Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  beton jamisty
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Pervious concrete is a unique and effective material used to tackle important environmental problems, to maintain green, sustainable growth, and to reduce storm water runoff and pollutants. Clogging of pervious concrete is an important potential issue in serviceability, considered one of the primary limitations of pervious concrete systems. The sediment deposition pattern of pervious concrete was determined using three clogging materials: clay, sand, and clayey silty sand. The clogged specimens were cleaned by pressure washing, vacuuming, and a combined method. In total, ten clogging and cleaning cycles were carried out on each sample to evaluate the draining capacity of the pervious concrete. The clogging test was assessed by measuring the infiltration rate during clogging and after cleaning, for each cycle. The experiment results showed that a reduction in permeability due to different types of sedimentation material as well as recovery in permeability was achieved after applying various cleaning methods.
PL
Urbanizacja stwarza liczne problemy, takie jak erozja, gwałtowne powodzie, zanieczyszczenie rzek oraz efekt wyspy ciepła. Beton jamisty jest przyjaznym dla środowiska materiałem nawierzchniowym, który częściowo ogranicza wyżej wspomniane problemy, a także służy zachowaniu środowiska naturalnego, zmniejszając spływ wody burzowej, zanieczyszczenia oraz miejskie ciepło. Beton jamisty jest podobny do zwykłego betonu, z wyjątkiem dodatku drobnego kruszywa, które tworzy połączone ze sobą puste przestrzenie umożliwiające przepływ wody przez betonową matrycę. Pustki od 15% do 35% całkowitej objętości betonu jamistego są utrzymywane za pomocą gruboziarnistego kruszywa o ciągłej krzywej przesiewu i gęstego cementu, który zapobiega oddzielaniu się pasty od kruszywa. Wydajność hydrauliczna betonu jamistego dla odprowadzenia wody burzowej zależy od szybkości odkładania się osadu w odniesieniu do okresu czasu. Kolmatacja betonu jamistego stanowi istotny potencjalny problem w zakresie użytkowalności, który jest uważany za jedno z podstawowych ograniczeń w systemach betonu jamistego. Kolmatacja odnosi się do zmniejszenia przepuszczalności porowatego ośrodka ze względu na proces fizyczny, chemiczny i biologiczny. Głównymi źródłami kolmatacji są zawieszone cząstki z powierzchniowych wód spływających, a także organiczne i nieorganiczne cząstki pochodzące z ruchu drogowego i miejscowej roślinności lub pyłu wydmuchiwanego na jezdni. Niniejsze badanie koncentruje się na wydajności hydraulicznej systemu betonu jamistego poprzez wywoływanie kolmatacji przy użyciu różnych materiałów sedymentacyjnych i ocenie zdolności infiltracji betonu jamistego. Prace eksperymentalne przeprowadzono, aby zrozumieć przydatność metod renowacyjnych w przywracaniu wydajności hydraulicznej betonu jamistego. Celem tego badania jest ocena efektu kolmatacji betonu jamistego w oparciu o trzy różne materiały sedymentacyjne, trzy różne stopnie uziarnienia kruszywa i trzy metody renowacji. Służy to określeniu zmniejszenia przepuszczalności po kolmatacji i resztkowej przepuszczalności po oczyszczeniu próbek betonu jamistego.
2
Content available remote Mechanical properties of no-fines concrete
EN
The paper presents a laboratory study to determine the relationship between compressive strength of no-fines concrete (NFC) and its tensile strength measured both by double-punch test and modulus of rupture test methods. The compressive strength was carried on 100 x 100 x 100 mm cubes. The specimens for tensile strength tests were 150 x 150 mm cylinders, and 100 x 100 x 500 mm beams. Crushed limestone was used as coarse aggregate with max size of 19 mm. Sixteen concrete mixes were prepared with water-to-cement ratios: 0.40; 0.42; 0.44; and 0.46 cement-to-aggregate ratios (C/A) 1 : 5, 1 : 7, 1 : 9, and 1 : 11. The total of 48 cubes, 48 cylinders, and 48 beams were prepared. Compressive and tensile strength tests were carried on the concrete specimens according to relevant standards ASTM-C39/C39M. 2016 and ASTM-C78/C78M. 2015 and the average of three results was recorded each time. It was found that tensile strength measured by modulus of rupture test gave higher results than that measured by double-punch test. The tensile strength from the double-punch test was about 20% of the compressive strength and from the modulus of rupture was about 30% of the compressive strength according to test results obtained in this study.
PL
W artykule przedstawiono badania laboratoryjne mające na celu określenie zależności pomiędzy wytrzymałością betonu jamistego na ściskanie i rozciąganie, stosując próbę podwójnego przebicia i trzypunktowego zginania. Wytrzymałość na ściskanie badano na kostkach 100 x 100 x 100 mm. Wytrzymałość na rozciąganie określono na próbkach walcowych 150 x 150 mm oraz belkowych 100 x 100 x 500 mm. Jako kruszywo grube zastosowano kamień wapienny o maksymalnym uziarnieniu 19 mm. Przygotowano 16 mieszanek betonowych o wskaźniku w/c: 0,40; 0,42; 0,44 i 0,46 oraz proporcji cementu i kruszywa (C/A) 1 : 5, 1 : 7, 1 : 9 i 1 : 11. Łącznie wykonano 48 kostek, 48 próbek walcowych i 48 belkowych. Próby na rozciąganie i ściskanie wykonano zgodnie z normami ASTM-C39/C39M. 2016 i ASTM-C78/C78M. 2015, za każdym razem wyznaczając średnią z trzech pomiarów. Wytrzymałość betonu na rozciąganie otrzymana w wyniku próby zginania była większa niż w przypadku próby podwójnego przebicia. Wstosunku do wytrzymałości na ściskanie wytrzymałość betonu na rozciąganie w próbie podwójnego przebicia stanowiła 20%, a wytrzymałość na zginanie w próbie trzypunktowego zginania – 30%.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.