Building heating is an indispensable part of people's winter life in cold regions, but energy conservation and emission reduction should also be taken into account during the heating process. This paper provides a concise overview of the heating system based on air-source heat pump radiant floor and its control strategy. It also optimizes a control system based on thermal comfort and energy efficiency ratio, and analyzes a room in Xining City, Qinghai Province, to test the heating system performance under two control strategies. The final results show that under the traditional control strategy, the cumulative working time of the heating system within a day was 15 hours, the average indoor temperature was 17.36℃, the temperature standard deviation was 2.08℃, and the average power consumption was 189.6 kWh. Under the improved control strategy, the cumulative working time of the heating system within a day was reduced to 10 hours, the average indoor temperature was 18.56℃, the temperature standard deviation was 0.92℃, and the average power consumption was 132.5 kWh.
PL
Artykuł prezentuje wyniki analizy wpływu zawilgocenia cegły ceramicznej na współczynnik przewodzenia ciepła i wskazuje na problem, jakim jest oddziaływanie zawilgocenia przegród zewnętrznych na zmianę temperatury wewnętrznej powierzchni przegrody i wielkość strat ciepła. Wzrost stopnia zawilgocenia przegrody powoduje wzrost wartości współczynnika przenikania ciepła, co wpływa bezpośrednio na obniżenie temperatury wewnętrznej powierzchni ściany zewnętrznej i odczucia cieplne użytkowników budynków oraz na temperaturę operatywną. Dodatkowo w razie obniżenia temperatury powierzchni ściany poniżej temperatury punktu rosy występuje wykroplenie się wilgoci na powierzchni ściany, co przy braku prawidłowo działającej wentylacji prowadzi do rozwoju grzybów pleśniowych. Chcąc zapobiec wystąpieniu w analizowanym budynku negatywnych skutków niekorzystnego obniżenia temperatury przegrody, zaproponowano docieplenie ścian od zewnątrz. Po dociepleniu budynku konieczna jest modernizacja istniejącej instalacji grzewczej i dopasowanie jej do nowych, obniżonych wartości strat ciepła. Zaproponowano nowe wielkości grzejników oraz nowe źródło ciepła.
EN
The article presents the results of an analysis of the effect of moisture on the heat transfer coefficient of a clay brick, and points out the problem of how moisture in the building envelope affects the change in the temperature of the internal surface of the wall and the amount of heat loss. An increase in the amout of moisture content of the building material results in a higher value of the thermal conductivity coefficient, which causes an increase in the heat transfer coefficient and thus also in the transmission heat loss of the building. A higher value of heat transfer coefficient has a direct effect on lowering the temperature of the inner surface of the exterior wall, which has a significant impact on the thermal sensations of building occupants by affecting the operative temperature. In addition, when the wall surface temperatureis lower than the dew point temperature, moisture condensation occurs on the wall surface, which, in the absence of properly functioning ventilation, leads to the development of mold. In order to prevent the occurrence in the analyzed building of the negative effects of an unfavorable decrease in the temperature of the partition, it was proposed to insulate the walls from the outside. After insulating the walls, it is necessary to modernize the existing installation and adjust it to the new reduced heat loss values of the building. New radiator sizes and a new heat source have been proposed.
PL
Rosnące ceny paliw (węgla, gazu, oleju opałowego) oraz energii elektrycznej skłaniają coraz częściej inwestorów do analizy ekonomiczno-technicznej poprzedzającej wybór optymalnego źródła ciepła w modernizowanych obiektach. Oprócz takich aspektów jak chociażby dostępność paliwa, jego cena, czynnikami które odgrywają dużą rolę przy wyborze nowego źródła ciepła do obiektu są możliwości uzyskania dofinansowania inwestycji oraz przede wszystkim obniżenie kosztów eksploatacyjnych związanych z ogrzewaniem obiektu. Biorąc pod uwagę powyższe czynniki coraz większą popularnością wśród inwestorów cieszą się sprężarkowe oraz gazowe absorpcyjne pompy ciepła. W przypadku źródeł ciepła o znacznej mocy obsługujących budynki użyteczności publicznej dobrym rozwiązaniem jest zastosowanie absorpcyjnych pomp ciepła zasilanych gazem. W niniejszym artykule przybliżono technologię gazowych absorpcyjnych pomp ciepła oraz przedstawiono przykłady modernizacji i optymalizacji źródła ciepła z zastosowaniem takich urządzeń.
EN
The rising prices of fuels (coal, gas, heating oil) and electricity increasingly encourage investors to undertake a deep economic and technical analysis prior to selecting the optimal heating source in the modernized facilities. Aside from aspects such as the accessability of fuel and its price, the factors that play a large role in choosing a new heating source for a facility are: the possibility of obtaining funding for investment and, above all, reducing operating costs related to heating the facility. Considering the mentioned factors, a compressor and gas absorption heat pumps are becoming more and more popular among investors. In the case of heat sources of significant power serving public buildings, a good solution is to use gas-fired absorption heat pumps. This article presents the technology of gas absorption heat pumps and presents examples of modernization and optimization of a heating source based on such devices.
EN
The article describes the criteria for assessing the methods of accounting for the costs of thermal energy used by housing communities and cooperatives based on the indications of divisors. The most common errors in the current practice of settlements were pointed out, causing the heating costs to be overstated, calculated as a fee for heating 1 m2 of usable space or for a calculation unit of consumption. The aim of the publication is to present the methods of settling individual costs in a multi-room building, which allow for logical and fair division of the costs of heat supplied to the building for the heating of individual premises in accordance with Polish regulations. The principles of accounting for energy costs after the amendment to the Energy Law and the implementation of the provisions of the Regulation of the Minister of Climate and Environment of December 7, 2021 on the conditions for establishing the technical feasibility and profitability of using heat meters, heat cost allocators and water meters for measuring domestic hot water were discussed, as were the conditions for selecting the method of accounting for the purchase costs of heat and the scope of information contained in individual settlements.
EN
In this paper we present the analysis of the gas usage for different types of buildings. First, we introduce the classical theory of building heating. This allows the establishment of theoretical relations between gas consumption time series and the outside air temperature for different types of buildings, residential and industrial. These relations imply dierent auto-correlations of gas usage time series as well as different cross-correlations between gas consumption and temperature time series for different types of buildings. Therefore, the autocorrelation and the cross-correlation were used to classify the buildings into three classes: housing, housing with high thermal capacity, and industry. The Hurst exponent was calculated using the global DFA to investigate auto-correlation, while the Kendall's τ rank coeficient was calculated to investigate cross-correlation.
PL
W artykule przedstawiono wyniki badań eksploatacyjnych dwóch budynków mieszkalnych wielorodzinnych (budynek A oraz budynek B), w których zastosowano zawory termostatyczne. Budynek A miał 100 mieszkań o łącznej powierzchni ogrzewanej 4 933 m2, natomiast budynek B 40 mieszkań o łącznej powierzchni ogrzewanej 2 532 m2. Badania polegały na comiesięcznym pomiarze zużycia ciepła dostarczanego do analizowanych budynków na potrzeby centralnego ogrzewania przez odpowiednio - budynek A - 7 sezonów grzewczych, budynek B - 8. Porównując zużycie ciepła budynku przed i po zastosowaniu zaworów termostatycznych, uwzględniono odpowiednie współczynniki korekcyjne, aby otrzymać niezależne od temperatury zewnętrznej wyniki potrzebne do oceny skuteczności dokonanej modernizacji systemu ogrzewczego. Zwrócono uwagę na średni sezonowy poziom oszczędności uzyskiwanych dzięki zastosowaniu zaworów termostatycznych oraz podano uzyskiwane oszczędności ciepła w poszczególnych miesiącach sezonu ogrzewczego. Artykuł został opracowany na podstawie materiałów konferencyjnych II Studenckiej Konferencji Ogólnobudowlanej Budmika 2015 na Politechnice Poznańskiej, 22-24 kwietnia 2015 r.
EN
The article presents the results of field tests of two multifamily residential buildings (building A and building B), where thermostatic valves have been applied. Building A had 100 apartments with a total heated area of 4 933 m2, while the B building - 40 apartments with a total heated area of 2 532 m2. The study consisted of monthly consumption measurement of heat delivered to the analyzed buildings: for central heating of building A - 7 heating seasons and for building B - 8 seasons. Comparing the heat consumption of the building before and after the application of thermostatic valves, correction factors were taken into account in order to receive the results needed to assess the modernization effectiveness of the heating system independent on the outside temperature. Attention was drawn to the average seasonal level of savings achieved with the use of thermostatic valves and heat savings achieved in each month of heating season are given. The article was prepared on the basis of conference materials of II Student Conference on General Construction Budmika 2015 Poznan University of Technology, 22-24 April 2015.
PL
W artykule przedstawiono analizę pracy instalacji centralnego ogrzewania i przygotowania ciepłej wody użytkowej zasilanej gazowym kotłem kondensacyjnym. Wyznaczono sprawność instalacji odbiorczych w okresie od 1.11.2012 r. do 31.10.2013 r. – wyniosła ona 83,5%. Przedstawiono dwie metody uwzględnienia wpływu warunków klimatycznych na wskaźnik zużycia energii. Przeanalizowano wskaźnik zużycia energii pierwotnej w badanym okresie. Zaproponowano formułę opisującą sprawność całkowitą w zależności od zużycia energii pierwotnej (gazu).
EN
In this article the job analysis of central heating installation and the preparation of the domestic hot water supplied with the gas condens-ing boiler is presented. Between 1.11.2012 and 31.10.2013 installations operation was examined and there was 83,5% efficiency achieved. Two methods which use the climatic parameters to the energy consumption factor are presented. The indicator of the consumed primitive energy in the examined period is analyzed. The describing net efficiency depending on the consumption of energy of fuel (gas) formula is proposed.
PL
W artykule omówiono specyfikę ogrzewania hal wielkokubaturowych, a także główne cechy systemów grzewczych i podstawowe zasady ich projektowania. Przedstawiono cechy elementów konstrukcyjnych promienników rurowych i ich wpływ na koszty urządzeń i jakość działania. Omówiono znaczenie sprawności promienników, szczególnie sprawności radiacyjnej (czyli współczynnika promieniowania i sposób jego określania) Zwrócono też uwagę na brak precyzji przy jego podawaniu oraz powstające przez to zamieszanie na rynku instalacyjnym.
EN
This paper presents the discussion of the specifics of heating of large space buildings, as well as the main features of the heating systems and basic principles of design. The paper covers the characterization of structural components of the radiant tube heaters, their relevance to the cost of the devices and performance. The influence of the heaters efficiency, especially the radiation efficiency i.e. radiant factor is discussed. The method of determining of radiant factor is also presented. The description is particularly focused on the lack of the precision in his administering and resulting confusion in the installation industry.
EN
In this article a technical and economic analysis was performed concerning the use of different types of boilers for combustion of biomass such as straw boiler, boiler for burning wood chips and boiler with a burner for oats. Technical analysis of the boiler covered: power selection, estimation of the seasonal demand for final energy for examplary residential building. Calculated final energy consumption helped to determine the area of cereal crops whose straw and oats will be used as well as the surface of Miscanthus and rose multiflorum. Economic analysis based on life cycle cost method allowed to choose the heat source, which will be the most efficient in economic terms in assumed period of operation. The use of the boiler for combustion of straw will be the best solution. It is characterized by the lowest costs in the case of burning straw bales as well as the use of Miscanthus. The use of boiler burning wood chips combustion generates a cost comparable to Miscanthus. The use of boiler combustion grain oats, which would be specially manufactured for use for energy purposes is not economically justified. Heating costs in this case are 3.5 times higher in comparison with straw burning boiler and double in the case of using the combustion boiler chips. Assuming energy plantations depending on the species, there may be two types of heat source, i.e. boiler burning bales of Miscanthus or automatic set to burn wood chips of rose multiflorum.
PL
Wykonano analizę techniczno-ekonomiczną wykorzystania różnych typów kotłów do spalania biomasy, takich jak: kocioł na słomę, kocioł do spalania zrębków oraz kocioł z palnikiem na owies. Analiza techniczna objęła dobór mocy kotła, oszacowanie sezonowego zapotrzebowania na energię końcową dla przykładowego budynku mieszkalnego. Obliczone zużycie energii końcowej posłużyło do określenia powierzchni uprawy roślin zbożowych, z których będzie wykorzystana słoma oraz ziarno owsa a także powierzchnię miskanta olbrzymiego i róży wielokwiatowej. Analiza ekonomiczna oparta na metodzie kosztów cyklu życia pozwoliła wybrać źródła ciepła, które w założonym okresie eksploatacji będą najbardziej efektywne pod względem ekonomicznym. Najlepszym rozwiązaniem będzie zastosowanie kotła do spalania słomy. Charakteryzuje się on najniższymi kosztami w przypadku spalania balotów słomy jak również w przypadku zastosowania miskanta olbrzymiego. Zastosowanie kotła spalającego zrębki generuje koszty porównywalne spalania miskanta olbrzymiego. Zastosowanie kotła spalającego ziarno owsa, które byłoby specjalnie produkowane z przeznaczeniem na cele energetyczne jest ekonomicznie nieuzasadnione. Koszty ogrzewania w tym przypadku są 3,5-krotnie wyższe w porównaniu z kotłem spalającym słomę i dwukrotnie wyższe w przypadku zastosowania kotła spalającego zrębki. Przy założeniu plantacji roślin energetycznych w zależności od gatunku, można zastosować dwa rodzaje źródła ciepła: kocioł spalający baloty miskanta olbrzymiego lub automatyczny zestaw do spalania zrębków róży wielokwiatowej.
PL
Działania Unii Europejskiej dotyczące gospodarki energetycznej zmierzają do zmniejszenia emisji CO2 do atmosfery oraz do wzrostu udziału energii, uzyskiwanej ze źródeł odnawialnych, w całkowitym zużyciu energii. Jako konsekwencję tych działań planuje się w przyszłości ograniczenie, a w dalszej perspektywie wycofanie z użycia systemów ogrzewania gazowego, olejowego i węglowego w budownictwie. Alternatywą dla tego typu instalacji są rozwiązania wykorzystujące energię elektryczną. Artykuł przedstawia koncepcję budowy systemu hybrydowego, opartego o ceramiczny akumulator ciepła, jako sposób wykorzystania tej energii do celów ogrzewania dla budownictwa jednorodzinnego. Wypełnienie akumulatora ogrzewane jest w nocy za pomocą grzałek elektrycznych. Hybrydowa funkcja systemu realizowana jest przez powietrze chłodzące wypełnienie, kontaktujące się w wymienniku ciepła z wodą przepływającą w instalacji centralnego ogrzewania. W pracy zaprezentowano koncepcję instalacji badawczej. Pokazano wyniki badań eksperymentalnych przeprowadzonych na opisywanym stanowisku. Ponadto wskazano cele i perspektywy planowanych prac badawczych.
EN
The European Union energy management tends to reduce CO2 emission and to increase the share of energy obtained from renewable energy sources in total energy consumption. As a consequence of these actions there are plans of reduction and eventually elimination of natural gas, oil and coal usage in building heating. The paper presents accumulative systems with ceramic bed as an alternative method of heating. Moreover the experimental setup of this system is explained in details. The measurement technology, data acquisition and visualization is also discussed in this paper. The sample measurement results are shown and the possibility of extending the functionality of experimental setup is discussed.
PL
W artykule omówiony został sposób przygotowania systemów kominowych i wentylacyjnych, zarówno na etapie projektowania, jak i wykonania. Podane zostały tabele, na podstawie których można dobrać optymalną średnicę komina w stosunku do rodzaju spalanego paliwa oraz mocy pieca lub kotła grzewczego. Jak zaznacza autor, nie jest dobrym montaż średnic zarówno większych jak i mniejszych niż optymalne. Jednak nawet najlepiej dobrana średnica przewodu nie pomoże, jeśli komin nie będzie odpowiednio często czyszczony i serwisowany.
EN
This articles explains how to prepare the chimney and ventilation systems, both in the design and execution. These are the tables from which to choose the optimal diameter of the chimney in relation to the type of fuel burned and the power of the furnace or boiler. As the author is not a good fitting both larger diameter and less than optimal. But even the best matched the diameter of the cable will not help if the chimney is not properly cleaned and serviced frequently.
PL
W artykule zaprezentowano możliwości wykorzystania niskotemperaturowych wód geotermalnych do celów ciepłowniczych. Analiza potencjału energetycznego wód została wykonana dla otworów geotermalnych zlokalizowanych w gminie Kamienica Polska i gminie Poczesna, których średnia temperatura wody wynosi ok. 19,5°C. W dalszej części arty-kułu przedstawiono koncepcję ciepłowni geotermalnej, wykorzystującej wody niskotemperaturowe, zaopatrującej w ciepło pobliskie budynki użyteczności publicznej. Do celów analizy wybrany został otwór badawczy w gminie Poczesna (woj. śląskie) o samoczynnym wypływie 24 m3/h i średniej temperaturze wody równej 19,5 °C. Dla istniejącego otworu zapropo-nowano dwa układy ciepłowni z pompą grzejną: monowalentny i biwalentny. Analiza kosztów eksploatacyjnych wykazała, że proponowana ciepłownia geotermalna może stanowić alternatywę dla konwencjonalnych ciepłowni w przypadku gdy system ciepłowniczy zostanie skojarzony z systemem wodociągowym.
EN
In this paper the concept of low temperature goethermal heat-generating plant and its utilization for heating buildings was presented. For the analytical purposes the authors have chosen existing drilled well located in Poczesna and Kamienica Polska communities with average geothermal water temperature at 19,5 °C. For the analytical purposes the authors have chosen existing drilled well located in Poczesna community with average geothermal water temperature at 19,5 °C and 24 m3/h spontaneous outflow volume flux. For existing well the monovalent and the bivalent low temperature geothermal heating system with heat pump was taken into consideration. The operating cost analysis has shown that proposed geothermal heating plant could be an alternative for fossil fuel fired heating plant only in a case of combining heating system with water supply.
PL
W pracy przedstawiono rezultaty analizy termodynamicznej układu rurowego gruntowego wymiennika ciepła, w którym podgrzewane (chłodzone) jest powietrze. Powietrze jest następnie wykorzystywane w systemie wentylacji budynku. Wymiennik ciepła składający się z sześciu równoległych rur zainstalowany jest w wierzchniej warstwie górotworu. Rozpatrywany jest okres jednego roku działania urządzenia. W pracy przedstawiono i porównano rezultaty obliczeń dla różnych parametrów geometrycznych gruntowego wymiennika ciepła.
EN
This paper presents the results of thermodynamic analysis of the tubular heat exchanger for air heating up. This air is used in building ventilation systems. The heat exchanger is installed in the upper part of ground and consists of six parallel pipes. The period of one year is taken into consideration. This paper presents and compares calculation results for various geometric parameters of ground heat exchanger.
15
Content available remote Smart buildings versus ground energy and indoor technologies
EN
It is argued that heat pumps as one of renewable energy sources are very energy efficient, and therefore environmentally-friendly. Under favourable conditions, the energy from low-potential heat, in other way unusable, is used as a source of energy for a heat pump performance. The applicability of this system supports the utilisation of electric energy at a low tariff rate, which is also valid for the operation of other electrical appliances. This article determines operative production costs for heating and operation of other electrical appliances and indicates new ways of using it in combination with low-temperature heating systems.
PL
Pompy ciepła, jako źródło energii odnawialnej, są bardzo efektywne energetycznie i z tego powodu przyjazne dla środowiska naturalnego. W dobrych warunkach energia pozyskiwana ze źródła dolnego, nieużyteczna w inny sposób, jest efektywnie wykorzystywana za pośrednictwem pompy ciepła. Używanie takiego systemu może być dodatkowo atrakcyjne przez zastosowanie taniej taryfy energii elektrycznej. To dotyczy również użytkowania innych urządzeń elektrycznych. W artykule określono koszty ogrzewania i użytkowania innych urządzeń elektrycznych i wskazano nowe sposoby ich stosowania w kombinacji z niskotemperaturowymi systemami ogrzewania.
PL
W artykule przedstawiono obliczenia pól temperatury w stanach nieustalonych dla przegród budowlanych jedno i dwuwarstwowych, złożonych z materiałów o różnych dyfuzyjnościach. Dokonano obliczeń dynamiki podłogi grzejnej, przy różnym usytuowaniu przewodów grzejnych i różnej grubości warstwy akumulacyjnej. Zwrócono uwagę na wpływ zmian warunków zewnętrznych na zmiany temperatur ścian. Określono straty cieplne przez ścianę zewnętrzną budynku przy stałej mocy generowanej przez podłogę grzejną.
EN
In the paper temperature fields calculations were presented in non-steady state for one- and multi-layer structure, using materials with assorted thermal diffusivity. Computations of heating floor dynamics were made, with different thickness of storage heat elements and different depth of location heating cable.
PL
Opisano jedną z metod racjonalizacji zużycia energii na potrzeby cieplne budynku, ogrzewanie z przerwami, na przykładzie rzeczywistego obiektu użyteczności publicznej (biura zlokalizowanego w Białymstoku). Porównano wartości uzyskane z obliczeń teoretycznych wykonanych na podstawie obowiązującej normy EN 832: 1998 z wielkościami rzeczywistymi uzyskanymi w trakcie pomiarów. Zaakcentowano celowość wdrażania opisanej metody w budynkach niemieszkalnych.
EN
The one rationalisation method out of many, concerning energy consumption for building heating purpose, is described. The method is based on an intermittent heating. A public service building (an office located in Bialystok) has been taken as an example of a real object. The results of theoretic calculations, carried out on the basis of the valid EN 832: 1998 Standard, are compared with the real values of the measurement. The usefulness of the implementation of the method in non-residential buildings, as described in the paper, is emphasised.
18
Content available remote Zarządzanie ryzykiem wystąpienia ostrej zimy
PL
Jednym z problemów podczas ogrzewania budynku jest ustalenie mocy zamówionej. W przedstawionym przykładzie znaleziono taką wartość, która obniża opłaty za ciepło w sezonie ogrzewczym, lecz zwiększa ryzyko niedogrzania w czasie ostrej zimy. W celu redukcji ryzyka zaproponowano utworzenie depozytu bankowego zabezpieczającego odbiorcę. Jeżeli najbliższa zima będzie łagodna, to odbiorca całkowicie zredukuje ryzyko niedogrzania. W przedstawionym przykładzie pokazano, że można obniżyć koszty ogrzewania od 2,5% do 9% rocznie.
EN
One of problems for district heating heat consumer is placing an order for maximum quantity of heat required. In presented example a value that decreases costs of heating, but raises risk of heating less than required at low outside door air temperatures, was found. In order to reduce risk a safe-deposit was proposed. If next winter will be mild, the safe-deposit completely reduces risk. In presented example heating cost can be reduced from 2.5% to 9% per year.
19
Content available remote Termomodernizacja: studium korzyści
PL
Pojęcie „termomodernizacja” nie zawsze kojarzy oszczędność z coraz droższą energią. Wielu utożsamia ją z dociepleniem zewnętrznych lub wewnętrznych ścian budynku, a przecież takie uproszczenie prowadzi zwykle do przykrych niespodzianek i braku oczekiwanych efektów.