Content available remote Using BIM to select the most energy-efficient insulation materials
EN
This paper presents the application of BIM in energy modeling (BEM) processes. Examples from the literature demonstrating the validity of using BIM in energy simulation and analysis are presented, pointing out the benefits of these applications, which include energy efficiency, facilitating innovative design solutions, sustainability-oriented design and environmental protection, as well as the creation of comprehensive construction documentation. In order to investigate the usefulness of BIM and BEM technologies in the selection of energy-efficient, environmentally friendly building materials, energy analyses were performed in Archicad software with the built-in Energy Evaluation tool. The results, obtained in the form of reports, allow, among other things, the estimation of the annual energy demand necessary for heating the studied building and the cost of this energy. The purpose of the analyses was to select the most energy-efficient insulation material, hence a review of the insulation materials available on the market and their parameters was carried out.
PL
W artykule przedstawiono zastosowanie BIM w procesach modelowania energetycznego budynków (BEM). Zaprezentowano w nim przykłady z literatury pokazujące zasadność stosowania BIM w symulacjach i analizach energetycznych, wskazując korzyści płynące z tych zastosowań, do których zalicza się efektywność energetyczną, wprowadzenie innowacyjnych rozwiązań projektowych, projektowanie zorientowane na zrównoważony rozwój i ochronę środowiska, a także tworzenie kompleksowej dokumentacji budowlanej. W celu zbadania przydatności technologii BIM i BEM w doborze energooszczędnych, przyjaznych środowisku materiałów budowlanych wykonano analizy energetyczne w programie Archicad z wbudowanym narzędziem Energy Evaluation. Wyniki uzyskane w formie raportów pozwalają m.in. oszacować roczne zapotrzebowanie na energię niezbędną do ogrzania badanego budynku oraz koszt tej energii. Celem analiz był wybór najbardziej energooszczędnego materiału izolacyjnego, dlatego też dokonano przeglądu dostępnych na rynku materiałów izolacyjnych i ich parametrów.
PL
W literaturze pojawiają się różnego rodzaju kontrowersje na temat polskiej Metodologii wyznaczania charakterystyki energetycznej budynków. Zauważalny jest problem rozbieżności obliczeń i wyników pomiarów. W niniejszym artykule porównano obliczoną charakterystykę energetyczną budynków dla 5 gospodarstw domowych zlokalizowanych w budynkach jednorodzinnych, wg obowiązującej Metodologii lub jej modyfikacji, ze zmierzonym wykorzystaniem energii. Analiza miała na celu sprawdzenie czy występują rozbieżności wyników i co jest ich przyczyną. Czy różnice wynikają z niedokładności uproszczonego, statycznego modelu cieplnego budynku, tzw. metody miesięcznej, czy są raczej związane z warunkami brzegowymi: zarówno danymi meteorologicznymi, tzw. typowym rokiem meteorologicznym, jak i innymi parametrami opisującymi użytkowanie zarówno instalacji grzewczej, jak i ciepłej wody użytkowej. Okazało się, że rozbieżności w analizowanych budynkach jednorodzinnych wynikają głównie z założeń odnośnie do ich użytkowania, które w obecnej formie Metodologii są z góry narzucone. Narzucanie warunków brzegowych może wydawać się celowe w przypadku porównywania różnych rozwiązań technicznych, ale jednocześnie powoduje rozdźwięk między rzeczywistym wykorzystaniem energii a obliczeniowym, co skutkuje spadkiem zaufania do świadectwa charakterystyki energetycznej. Dlatego należy przemyśleć ponownie idę Metodologii i jej użyteczność zarówno dla projektantów, konsumentów jak i dla twórców polityki energetycznej kraju.
EN
There are various controversies in the literature about the Polish Methodology for determining the energy performance of buildings. The problem of discrepancy between calculations and measurement results is noticeable. This paper compares the calculated energy performance of buildings of 5 households located in single-family houses, according to the current Methodology or its modifications, with the measured energy use. The analysis aimed to show if there is a discrepancy in the results and what is the reason for it. Do the discrepancies result from inaccuracies of the simplified, static thermal model of the building, the so-called monthly method, or are they rather linked to the boundary conditions: both the meteorological data, typical meteorological year, and other parameters describing the use of the heating system as well as the domestic hot water system. We found that the discrepancies for the analyzed single-family houses are mainly due to assumptions on their use, which are enforced in the current form of the Methodology. The enforcement of boundary conditions may seem to be appropriate when comparing different technical solutions, but at the same time it causes a discrepancy between the actual energy use and the calculated one, which results in a decrease of trust towards the energy performance certificate. Therefore, it is necessary to rethink the idea of the Methodology and its usefulness for designers, consumers and national energy policy makers alike.
PL
Metody wyznaczania charakterystyki energetycznej budynków powinny być weryfikowane, aby mogły być skutecznym narzędziem w procesie opracowywania energooszczędnych rozwiązań oraz aby pomagały w kształtowaniu polityki energetycznej. W niniejszym artykule porównano zbiór obliczonych wartości z Centralnego rejestru charakterystyki energetycznej budynków z wartościami zmierzonymi w budynkach poddawanych termomodernizacji, opublikowanymi przez GUS, a także danymi oszacowanymi we współpracy przez GUS i Rząd RP. Analiza wykazała, że wartości szacunkowe i obliczeniowe zaniżają średnie wykorzystanie ciepła na cele grzewcze. Średnie zmierzone wykorzystanie ciepła jest o 12% większe niż średnie obliczone i o 5% większe niż oszacowane. Natomiast rozrzut wartości zmierzonych jest 2,3 razy większy niż rozrzut wartości obliczonych. Wykazano również, że dla analizowanej bazy danych budynków termomodernizowanych średnie wykorzystanie ciepła spadło na skutek termomodernizacji o 25%, a rozrzut wartości rocznego wykorzystania ciepła 1,6 razy. Ninijeszy artykuł potwierdza tezę, że obecna Metodologia wymaga ciągłej i systemowej weryfikacji lub zastąpienia innymi narzędzami gwarantującymi wzrost krajowej efektywności energetycznej.
EN
Methods for determining the energy performance of buildings should be verified so that they can be an effective tool in the process of developing energy-efficient solutions and be helpful in shaping energy policy. This paper compares the set of calculated values from the Polish Central Energy Performance of Buildings Registry with the values measured in buildings before and after thermal renovation, published by the Statistics Poland, as well as the data estimated by cooperation of the Statistics Poland and the Polish Government. The analysis showed that estimated and calculated values understate the average energy consumption for heating purposes. The mean measured energy consumption is 12% and is 5% higher than the mean calculated energy consumption and the estimated energy consumption respectively. The dispersion of measured values is 2.3 times larger than the dispersion of calculated values. It was also shown that, acc. to the analyzed database of thermally renovated buildings, the mean energy consumption of thermally renovated buildings decrease by 25% and the dispersion of annual energy consumption values decrease 1.6 times. This paper confirms the thesis that the current Polish methodology of building energy performance calculation needs a continuous and systematic verification or replacement by other tools guaranteeing the increase of national energy efficiency.