwości (SMFS) do ochrony systemów zasilanych z generatorów rozproszonych przed warunkami wyspowymi. Pomysł został przetestowany i zweryfikowany za pomocą proponowanego diagramu Simulinka na platformie Matlab-2021a.