Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  beton piaskowy
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The present study aims to valorize the waste and in particular the waste from the Fil-fila quarry. The main reason for choosing the waste from this quarry was the need to reduce the impact on the environment (by reducing stockpiling) and the raw material cost (economic reason). This study therefore consists in recovering this type of waste (discarded powder subject to weather changes) as sand in partial replacement of dune sand in the formulation of sand concrete with percentages of 5, 10, 15 and 20 %, by studying the behavior of these concretes in the fresh state (workability, density and occluded air) and the properties in the hardened state (compressive and tensile strength by bending, absorption by immersion, shrinkage and weight loss, chemical effect of HCl and H2SO4 solutions), and subsequently comparing the results obtained with reference samples (0%) based on ordinary sand. Based on the obtained results, it can be concluded that the substitution of ordinary (dune) sand with marble waste sand provides acceptable results from the point of view of workability, strength and durability. These observations are likely to widen the field of applications of these sand concretes based on marble waste.
EN
The introduction of treated plant fibres into sand concretes leads to a reduction in density, improved ductility and thermal conductivity, and makes sand concrete an environmentally friendly and ecological material. The recovery of waste in this type of material allows the production of new ecological and sustainable materials used either in the new construction or in the rehabilitation of old buildings. In this context, a comparative study was based on the valorisation of marble and ceramic waste as sand in sand concrete made from straw fibres. To carry out this study, we introduced these wastes at substitution rates of 10% and 20%, separated and mixed, and studied the development of the properties of these concretes (density, workability, air content, compressive strength and bending tensile strength) and their behaviour with respect to durability (capillary and immersion absorption and chloride penetration). The study shows that the recovery of this waste as sand in sand concrete based on straw fibres gives satisfactory results. The chemical resistance, thermal conductivity and microstructure are under study, the results of which will be the subject of another publication.
PL
W artykule przedstawiono wyniki badań wpływu zawartości stalowego zbrojenia rozproszonego na szereg właściwości fibrokompozytów zbrojonych włóknami stalowymi wytworzonych na bazie piasków odpadowych. Autorzy podjęli także próbę wyselekcjonowania takiego fibrokompozytu, którego właściwości spełniłyby wymagania stawiane materiałom konstrukcyjnym i były lepsze niż dla betonu zwykłego. Przedstawiono szereg zalet i wad zastosowania takich materiałów. Poruszono także aspekt ekologiczny zagospodarowania hałd piasku będących wynikiem procesu hydroklasyfikacji w trakcie pozyskiwania kruszyw grubych.
EN
The article presents the results of studies on the influence of steel fibre reinforcement on a series of properties exhibited by fine aggregate composite based on waste sand. The authors also made an attempt to select such a composite which properties would meet the requirements laid out for construction materials, and exceed those of ordinary concrete. A list of advantages and disadvantages of applying such materials has been presented. The aspect of the ecological management of sand heaps which occurs as a result of the hydroclassification process when obtaining coarse aggregates has also been touched upon.
4
Content available remote Zastosowanie metod nieniszczących do oceny właściwości fibropiaskobetonu
PL
Prawidłowa kontrola jakości materiału w konstrukcji polega na ocenie jego właściwości i jednorodności metodami niepowodującymi uszkodzenia badanego elementu. Obecnie przy szerokim spektrum zastosowań fibropiaskobetonu odczuwa się brak szybkiej i bezinwazyjnej metody oceny jego właściwości. W artykule zaproponowano więc sposób oznaczania właściwości fibropiaskobetonu dwiema metodami nieniszczącymi: ultradźwiękową oraz indukcji elektromagnetycznej. Ustalono zależności, w których zmiennymi niezależnymi są natężenie indukowanego prądu oraz prędkość propagacji fali ultradźwiękowej. Zmienną zależną jest właściwość fibropiaskobetonu. Równania poddano weryfikacji praktycznej. Uzyskano zadowalającą zgodność wyników otrzymanych na drodze eksperymentalnej oraz analitycznej.
EN
The correct quality control of the material in the structure involves the assessment of its properties and uniformity usingmethods that cause no damage to the tested structural element. Currently, with a wide range of applications of steel fibre reinforced fine aggregate concrete (SFRFAC) there is lack of quick and non-invasive method for assessing its properties. This paper proposes a process for determining the properties of SFRFAC with two non-destructive methods: ultrasound method and electromagnetic induction method. The relationships were found, in which the independent variableswere the intensity of the induced current and the propagation speed of the ultrasound wave. The dependent variable was a property of tested SFRFAC. The equationswere verified in ractice. The compatibility of the results obtained experimentally and analytically was satisfactory.
PL
W niniejszym artykule przedstawiono wyniki badań ugięcia zbrojonych belek fibropiaskobetonowych (na bazie piasku odpadowego) i porównano je z wartościami wyznaczonymi zgodnie z PN-B-03264:2002 [15] i propozycją autorstwa Tana, Paramasivama i Tana [17] oraz zmodyfikowaną metodą Alsayeda.
EN
This article presents the results of investigations of the deflection of reinforced fibrous concrete beams (made with waste sand), and compares them with values determined in accordance with the PN-B-03264:2002 standard [15] and with a proposal of Tan, Paramasivam and Tan [17] and a modified method of Alsayed.
PL
Przedstawiono wyniki badań przewodności cieplnej w funkcji ponadsorpcyjnej zawartości wilgoci w piaskowych i popiołowych betonach komórkowych o różnych gęstościach. Stwierdzono wzrost przewodności cieplnej badanych betonów wraz z rosnącą zawartością wody, silniejszy w przypadku betonów piaskowych, a ogólnie - betonów cięższych. Wymiar graficzny tej zależności był zbliżony do linii prostej. Stwierdzono zauważalny wpływ początkowego rozkładu wilgoci w próbce na jej przewodność cieplną, która była największa przy równomiernym rozkładzie wilgoci, a najmniejsza przy usytuowaniu całej wilgoci po zimnej stronie próbki. Przepływ wilgoci w próbce w czasie badania był ilościowo proporcjonalny do jej nierównomiernego rozkładu, największy przy początkowym usytuowaniu całej wilgoci po ciepłej stronie próbki.
EN
The paper describes test results of thermal conductivity of sand and ash cellular concretes of diverse densities in function of over sorption moisture content. It has been found that dependence of thermal conductivity on over sorption moisture content is, in graphic size, close to straight line. This dependence is stronger for sand cellular concretes and, generally, for heavier concretes. Initial moisture distribution in test sample affected its thermal conductivity, so that the maximum was observed for the steady moisture distribution and minimum for moisture located near cold side of sample. Moisture flow in sample during the test was proportional to unequal moisture distribution in it, maximum for moisture location near warm side of sample.
PL
Przedstawiono wynki badań sorpcji i przewodności cieplnej w funcji zawartości wilgoci betonów komórkowych piaskowych i popiołowych o różnych gęstościach. Stwierdzono, że wilgotność sorpcyjna betonów komórkowych wyraźnie rośnie i zbliża się do 15% dopiero przy wilgotności względnej powietrza dochodzącej do 100%. Wzrost przewodności cieplnej betonów komórkowych w wyniku sorpcji w powietrzu o wilgotności względnej do 80 % jest nieduży i nie przekracza 15%. Znaczny wzrost przewodności cieplnej, w przybliżeniu do 45%, następuje wskutek kondensacji kapilarnej przy wilgotności względnej powietrza powyżej 80%.
EN
The paper describes test results of sorption and thermal conductivity of sand and ash cellular concretes of different densities in function of moisture content. It has been found that sorption moisture content of cellular concretes distinctly increases and approaches 15% with RH of air reaching 100%. The rise of thermal conductivity of cellular concretes as result of sorption to 80% air RH is not large and does not exceed 15%. Significant rise of thermal conductivity, approximately to 45%, takes place due to capillary condensation with RH over 80%.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.