Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  biodegradowalne powłoki polimerowe
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Titanium alloys are currently widely used in implantation, especially in orthopaedics. However, undesirable reactions caused by aluminium and vanadium ions released from the surface of the most commonly used alloys, Ti6Al4V and Ti6Al7Nb, result in the need to modify the surface of the material to improve biocompatibility. Among the available modification methods, one can mention the application of biodegradable polymer coatings, which, apart from improving biocompatibility by limiting the penetration of alloying element ions into the tissue environment, can also be a matrix for the release of mineral (HAp) and active substances. The paper attempts to determine the mechanical properties of PLGA polymer coatings containing nanoparticle hydroxyapatite and an active substance (dexamethasone) applied with the ultrasonic spray coating method on a Ti6Al7Nb alloy substrate. The scope of the research included: surface topography testing using an optical profilometer, coating adhesion testing to the substrate using the scratch test method and tribological testing (Pin-On-Disc method).
PL
Stopy tytanu znajdują obecnie szerokie zastosowania implantacyjne, szczególnie w ortopedii. Jednakże niepożądane reakcje wywoływane przez jony glinu i wanadu uwalnianie z powierzchni najczęściej wykorzystywanych w praktyce stopów Ti6Al4V oraz Ti6Al7Nb skutkują koniecznością modyfikacji powierzchni materiału w celu poprawy biokompatybilności. Wśród dostępnych metod modyfikacji wymienić można nakładanie biodegradowalnych powłok polimerowych, które poza poprawą biokompatybilności poprzez ograniczenie przenikania jonów pierwiastków stopowych do środowiska tkankowego stanowić mogą także matrycę dla uwalniania substancji mineralnych (HAp) oraz aktywnych. W pracy podjęto próbę określenia własności mechanicznych powłok polimerowych z PLGA, zawierających nanocząsteczkowy hydroksyapatyt oraz substancję aktywną (deksametazon), nakładanych metodą natryskiwania ultradźwiękowego na podłoże ze stopu Ti6Al7Nb. Zakres przeprowadzonych badań obejmował badania topografii powierzchni z wykorzystaniem profilometru optycznego, badania adhezji powłok do podłoża metodą scratch test oraz badania tribologiczne (metoda Pin-On-Disc).
EN
The aim of this study was to determine the influence of long-term exposure of Ringer’s solution on degradation of the anodically oxidated Ti6Al4V alloy coated with a biodegradable polymer coating. Polymeric coatings made of poly(glycolide-ε-caprolactone) – G-Cap and poly(glycolide- ε-caprolactone-lactide) – G-Cap-L were applied by a dip-coating method. Degradation was assessed on the basis of the results of pitting corrosion resistance and density of metal ions infiltrating to the solution. Studies were conducted for samples after 3, 6, 8, 10 and 12 weeks of exposure to the corrosive environment. In addition, topography of the surface of the polymer coating was assessed. As a result of potentiodynamic studies, the value of the polarization resistance and corrosion potential for the G-Cap and G-Cap-L coated samples were significantly decreased while simultaneous reduction of the density of metal ions infiltrating to the solution throughout the whole study period. There was also observed a faster degradation of the G-Cap coating compared to G-Cap-L, which showed local discontinuity after 12 weeks of exposure. The obtained results provide the basis for the development of polymeric coatings on surface of metal implants with predictable time / kinetics of degradation by selecting the composition of polymers while simultaneous limitation of metal ions infiltration into surrounding tissues.
PL
Celem pracy było określenie wpływu długotrwałego oddziaływania rozworu Ringera na proces degradacji utlenianego anodowo stopu Ti6Al4V pokrytego powłoką biodegradowalnego polimeru. Powłoki polimerowe wykonane z poli(glikolido- ε-kaprolaktonu) – G-Cap oraz poli(glikolido ε-kaprolaktono- laktydu) – G-Cap-L naniesiono metodą zanurzeniową (dip-coating). Proces degradacji w funkcji czasu oceniano na podstawie wyników badań odporności na korozję wżerową oraz gęstości masy jonów metalowych przenikających do roztworu. Badania przeprowadzono dla próbek po 3, 6, 8, 10 i 12 tygodniach ekspozycji na środowisko korozyjne. Ponadto oceniano topografię powierzchni powłoki polimerowej. W wyniku przeprowadzonych badań potencjodynamicznych stwierdzono wyraźne obniżenie wartości oporu polaryzacyjnego i potencjału korozyjnego dla próbek z naniesionymi powłokami G-Cap i G-Cap-L przy jednoczesnym wyraźnym ograniczeniu gęstości jonów metalowych przenikających do roztworu w całym okresie badawczym. Stwierdzono również szybszą degradację powłoki typu G-Cap w porównaniu do G-Cap-L, dla której po 12 tygodniu ekspozycji stwierdzono lokalnie występujące przerwania ciągłości. Uzyskane wyniki dają podstawę do opracowywania na powierzchni implantów metalowych powłok polimerowych o przewidywalnym czasie/określonej kinetyce degradacji, poprzez dobór składu polimerów z jednoczesnym ograniczeniem możliwości przenikania jonów metalowych do otaczających tkanek.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.