The dispersion of pollutants in space around wind engineering structures governed by convection and diffusion mechanism and depends strongly on the velocity field. To understand the phenomena related to the forming of concentration fields it is necessary to recognize the local features of the flow around the objects with the special emphasize for the mean velocity direction, random and periodical fluctuations accompanying the vortex generation in bodies neighbourhood. The specific flow conditions generated around bluff bodies arrangement make it possible to study the gas pollutant dispersion for the case of very complex velocity field typical for built environment. This paper evaluates the performance of computational modelling approach (RANS k-) for two test cases with wind tunnel experiments for validation. The paper presents the results of the complex research program aimed at understanding a character of the flow field in neighborhood of bluff-bodies immersed in a boundary layer and characteristics of pollutants dispersion in that area. The analysis has been performed for the 3D case of two surface-mounted bluff bodies arranged in tandem. The local characteristics of flow and concentration profiles of tracer gas (CO2) for various inter obstacle gaps were obtained by the use of commercial CFD code (FLUENT). Characteristic feature of flow field around groups of buildings in urban areas is high level the unsteady phenomena resulting from itself character of the wind or from the interference of the wake flow connected with a process of vortex shedding. This is the factor affecting process of the dispersion of pollutants in the built-up area acting more complex the mechanism of propagate of small parts explained on the basis of processes of advection and turbulent diffusion.
PL
Rozprzestrzenianie się zanieczyszczeń w przyziemnej warstwie atmosferycznej regulowane jest przez mechanizm dyfuzji i konwekcji oraz silnie zależy od pola prędkości. W celu zrozumienia zjawisk związanych z kształtowaniem się pól koncentracji istotne jest rozpoznanie struktury przepływu wokół obiektów ze szczególnym uwzględnieniem prędkości średniej oraz jej losowej i okresowej składowej towarzyszącym generacji wirów w otoczeniu obiektów naziemnych w obszarach zabudowanych. W pracy przedstawiono wyniki numerycznego modelowania procesu dyspersji zanieczyszczeń gazowych w strefie zabudowanej. Ich celem było określenie wpływu konfiguracji obiektów, stopnia ich "zagłębienia" w warstwie przyziemnej, a także położenia źródła emisji na rozprzestrzenianie się zanieczyszczeń (znacznik gazowy - CO2). Badany układ stanowiły dwa trójwymiarowe modele budynków o różnych wysokościach ustawione w tandemie. Charakterystyki aerodynamiczne przepływu oraz profile koncentracji gazu znacznikowego (CO2) dla różnych konfiguracji obiektów uzyskano z wykorzystaniem komercyjnego oprogramowania FLUENT. Cechą szczególną pól prędkości w otoczeniu grupy opływanych budynków jest wysoki poziom niestacjonarności wynikający zarówno z samego charakteru wiatru, jak i z faktu generowania przez obiekty zjawisk periodycznych związanych z procesem schodzenia wirów. Jest to czynnik, który oddziałuje na proces dyspersji zanieczyszczeń w obszarze zabudowanym, czyniąc jeszcze bardziej złożonym mechanizm rozprzestrzeniania się cząstek tłumaczony na bazie procesów adwekcji i turbulentnej dyfuzji.
The problem of pollution dispersion throughout atmospheric boundary layer has grown in importance since human activity has become so intense that it started having considerable impact on natural environment. The level of concentration of pollutants has escalated, particularly in urban areas and it impacts on their inhabitants. The paper presents the results of the complex research program aimed at understanding a character of the flow field in neighborhood of bluff-bodies immersed in a boundary layer and characteristics of pollutants dispersion in that area. Analysis of gas pollutants dispersion process requires in-depth identification of the structure of flow around the buildings. The analysis has been performed for the 3D case of two in-line surface-mounted bluff bodies, arranged in tandem, which were placed with one face normal to the oncoming flow. The mean concentration profiles of tracer gas (CO2) for various inter-obstacle gaps were measured in wind tunnel. Characteristic feature of flow field around groups of buildings in urban areas is high level the unsteady phenomena resulting from itself character of the wind or from the interference of the wake flow connected with a process of vortex shedding. This is the factor affecting process of the dispersion of pollutants in the built-up area acting more complex the mechanism of propagate of small parts explained on the basis of processes of advection and turbulent diffusion. The local characteristics of flow were obtained by the use of commercial CFD code (FLUENT).
PL
Problem rozprzestrzeniania się zanieczyszczeń w przyziemnej warstwie atmosfery nabrał znaczenia, gdy działalność człowieka stała się na tyle intensywna, że zaczęła wywierać istotny wpływ na stan środowiska naturalnego. Poziom koncentracji zanieczyszczeń nasilony jest zwłaszcza w obszarach zurbanizowanych, oddziałując na jego mieszkańców. W pracy przedstawiono wyniki modelowych badań dotyczących procesu dyspersji zanieczyszczeń gazowych w strefie zabudowanej. Ich celem było określenie wpływu konfiguracji obiektów, stopnia ich "zanurzenia" w warstwie przyziemnej, a także położenia źródła emisji na rozprzestrzenianie się znacznika gazowego (CO2) emitowanego w ich otoczeniu ze źródła skupionego. Analiza procesu dyspersji zanieczyszczeń gazowych wymaga dokładnego rozpoznania struktury przepływu wokół elementów zabudowy. Badany układ typu tandem stanowiły dwa trójwymiarowe modele budynków o różnych wysokościach ustawione w jednej linii. Profile koncentracji gazu znacznikowego (CO2) dla różnych konfiguracji obiektów zmierzono w tunelu aerodynamicznym. Cechą szczególną pól prędkości w otoczeniu grupy opływanych budynków jest wysoki poziom niestacjonarności wynikający zarówno z samego charakteru wiatru, jak i z faktu generowania przez obiekty zjawisk periodycznych związanych z procesem schodzenia wirów. Jest to czynnik, który oddziałuje na proces dyspersji zanieczyszczeń w obszarze zabudowanym, czyniąc jeszcze bardziej złożonym mechanizm rozprzestrzeniania się cząstek, tłumaczony na podstawie procesów adwekcji i turbulentnej dyfuzji. Wykorzystywane w pracy charakterystyki aerodynamiczne opływu budynków uzyskane zostały z wykorzystaniem programu FLUENT.
The dispersion of pollutants in space around wind engineering structures governed by convection and diffusion mechanism and depends strongly on the velocity field. To understand the phenomena related to the forming of concentration fields it is necessary to recognize the local features of the flow around the objects with the special emphasize for the mean velocity direction, random and periodical fluctuations accompanying the vortex generation in bodies neighbourhood. The specific flow conditions generated around bluff bodies arrangement make it possible to study the gas pollutant dispersion for the case of very complex velocity field typical for built environment. The paper presents the results of the complex research program aimed at understanding a character of the flow field in neighborhood of bluff-bodies immersed in a boundary layer and characteristics of pollutants dispersion in that area. The analysis has been performed for the 3D case of two surface-mounted bluff bodies arranged in tandem. The local characteristics of flow and concentration profiles of tracer gas (CO2) for various inter obstacle gaps were obtained by the use of commercial CFD code (FLUENT). Characteristic feature of flow field around groups of buildings in urban areas is high level the unsteady phenomena resulting from itself character of the wind or from the interference of the wake flow connected with a process of vortex shedding. This is the factor affecting process of the dispersion of pollutants in the built-up area acting more complex the mechanism of propagate of small parts explained on the basis of processes of advection and turbulent diffusion.
PL
Rozprzestrzenianie się zanieczyszczeń w przyziemnej warstwie atmosferycznej regulowane jest przez mechanizmy dyfuzji i konwekcji oraz silnie zależy od pola prędkości. W celu zrozumienia zjawisk związanych z kształtowaniem się pól koncentracji istotne jest rozpoznanie struktury przepływu wokół obiektów ze szczególnym uwzględnieniem prędkości średniej oraz jej losowej i okresowej składowej towarzyszącym generacji wirów w otoczeniu obiektów naziemnych w obszarach zabudowanych. W pracy przedstawiono wyniki numerycznego modelowania procesu dyspersji zanieczyszczeń gazowych w strefie zabudowanej. Ich celem było określenie wpływu konfiguracji obiektów, stopnia ich „zanurzenia” w warstwie przyziemnej, a także położenia źródła emisji na rozprzestrzenianie się zanieczyszczeń (znacznik gazowy - CO2). Badany układ stanowiły dwa trójwymiarowe modele budynków o różnych wysokościach ustawione w tandemie. Charakterystyki aerodynamiczne przepływu oraz profile koncentracji gazu znacznikowego (CO2) dla różnych konfiguracji obiektów uzyskano z wykorzystaniem komercyjnego oprogramowania FLUENT. Cechą szczególną pól prędkości w otoczeniu grupy opływanych budynków jest wysoki poziom niestacjonarności wynikający zarówno z samego charakteru wiatru, jak i z faktu generowania przez obiekty zjawisk periodycznych związanych z procesem schodzenia wirów. Jest to czynnik, który oddziałuje na proces dyspersji zanieczyszczeń w obszarze zabudowanym, czyniąc jeszcze bardziej złożonym mechanizm rozprzestrzeniania się cząstek, tłumaczony za pomocą procesów adwekcji i turbulentnej dyfuzji.
The problem of pollution dispersion throughout atmospheric boundary layer has grown in importance since human activity has become so intense that it started having considerable impact on natural environment. The level of concentration of pollutants has escalated, particularly in urban areas and it impacts on their inhabitants. The paper presents the results of the complex research program aimed at understanding a character of the flow field in neighborhood of bluff-bodies immersed in a boundary layer and characteristics of pollutants dispersion in that area. Analysis of gas pollutants dispersion process requires in-depth identification of the structure of flow around the buildings. The analysis has been performed for the 3D case of two in-line surface-mounted bluff bodies, arranged in tandem, which were placed with one face normal to the oncoming flow. The mean concentration profiles of tracer gas (CO2) for various interobstacle gaps were measured in wind tunnel. Characteristic feature of flow field around groups of buildings in urban areas is high level the unsteady phenomena resulting from itself character of the wind or from the interference of the wake flow connected with a process of vortex shedding. This is the factor affecting process of the dispersion of pollutants in the built-up area acting more complex the mechanism of propagate of small parts explained on the basis of processes of advection and turbulent diffusion. The local characteristics of flow were obtained by the use of commercial CFD code (FLUENT).
PL
Problem rozprzestrzeniania się zanieczyszczeń w przyziemnej warstwie atmosfery nabrał znaczenia, gdy działalność człowieka stała się na tyle intensywna, że zaczęła wywierać istotny wpływ na stan środowiska naturalnego. Poziom koncentracji zanieczyszczeń nasilony jest zwłaszcza w obszarach zurbanizowanych, oddziałując na jego mieszkańców. W pracy przedstawiono wyniki modelowych badań dotyczących procesu dyspersji zanieczyszczeń gazowych w strefie zabudowanej. Ich celem było określenie wpływu konfiguracji obiektów, stopnia ich „zanurzenia” w warstwie przyziemnej, a także położenia źródła emisji na rozprzestrzenianie się znacznika gazowego (CO2) emitowanego w ich otoczeniu ze źródła skupionego. Analiza procesu dyspersji zanieczyszczeń gazowych wymaga dokładnego rozpoznania struktury przepływu wokół elementów zabudowy. Badany układ typu tandem stanowiły dwa trójwymiarowe modele budynków o różnych wysokościach ustawione w jednej linii. Profile koncentracji gazu znacznikowego (CO2) dla różnych konfiguracji obiektów zmierzono w tunelu aerodynamicznym. Cechą szczególną pól prędkości w otoczeniu grupy opływanych budynków jest wysoki poziom niestacjonarności wynikający zarówno z samego charakteru wiatru, jak i z faktu generowania przez obiekty zjawisk periodycznych związanych z procesem schodzenia wirów. Jest to czynnik, który oddziałuje na proces dyspersji zanieczyszczeń w obszarze zabudowanym, czyniąc jeszcze bardziej złożonym mechanizm rozprzestrzeniania się cząstek, tłumaczony na podstawie procesów adwekcji i turbulentnej dyfuzji. Wykorzystywane w pracy charakterystyki aerodynamiczne opływu budynków uzyskane zostały z wykorzystaniem programu FLUENT.