Constantly deteriorating condition of the natural environment directly affects the need for widespread use of ecological solutions. The concept of pro-ecological architecture should embrace not only housing but also public facilities, including educational buildings. The purpose of the article is to analyze the architecture of selected educational objects with an ecological certificate in terms of the form, function, materials and land development. To what extent the architecture of the building affects the certification result? The article uses literature, LEED and BREEAM guidelines, and comparative analyzes of selected objects.
PL
Stale pogarszający się stan środowiska naturalnego wpływa bezpośrednio na potrzebę powszechnego stosowania ekologicznych rozwiązań. Koncepcja architektury proekologicznej powinna obejmować nie tylko zabudowę mieszkaniową ale także użyteczności publicznej, w tym budynki edukacyjne. Celem artykułu jest przeanalizowanie architektury wybranych obiektów edukacyjnych, posiadających certyfikat ekologiczny, pod kątem formy, funkcji, zastosowanych materiałów czy zagospodarowania terenu. W jakim stopniu architektura budynku wpływa na wynik certyfikacji? W artykule wykorzystano analizy literaturowe, wytyczne LEED i BREEAM oraz analizy komparatywne wybranych obiektów.
PL
Wentylacja mechaniczna może być wykonana jako centralna lub zdecentralizowana. Stosowanie systemów centralnych wymaga dużej ilości miejsca na prowadzenie kanałów oraz sporych nakładów finansowych (projekt i wykonanie). Alternatywą może się stać system wentylacji zdecentralizowanej, np. mini centrale ścienne z wymiennikami do odzysku ciepła lub jednorurowe systemy wentylacyjne z ceramicznym wymiennikiem akumulacyjnym do odzysku ciepła. Obecnie zastosowanie tych urządzeń jest ograniczone z uwagi na niespełnienie przez zintegrowaną czerpnio-wyrzutnię ścienną wymagań warunków technicznych [16] odnośnie do wzajemnej lokalizacji otworów czerpni i wyrzutni. W artykule przedstawiono przykładową budowę i zasadę działania rekuperatorów ściennych, przeprowadzono przegląd przepisów prawa pod kątem możliwości ich stosowania oraz omówiono wyniki badań mających na celu ocenę mieszania się strumieni powietrza nawiewanego i wywiewanego w tego typu urządzeniach. Wyniki badań pokazują, że do zawracania powietrza wywiewanego do pomieszczenia nie dochodzi w trakcie typowej pracy tych urządzeń. Z kolei ich stosowanie może zapewnić właściwą jakość powietrza, szczególnie w budynkach już istniejących, a zatem powinny być one zdaniem autorów dopuszczone do powszechnego stosowania jako niezbędne do osiągnięcia standardu budynków nZEB.
EN
Mechanical ventilation can be constructed as centralized or decentralized system. The use of central systems requires a large amount of space for conducting channels and large financial expenses (design + implementation). An alternative might be a decentralized ventilation system might be an alternative, eg mini wall-units with heat exchangers or one-pipe ventilation systems with a ceramic heat exchanger. Currently, their use is limited, due to the failure of the integrated wall intake-outlet element to meet the requirements of the technical conditions [16] regarding the mutual location of those. This article presents the construction and principle of operation of wall recuperators, a review of the polish law in terms of their applicability and discusses the results of tests to assess the mixing of supply and exhaust air streams in an integrated intake-outlet element. The test results show that during typical operation of the devices there the air does not go back to the room. In turn, their use can ensure proper air quality, especially in existing buildings, and therefore they should be approved for general use according to the authors.
PL
Na zużycie energii w budynkach użyteczności publicznej, szczególnie w obiektach edukacyjnych, w dużym stopniu wpływa wentylacja. Wynika to z dużego zapotrzebowania na świeże powietrze z uwagi na dużą liczbę użytkowników. Stosowanie wentylacji mechanicznej z odzyskiem ciepła w tego typu obiektach jest zatem uzasadnione ekonomicznie i ekologicznie. W nowoprojektowanych szkołach, żłobkach, przedszkolach czy salach wykładowych można na etapie projektu przewidzieć miejsce na instalację urządzeń wentylacji mechanicznej centralnej lub zdecentralizowanej. W obiektach już istniejących podczas ich termomodernizacji, znacznie łatwiejsze i tańsze może okazać się zastosowanie systemu wentylacji zdecentralizowanej w postaci niezależnych urządzeń dla każdego z pomieszczeń. W takiej sytuacji dobrym rozwiązaniem są mini-centrale wentylacyjne ścienne ze zintegrowaną czerpnio-wyrzutnią montowaną na zewnętrznej ścianie budynku. Jest to rozwiązanie powszechnie stosowane w budynkach edukacyjnych w Austrii czy Niemczech, ale niepraktykowane w Polsce z uwagi na wymagania prawne Warunków Technicznych jakim powinny odpowiadać budynki i ich usytuowanie (WT) odnośnie do lokalizacji czerpni względem wyrzutni. Intencją tych wymagań jest niedopuszczenie do zawracania powietrza wywiewanego z powrotem do pomieszczenia. W konsekwencji jednak wiele istniejących budynków pozbawia się w ten sposób możliwości poprawy jakości powietrza wewnętrznego i dostarczenia odpowiedniej ilości powietrza zewnętrznego. W niniejszym artykule przedstawiono wyniki badań doświadczalnych mających na celu ocenę mieszania się strumieni powietrza wywiewanego i nawiewanego w zintegrowanych czerpnio-wyrzutniach dwóch typów urządzeń wentylacji zdecentralizowanej przeznaczonych do zastosowania głównie w budynkach edukacyjnych (ale nie tylko). Wyniki badań pokazują, że mieszanie się strumieni powietrza w tych urządzeniach nie występuje. Z kolei możliwość filtracji powietrza, odzysku ciepła oraz dostosowania strumienia powietrza wentylacyjnego do aktualnych potrzeb (np. w funkcji obciążenia pomieszczenia ditlenkiem węgla, parą wodną lub w zależności od liczby osób) pozwala na poprawę jego jakości oraz komfortu klimatycznego przy realnie niskich kosztach. Ponadto urządzenia tego typu mogą być łatwo zastosowane w budynkach już istniejących, ponieważ nie wymagają instalacji systemu dystrybucji powietrza, co skłania do przemyśleń odnośnie do aktualności i zasadności istniejących wymagań prawnych.
EN
The consumption of energy in public buildings, especially in educational ones, is largely influenced by ventilation. This results from the high demand for fresh air due to the large number of users. The use of mechanical ventilation with heat recovery in this type of buildings is, therefore, economically and ecologically justified. In the newly designed schools, nurseries, kindergartens or lecture buildings, a place for the installation of central or decentralized mechanical ventilation systems can be planned at the design stage. In the already existing buildings it may be much easier and cheaper to use a decentralized ventilation system in the form of independent devices for each room during their thermomodernisation. In such a case a good solution are wall ventilation mini units with an integrated air intake / exhaust device mounted on the external wall of the building. It is a solution widely used in educational buildings in Austria or Germany, but not practiced in Poland due to the legal requirements of the technical conditions which should correspond to buildings and their location (WT) regarding the location of air intakes and exhausts. The intention of these requirements is to prevent the exhaust air from being returned to the room. As a consequence, many existing buildings are deprived of the possibility of improving the quality of the indoor air and the possibility to provide an adequate amount of fresh air. In this article, experimental studies have been carried out to assess the mixing of exhausted and fresh air streams in integrated air intake / exhaust devices of two types of decentralized ventilation units dedicated for use mainly in educational buildings (but not only). The results show that the mixing of air streams in these devices does not occur. In turn, the possibility of air filtration, heat recovery and adaptation of the ventilation air flow to the current needs (in the function of room load of carbon dioxide, steam or depending on the number of people) allows to improve air quality and climate comfort. In addition, devices of this type can be easily used in existing buildings, because they do not require the installation of an air distribution system, which makes us think about the timeliness and legitimacy of the existing legal requirements.
PL
Przedstawiono wybrane wyniki badań związanych z rocznym zużyciem energii CH i rocznym zapotrzebowaniem na energię końcową Qk,H do ogrzewania budynków, przeprowadzonych w grupie budynków edukacyjnych. Przedstawiona analiza i jej wyniki dotyczą grupy obejmującej 46 z 50 budynków edukacyjnych, które tworzą miejską grupę budynków tego typu i w których znajdują się instytucje edukacyjne. Celem zaprezentowanej analizy było stwierdzenie występowania różnic pomiędzy rocznym zużyciem energii CH i rocznym zapotrzebowaniem na energię końcową Qk,H dla ogrzewania badanych budynków. Realizacja tego celu stanowi podstawę do dalszych badań i analiz pozwalających wskazać dominujące przyczyny wspomnianych różnic, ustalić ich poziom i zaproponować obliczeniową metodę zmniejszania niezgodności między rzeczywistymi wartościami obrazującymi potrzeby energetyczne budynków edukacyjnych (zużycie energii CH) a teoretycznymi wartościami uzyskanymi z obliczeń (końcowe zapotrzebowanie na energię Qk,H).
EN
This work presents the selected results of examinations connected with an annual energy consumption CH and annual final energy demand Qk,H for heating and conducted on the group of educational buildings. The presented analysis and its results regard the group including 46 of 50 educational buildings, which form a municipal group of the buildings of this type and in which the educational institutions are located. The purpose of presented analysis was to examine the influence of possible occurrence and level of differences between the annual energy consumption CH and annual final energy demand Qk,H for heating of examined buildings. The realization of this purpose is the basis for further research and analysis aimed at determining the dominant reasons of mentioned differences, establishing their level and propose a calculative method for reducing the differences between the values “picturing” the thermal needs of educational buildings in actual (energy consumption CH) and theoretical (final energy demand Qk,H) conditions.
PL
Wartość zużycia energii w rozpatrywanej grupie budynków edukacyjnych zlokalizowanych na terenie miasta Częstochowa różniła się od wyznaczonego obliczeniowego zapotrzebowania na energię końcową do ogrzewania, wentylacji i przygotowania ciepłej wody użytkowej. W artykule przedstawiono analizę czynników, które mają wpływ na kształtowanie się zarówno jednej, jak i drugiej wielkości. Spośród parametrów mających wpływ na rzeczywiste i obliczeniowe wartości strat i zysków ciepła w analizie uwzględniono wskaźniki odnoszące się do powierzchni okien, współczynniki przenikania ciepła dla przegród, zwartość bryły budynku, zacienienie i osłonięcie elewacji, usytuowanie budynku w stosunku do stron świata, ilość powietrza wymienianego w procesie wentylacji oraz liczba osób przebywających w pomieszczeniach. Przedstawiono zależności pomiędzy poszczególnymi parametrami a zapotrzebowaniem i zużyciem energii do ogrzewania, wentylacji i przygotowania ciepłej wody.
EN
The paper presents energy consumption for heating and domestic hot water preparation in educational buildings located in the city of Czestochowa. Because the value of energy consumption in buildings is different from the calculated final energy demand for heating, ventilation and domestic hot water preparation, the factors which have an impact of both of these parameters were analysed. Among the indicators affecting the actual and calculated values of heat losses and gains, the analysis includes indicators referring to the window area, heat transfer coefficients for partitions, the shape factor of the building, façade-shading, shielding the facade from the wind, location of the building in relation to the sides of the world, amount of air exchanged in the ventilation process and the number of people staying in the rooms. The relationships between selected parameters and the demand and energy consumption for heating, ventilation and hot water preparation are presented.
PL
W artykule przedstawiono funkcję okien w budynku pod kątem kształtowania stanu mikrośrodowiska wnętrz i warunków komfortu cieplnego przebywających w nich osób. Zaprezentowano wymagania w tym zakresie, zawarte w warunkach technicznych. Omówiono wyniki badań przeprowadzonych w budynkach edukacyjnych. Przedmiotem analizy była ocena stanu warunków komfortu cieplnego osób przebywających w salach lekcyjnych. Analizę przeprowadzono pod kątem wpływu powierzchni okien sal lekcyjnych w odniesieniu do powierzchni tych sal na kształtowanie się odczuć cieplnych osób w nich przebywających. Badania prowadzono w grupie uczniów oraz w grupie nauczycieli.
EN
The article presents the function of the windows in the building in terms of created the state of the microenvironment in the interiors and the comfort conditions of their occupants. The requirements in this area, included in the technical conditions were presented. The results of research conducted in educational buildings were discussed. The subject of the analysis was the assessment of the people thermal comfort condition in the classrooms. The analysis was made in terms of the influence of the windows area of classroom in relation to the surface of these rooms on the thermal sensations of the persons staying there. The study was conducted in a group of students and in a group of teachers.
PL
Bakterie z rodzaju Legionella są uznawane za jedne z groźniejszych przenoszonych drogą wodną organizmów chorobotwórczych, które wywołują ciężkie schorzenia układu oddechowego. Celem niniejszej pracy była ocena jakości wody w budynku edukacyjnym na podstawie występowania bakterii z rodzaju Legionella oraz wartości parametrów fizyko-chemicznych wody zimnej i ciepłej wody użytkowej. Próbki wody zimnej i ciepłej wody użytkowej (c.w.u.) pobierano do badań z 10 punktów czerpalnych w trzech seriach pomiarowych w okresie pięciu miesięcy. W badanych próbkach analizowano podstawowe parametry fizyko-chemiczne jakości wody tj. pH, przewodnictwo, temperatura, twardość, zasadowość, zawartość węgla ogólnego i nieorganicznego, stężenie azotanów(V), chlorków i siarczanów a także stężenie wapnia, magnezu, żelaza, manganu i cynku. Metodą hodowlaną oznaczano bakterie z rodzaju Legionella. Jakość wody instalacyjnej nie budziła zastrzeżeń i spełniała kryteria zawarte w obowiązującym Rozporządzeniu Ministra Zdrowia (Dz.U. 2015, poz. 1989). Jedynie temperatura wody zasilającej i powrotnej w instalacji c.w.u. nie spełniała obowiązujących przepisów, gdyż była niższa niż wymagana. Spośród przeprowadzonych trzech serii badawczych na przestrzeni 5 miesięcy, bakterie z rodzaju Legionella zostały wykryte jedynie w trakcie serii nr 1 w 80% próbkach c.w.u. Stopień skolonizowania instalacji określono jako wysoki do bardzo wysokiego. W próbkach wody nie wykryto obecności najbardziej niebezpiecznej L. pneumophila sg 1. We wszystkich próbkach Legionella – pozytywnych wykryto szczepy oznaczane jako L. pneumophila sg 2–14. Wymagało to podjęcia działań naprawczych w postaci dezynfekcji termicznej instalacji. Jej skuteczność potwierdziły wyniki badań w kolejnych seriach nr 2 i 3.
EN
Legionella are known as one of the dangerous water-borne pathogens, causing severe respiratory tract infections. The aim of this study was to assess the installation water quality in an educational building located in Lublin on the basis of Legionella sp. concentration and physicochemical parameters of cold and hot installation water. Samples (n=60) of cold and hot water were collected for testing from the 10 tapping points during three surveys over a period of five months. The test samples were analyzed for the basic physicochemical parameters of the water quality such as pH, electrical conductivity, temperature, hardness, alkalinity, the total carbon content, the concentration of nitrates, chlorides and sulphates. Additionally, the concentration of calcium, magnesium, iron, manganese and zinc were examined. The presence of Legionella in water samples was measured according the standard methods. The quality of the analyzed water did not raise objections and met the criteria of the Ordinance of the Polish Ministry of Health (2015, pos.1989). The only parameter which did not comply with applicable regulations was the temperature of the supply water and return hot water – it was lower than required. Bacteria of the genus Legionella were detected only in the hot water samples from series 1 when the rate of colonization reached the level of 80%. Among the positive samples, 2 contained less than 1000 CFU/100 ml, 4 samples contained 1x103 to 1x104 CFU/100 ml, and 2 samples contained more than 1x104 CFU/100 ml. The maximum number of CFU in a sample was 1.8x104/100 ml. The most dangerous serogroup L. pneumophila sg 1 was not detected in any of the positive isolated samples. All Legionella – positive samples belonged to L. pneumophila sg 2–14. These findings necessitated a corrective action in the form of thermal disinfection system and its maintenance. Its effectiveness was confirmed by the results of the survey of 2 and 3.
PL
Projekt KODnZEB ma na celu podniesienie poziomu wiedzy polskich ekspertów w dziedzinie modernizacji istniejących budynków użyteczności publicznej do standardu budynków o niemal zerowym zużyciu energii pierwotnej. Jednym z budynków analizowanych, jako studium przypadku jest gmach Wydziału Instalacji Budowlanych, Hydrotechniki i Inżynierii Środowiska Politechniki Warszawskiej. Artykuł opisuje pomiary przeprowadzone w 32 pomieszczeniach o różnym przeznaczeniu (ok. 20% z 163 pomieszczeń, w których realizowany jest proces nauczania). Pomiary prowadzono w ciągu 10 dni w okresie wiosennym, przy zmiennych warunkach atmosferycznych (temperatura powietrza zewnętrznego zmieniała się w zakresie od 6,6 do 18,7°C). Poważne problemy z mikroklimatem zostały zidentyfikowane w pracowniach komputerowych. Ponadto analiza wykazała, że pomieszczenia położone na południowych i zachodnich elewacjach są zdecydowanie częściej przegrzewane. W salach wykładowych i audytoriach obserwowano podwyższone stężenia CO2 sięgające 2500 ppm. Najwyższe stężenia drobnych frakcji pyłu (PM10, PM2,5 i PM1) zaobserwowano w pomieszczeniach laboratoryjnych oraz w magazynie bibliotecznym. Podwyższone stężenia pyłu zaobserwowano także w pomieszczeniach, w których podłogi były pokryte wykładziną dywanową oraz audytoriach, w których intensywnie wykorzystywano czarne tablice i kredę. Przeprowadzone pomiary wykazały, że koncepcja modernizacji analizowanego budynku do standardu nZEB powinna uwzględniać nie tylko technologie zmierzające do oszczędności energii, ale również przedsięwzięcia poprawiające jakość środowiska wnętrz.
EN
The project KODnZEB aims to improve knowledge of Polish experts in the field of technologies used during modernization of public buildings to nearly zero-energy standard. One of the case study buildings is Faculty of Building Services, Hydro and Environmental Engineering at Warsaw University of Technology. The paper describes measurements carried out in 32 rooms of different character (approx. 20% of 163 rooms where the teaching process is realized). The measurements were performed during 10 days in spring when weather was variable (the range of outdoor temperature from 6.6 to 18.7°C). Serious problems with microclimate were identified in computer rooms. Moreover, the analysis indicated that rooms located at southern and western façades are more extensively overheated. CO2 concentrations up to 2500 ppm were measured in teaching auditoria. The highest concentrations of fine dust (PM10, PM2,5 and PM1) were observed in laboratories. Increased concentrations of dust were monitored in rooms with carpets as well as in rooms with extensive use of black boards and chalk. The performed measurements indicated that modernization concept should take into account not only energy saving innovations, but also should substantially improve indoor air parameters.
EN
This work presents the selected results of examinations connected with an annual energy consumption CH and annual final energy demand Q k,H for heating and conducted on the group of educational buildings. The presented analysis and its results regard the group including 46 of 50 educational buildings, which form a municipal group of the buildings of this type and in which the educational institutions are located. The purpose of presented analysis was to examine the influence of possible occurrence and level of differences between the annual energy consumption CH and annual final energy demand Q k,H for heating of examined buildings. The realization of this purpose is the basis for further research and analysis aimed at determining the dominant reasons of mentioned differences, establishing their level and propose a calculative method for reducing the differences between the values “picturing” the thermal needs of educational buildings in actual (energy consumption C H) and theoretical (final energy demand Q k,H) conditions.
PL
W pracy zaprezentowano wybrane wyniki badań zbiorowości budynków edukacyjnych związane z rocznym zużyciem energii CH i rocznym zapotrzebowaniem na energię końcową do ogrzewania Q k,H . Przedstawiona analiza i jej wyniki dotyczą grupy 46 spośród 50 budynków edukacyjnych tworzących miejską zbiorowość obiektów tego typu, w których mieszczą się placówki oświatowe. Celem zaprezentowanej analizy było identyfikacja i zbadanie poziomu różnic pomiędzy rocznym zużyciem energii CH i rocznymi zapotrzebowaniem na energię końcową Q k,H do ogrzewania badanych budynków. Osiągnięcie wymienionego celu stanowi podstawę do dalszych badań i analiz zmierzających do ustalenia dominujących przyczyn wspomnianych różnic, określenia ich poziomu i zaproponowania sposobu obliczeniowego zmniejszenia różnic pomiędzy wielkościami „obrazującymi” potrzeby cieplne budynków edukacyjnych w warunkach rzeczywistych (zużycie energii CH) i teoretycznych (zapotrzebowanie na energię końcową Q k,H).
EN
The article presents impact of chosen parameters on heat consumption in educational buildings. It was created the analysis of selected architectural, material and construction indexes of educational buildings from the point of view of their influence on energy consumption per heated surface in the year. The general characteristic of evaluated buildings was presented. The analysis includes the value of basic architectural features and thermal transmittance for external partitions. The figures describe the connection between the heat consumption and thermal transmittance value for walls, the amount of energy used to heat buildings and thermal transmittance value for roofs, energy consumption and thermal transmittance value for floors on the ground and heat consumption and shape coefficient.
PL
W artykule przedstawiono wpływ wybranych parametrów na zużycie ciepła w budynkach edukacyjnych. Dokonano analizy parametrów architektoniczno-budowlanych i materiałowo-konstrukcyjnych budynków z punktu widzenia ich wpływu na zużycie energii na metr kwadratowy powierzchni ogrzewanej w ciągu roku. Przedstawiono charakterystykę ocenianych budynków. Analiza obejmowała wartości podstawowych parametrów architektonicznych, współczynniki przenikania ciepła przegród, straty ciepła, wskaźniki zużycia i zapotrzebowania na energię oraz sposoby ogrzewania budynków. Wykresy przedstawiają związek pomiędzy zużyciem ciepła w ocenianych budynkach edukacyjnych a współczynnikami przenikania ciepła ścian, stropodachów, stropów nad piwnicami oraz podłóg na gruncie. Analizie poddano również wpływ współczynnika zwartości budynków oraz wad i usterek przegród na zużycie ciepła.
PL
W artykule przedstawiono zobowiązania podjęte przez Polskę w ramach UE dotyczące zwiększenia efektywności energetycznej, zaprezentowano przeciętne roczne zużycie energii końcowej na ogrzewanie budynku w Polsce oraz maksymalne wartości współczynników przenikania ciepła obowiązujące w Polsce w różnych okresach. Omówiono rodzaj i poziom wymagań cieplno-energetycznych dla budynków edukacyjnych. Wskazano zakres działań możliwych do podjęcia w celu poprawy efektywności energetycznej w budynkach szkół.
EN
The article presents the commitments made by Poland in the European Union for increasing energy efficiency, includes average annual final energy consumption for heating in Poland and maximum values of heat transfer coefficients applicable in Poland at different times. Discusses the type and level of thermal requirements for educational buildings. Indicate areas of possible actions to take to improve energy efficiency in school buildings.
PL
W artykule zaprezentowano aktualne wymagania dotyczące izolacyjności cieplnej i oszczędności energii oraz przedstawiono poziomy izolacyjności przegród w istniejących budynkach edukacyjnych i ich energochłonność. Wskazano możliwość dostosowania struktury do obowiązujących wymagań.
EN
The article presents the current requirements for thermal insulation and energy savings and partition insulation levels in existing educational buildings and their energy consumption. Indicated the possibility of adapting these structure to existing requirements.
PL
W artykule zaprezentowano poziom zużycia energii w budynkach obecnie oraz jego przewidywany wzrost do roku 2030. Wskazano podstawowe cechy budynków, które mają wpływ na zużycie energii. Przedstawiono obszar badań oraz korzyści płynące z kompleksowej analizy zbiorowości obiektów tworzących funkcjonalną, organizacyjną i administracyjną całość.
EN
The article presents energy consumption in buildings today and its projected growth for 2030. It points out the basic features of buildings, which have an impact on energy consumption. It shows the area of research and the benefits of a comprehensive analysis of the collectivity of objects forming a functional, organizational and administrative whole.
EN
This paper presents the selected results of examinations connected with a seasonal heat consumption (Q) and thermal power (q) for heating in educational buildings. The purpose of the analysis presented here was to examine the influence of possible occurrence and level of differences between the seasonal heat consumption (Q) and the seasonal heat demand (Qq) for heating, calculated on the basis of q values. A modification in the method for determination of Qq for room heating on the basis of available data on q was introduced. A linear function, describing the changes in (Qq – Q) depending on the changes in q values, which was applied for that purpose, made it possible to improve the consistency of obtained heat demand values in relation to measured consumption of heat for heating by 65.6%.
PL
W artykule przedstawiono wybrane wyniki analiz związanych z sezonowym zapotrzebowaniem na ciepło (Q) i mocą szczytową (q) do ogrzewania budynków edukacyjnych. Celem tej analizy było ustalenie wystąpienia różnic pomiędzy sezonowym zużyciem ciepła (Q) a sezonowym zapotrzebowaniem na ciepło (Qq) do ogrzewania, obliczonym na podstawie znanej wartości szczytowej mocy cieplnej q. Realizacja ww. analizy stanowiła podstawę do zaproponowania zmiany w metodzie obliczania wartości zapotrzebowania na ciepło Qq do ogrzewania pomieszczeń na podstawie dostępnych danych. Wykorzystanie tutaj funkcji liniowej opisującej zmiany (Qq – Q) w zależności od zmian wartości q umożliwia zmniejszenie rozbieżności pomiędzy obliczonymi wartościami zapotrzebowania na ciepło a zmierzonym zużyciem ciepła do ogrzewania o 65,6%.
PL
Omówiono problematykę zużycia ciepła w obiektach edukacyjnych, przy czym obiektem była grupa 50 budynków edukacyjnych zlokalizowanych na terenie Częstochowy. Badania podzielono na dwa etapy. W artykule przedstawiono wyniki I etapu badań, w którym przeprowadzono analizę energetyczną kilku grup budynków szkolnych. Następnie, wybrano budynek reprezentatywny każdej grupy, w których określono teoretyczne wartości mocy cieplnej oraz zapotrzebowanie na ciepło. Celem badań było stworzenie narzędzia do oceny dużej grupy obiektów o zbliżonych cechach architektoniczno – funkcjonalnych.
EN
In this work the problem of heat consumption in educational facilities. The study was In this work the problem of heat consumption in educational facilities. The study was conducted on a group of 50 educational buildings located in the city of Czestochowa. The study was divided into two stages. This paper presents the first stage of the study. In the first stage of the study subjects were analyzed energy school buildings, which were divided into several groups. Then, for each group of selected building representative for whom the theoretical values of thermal power and heat demand. The aim of this study was to provide a tool for the evaluation of a large group of objects with similar characteristics architectural – functional.
PL
W artykule przedstawiono wyniki badań i analizy zmian sezonowej energochłonności ogrzewania 18 budynków edukacyjnych (szkół) w trzech podobnych sezonach grzewczych. Są one fragmentem szerszych badań staty-stycznych cech 50 budynków szkół w Częstochowie, które wpływają na ich parametry cieplno-energetyczne. Analiza gra-ficznego przebiegu wielkości związanych bezpośrednio lub pośrednio z zużyciem ciepła do ogrzewania powinna być po-mocna w ujawnieniu istniejących zależności i możliwości interpretacyjnych. Przedstawiona propozycja analizy zużycia ciepła do ogrzewania oraz interpretacja jej wyników może posłużyć jako narzędzie w zarządzaniu energią w użytkowanych budynkach, wskazując jednocześnie możliwości racjonalizacji w tym zakresie dla całej zbiorowości i indywidualnych obiektów.
EN
The paper presents the results of the research and analysis of changes of the seasonal energy-consuming for heating in 18 educational buildings (school) for three similar heating seasons. They are some fragment of the results of the statistical research included 50 school buildings in Czestochowa, which affect their thermal-energy parameters. The analysis of graphical course quantity, directly or indirectly associated with the consumption of heat for heating should be helpful in disclosing of existing the relationships and possibilities of interpretation. The presented proposal for analysis of energy consumption for heating and the interpretation of the results can be used as a tool for energy management in buildings used, indicating the possibility of rationalization in this area, for the whole community and individual objects.
PL
W artykule wykorzystano wyniki badań własnych prowadzonych w budynkach edukacyjnych. Dla scharakteryzowania systemów centralnego ogrzewania w badanych budynkach poddano analizie kilka cech zasadniczych dla systemu ogrzewania. Zaliczono do nich: rodzaj źródła zasilania w ciepło instalacji centralnego ogrzewania, eksploatację instalacji, wyposażenie systemu centralnego ogrzewania w urządzenia i automatykę regulacyjną, charakterystykę źródła ciepła w kotłowniach własnych oraz eksploatację indywidualnego źródła ciepła.
EN
This paper describes central heating systems in the studied educational buildings. The analysis considers a few basic features of a heating system. They include: the type of power source, exploitation and equipment of central heating system and characteristics of the heat source.
PL
W artykule scharakteryzowano potencjalne efekty energetyczne i ekonomiczne obniżenia sezonowego zużycia ciepła i tym samym kosztów ogrzewania lokalnej grupy budynków edukacyjnych dzięki ograniczeniu strat ciepła przez przegrody zewnętrzne tych obiektów. Przedstawiono propozycję wykorzystania oszczędności w wybranych budynkach do finansowania działań zmierzających do zmniejszenia sezonowego zużycia ciepła do ogrzewania innych obiektów.
EN
The article describes energy and economic potential effects thanks to the reduction of heat losses through external partitions, the decrease of the seasonal use of heat for heating purposes and reducing the costs of heating a local group of educational buildings.
PL
W referacie przedstawiono wyniki badań w zakresie dotyczącym sezonowego zużycia ciepła Q do ich mocy ogrzewania i mocy szczytowej q. i możliwości poprawy efektywności źródeł ciepła wykorzystywanych do ogrzewania zbiorowości budynków edukacyjnych.
EN
This paper presents the results of the research of the seasonal heat demand for heating Q and heat power q and possibilities of energy effectiveness improvement of heat sources used for heating, in community of educational buildings.
PL
W artykule przedstawiono wyniki badań sezonowego zużycia ciepła Q do ich ogrzewania i mocy szczytowej q w zbiorowości budynków edukacyjnych. Badaniami statystycznymi objęto 50 budynków szkół w Częstochowie zarządzanych przez Urząd Miasta. Na podstawie zebranego pierwotnego materiału badawczego w artykule przedstawiono analizę wpływu wybranych rozwiązań architektoniczno-funkcjonalnych budynków edukacyjnych na rzeczywiste zużycie ciepła do ich ogrzewania.
EN
The paper presents the results of the research of the seasonal heat demand for heating Q and heat power q in the educational buildings. The statistical research included 50 school buildings in Częstochowa governed by the Częstochowa Municipal Office. The paper present analysis of the influence selected architectural and functional solutions of educational buildings on the real seasonal consumption of heat used for heating of this buildings.