Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  bezpieczeństwo obiektu budowlanego
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this paper, the results of a research on thin-plate single-lap connections are presented. Such type of connections is popular in steel roofs made of trapezoidal plates and other thin-walled elements. In case of a building safety it is necessary to ensure that materials with proper durability and ductility are used. Connections are one of the most important components in such structures, particularly when in-plane strength of a roof is taken into account. So far, in many existing regulations, only general calculations of such connections are conducted. However recently, discrete and computational methods can be used to build new, expanded mathematical design models, such as those presented here. Such models could be useful in an advanced design where a static analysis is combined with the safety assessment of the connections in a structural system. This is difficult when sheeting is utilized as a structural in-plane shear diaphragm. These require to take into consideration the important interactions of structure with covering and covering with another covering elements. The research is an effect of authors works on practical design approaches. Such methods can be effectively used for structural designs of buildings where the stressed skin diaphragm action is involved. Finally, practical input values about connections can be acquired from the presented data.
2
Content available remote Monitorowanie oddziaływań dynamicznych w sąsiedztwie budowy
PL
Ciągły w czasie, długoterminowy monitoring drgań istniejących obiektów zlokalizowanych w pobliżu prowadzonych prac budowlanych przynosi wymierne korzyści, zarówno w kontekście wzrostu bezpieczeństwa sąsiadujących obiektów, jak i w sensie ekonomicznym. Skuteczność prowadzonych pomiarów w zakresie realnej kontroli ryzyka wymaga przeanalizowania wielu czynników. Począwszy od doboru czujników oraz miejsc i sposobu ich instalacji na konstrukcji, przez zastosowanie urządzeń elektronicznych pozyskując dane z czujników, a na oprogramowaniu do analizy danych i informowania o zagrożeniach kończąc.
EN
The facilities loaded near the construction tend to vibrate and that presents a great risk. Long-term monitoring of those vibrations brings measurable benefits by increasing security of neighbouring facilities. It is also very profitable. For the real risk control measurements to be effective, there are some requirements to be met. e.g. the appropriate selection of the sensors, the place and method of their installation, the use of electronic data acquisition devices or the data analysis software.
PL
Każdy budynek czy budowla wykonywana jest wg projektu, który powinien być opracowany ze szczególna starannością przez projektanta, a efekt jego pracy był bezpieczny w użytkowaniu i dobrze służył człowiekowi. Również wykonawca i realizator projektu muszą dokładnie i starannie wykonać swoją pracę. Ogólnie wiadomo, że każdy obiekt budowlany po jego zrealizowaniu jeszcze „pracuje”. Stąd często obserwuje się rysy i spękania powstające na nowych murach. Również elementy konstrukcyjne narażone są na różnego rodzaju obciążenia i czynniki je deformujące. W artykule pokazano przykładowe możliwości, jakie daje wykorzystanie technologii skaningu laserowego 3D, do obserwacji i analizy uszkodzeń budynków oraz rejestracji ugięć ich elementów konstrukcyjnych. Jest to technologia służąca do pozyskiwania danych trójwymiarowych o mierzalnych elementach przestrzeni, który może wspomóc odnajdywanie wad i monitorowanie obiektów budowlanych. Działania takie mogą się przyczynić do szybszego wykrycia niebezpiecznych „zachowań” budowli i podjęcia działań prewencyjnych, zapobiegającym katastrofie.
EN
Each building or structure is performed by the project which should be elaborated with a special precision by the designer. Results of his work should be considered as a safe in use and well served to humanity. The contractor and the project implementer must do their work in thorough and careful manner either. It is generally known that every structure “works” even after its completion. Therefore, it is a common thing that there are seen scratches and ruptures all over a brand new wall. Also the structural elements are exposed to different kinds of loads and deforming factors. The article presents examples of the possibilities offered by the use of 3D laser scanning technology such as observation with analyzing damaged structures and registration deflections of structural elements. Because of this incredible technology people are able to obtain three dimensional data of measurable entities in the space, which can have positive effects in finding dysfunctions and monitor the buildings. Undertaking actions like these may contribute to a more rapid detection of dangerous "behavior" of structures and take preventive measures to prevent disaster.
PL
Naziemny skaning laserowy jest jedną z najszybciej rozwijających się technologii, wykorzystywaną w wielu dziedzinach nauki i życia. Metoda ta posiada ogromną ilość różnorodnych zastosowań. W niniejszym artykule przedstawiono analizę i ocenę uzyskanych danych z pomiaru metodą naziemnego skaningu laserowego (TLS) do celów badania bezpieczeństwa obiektów budowlanych. Na podstawie przeprowadzonych pomiarów oraz otrzymanych w procesie skanowania danych, pokazano błędy związane z dokładnością uzyskanych „chmur punktów”, trójwymiarowych modeli obiektów. Do zilustrowania problemów wykorzystano pomiary obiektów patio w Olsztynie i Suwałkach. Artykuł zawiera również odniesienia do dokładności pomiarów innych produktów finalnych.
EN
Terrestrial laser scanning is one of the fastest growing technology, used in many fields of science and life. This method has a lot of different applications. This article presents an analysis and evaluation of the data from the measurement method of terrestrial laser scanning (TLS) for the study of building safety. On the basis of measurements and obtained in the scanning process data, showing errors associated with the accuracy obtained "point cloud", three-dimensional object models. To illustrate the problems of measurement of objects used in Olsztyn patio and Suwalki. Article also contains references to the accuracy of the measurements of other final products.
5
Content available remote Ochrona akustyczna w budynkach
PL
W artykule podano podstawowe informacje dotyczące ochrony akustycznej w budynkach. Omówiono czynniki, od których zależy izolacyjność akustyczna, a także przedstawiono wymagania dotyczące akustyki w budynkach. Opisano przegrody biologicznie czynne jako sposób na zapewnienie odpowiedniej izolacyjności akustycznej, a także zdrowego mikroklimatu w budynku i na terenie wokół niego.
EN
The article provides basic information on acoustic insulation in buildings. It discusses the factors that determine the acoustic insulation properties, as well as presents the requirements for acoustics in buildings. Biologically active partitions are described as a way to provide adequate acoustic insulation, as well as a healthy microclimate in the building and the area around it.
6
Content available remote Diagnostyka techniczna budynku wielkopłytowego
PL
W artykule opisano specyfikę konstrukcji oraz rodzaje uszkodzeń budynków wielkopłytowych. Omówiono rodzaje metod nieniszczących, które mogą być stosowane do diagnozowania stanu konstrukcji takich obiektów. Przedstawiono ponadto wyniki badania nieinwazyjnego przeprowadzonego w budynku wielkopłytowym. Celem badania było ustalenie występowania korozji zbrojenia w elementach płytowych.
EN
The article describes the specifics of the structure and the types of damage to buildings structured with prefabricated large concrete panels. The types of non-destructive methods which can be used to diagnose the condition of such buildings were described. The results of non-invasive tests carried out in the building structured with prefabricated large concrete panels were presented. The aim of the study was to determine the presence of corrosion in reinforcement in the panel elements.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.