The paper describes an example of an experiment on sliding friction of metallic materials in which vibration measurement methods were used to identify friction induced vibrations occurring in sliding. The determination of the parameters of the motion of the critical components in the sliding system in different modes of operation allowed using the vibration signal as a source of information pertaining to the observed process. The tests performed with a metallic material were inspired by the earlier research performed with machine ceramics in which the result of vibration analysis allowed the determination of the correctness of measurement with regard to the conditions of contact and the analyses of the nature of the observed effect of vibration on the inflicted friction. The motion analysis data was used as a basis for a screening method eliminating corrupted measurements from the data set used for global evaluation of the friction characteristics. It was confirmed that, in a steel-on-steel sliding system, similar friction and vibration regimes occur as in ceramics-on-ceramics, but the effects of certain vibration modes are opposite in the two systems, despite the same load/velocity conditions.
PL
W artykule opisano przykład doświadczenia z tarciem ślizgowym w jednoimiennym skojarzeniu materiałów metalicznych. W doświadczeniu tym wykorzystano metody pomiaru drgań do identyfikacji samowzbudnych drgań ciernych występujących podczas ślizgania. Identyfikacja parametrów ruchu kluczowych elementów układu badawczego w różnych stanach pracy pozwoliła na wykorzystanie sygnału drganiowego jako źródła istotnych informacji o obserwowanym procesie. Badania wykonane z użyciem materiałów metalowych zostały zainspirowane wcześniejszymi pracami o podobnym charakterze przeprowadzonymi na próbkach wykonanych z ceramiki maszynowej. Po przeprowadzeniu analizy drgań możliwa jest ocena prawidłowości pomiaru ze względu na warunki styku oraz analiza oddziaływania drgań na wywoływane tarcie. Analiza ruchu stała się podstawą do oceny przesiewowej wyników pomiarów ze względu na prawidłowość warunków pomiaru i eliminację danych zarejestrowanych z zakłóceniami ze zbioru użytecznego. Po korekcie zbiór danych może zostać wykorzystany do aproksymacji funkcyjnej charakterystyki tarcia ślizgowego w zakresie wymuszeń stosowanych podczas opisywanych badań. Przedstawiono potencjalne konsekwencje wprowadzenia opisanej metody dla końcowych wyników doświadczeń z tarciem ślizgowym.
2
Content available remote Alternative Test Methods for Assessing Mechanical Properties of Disposable Diapers
EN
It is essential to examine the mechanical properties of disposable diapers that contact the skin and affect the dermatitis of babies and infants. Until now, the KES-F system has been used to determine the mechanical properties of disposable diapers. In this study, alternative methods are used to measure the mechanical properties of disposable diapers. We examined, in both dry and wet conditions, the coefficient of friction (MIU), the mean deviation of coefficient of friction (MMD), and the surface roughness (SMD) obtained from the friction tests, the compressional energy (WC), the compressional resilience (RC), and the linearity of compression curve (LC) obtained from the compression tests, the coefficient of heat transfer (K), and the maximum value of heat flux (q) obtained from the heat transfer tests, and the thickness (T) and the weight (W) obtained from the construction tests. The KES-F system has also been used for compression and friction tests for comparative reason. The contents of leakage performance were tested with wetback, absorption area, absorption capacity and retention capacity tests. After wetting, it appeared that while the MIU, MMD, SMD, and LC values increase, the RC values decrease in both the KES-F system and alternative methods. The results obtained from the KES-F system and the alternative methods demonstrate different characteristics, due to the differences in measurement techniques.
EN
The subject of the analysis is the test stand for friction and wear investigation and the method of friction coefficient determination with its application. In the paper is shown the fact that geometric features of the friction pair and the measurement method of the friction coefficient could affect significantly the values of the friction coefficient determined in tests. Analytical solutions obtained for analysed designs of the test stand allow for the estimation of errors that are independent on applied measurement sensors but could appear in the determination of the real value of the friction coefficient.
PL
Przedmiotem analizy było stanowisko do badania tarcia i zużycia oraz sposób wyznaczania z jego pomocą wartości współczynnika tarcia. W pracy zwrócono uwagę na fakt, że cechy geometryczne węzła tarcia oraz sposób pomiaru oporu tarcia mogą mieć istotny wpływ na wyznaczane w badaniach wartości współczynnika tarcia. Dla zanalizowanych rozwiązań stanowiska badawczego uzyskano zależności pozwalające szacować błędy, które - niezależnie od stosowanych czujników pomiarowych - można popełnić w ocenie rzeczywistej wartości współczynnika tarcia.
PL
Zaprezentowano wyniki badań będących bezpośrednią kontynuacją wcześniejszych prac z zakresu badania drgań wywołanych tarciem. Badano konforemne płaskie skojarzenie pierścieniowe, z monolitycznego AI2O3 smarowanego olejem parafinowym. Badania wykonano na Tribometrze PT-3 wyposażonym w komputerowy system sterująco - pomiarowy umożliwiający wielokanałową, szerokopasmową rejestrację przyspieszeń, sił i przemieszczeń. Układ badawczy Tribometru zmodyfikowano, umożliwiając prowadzenie badań przy zmiennej bezwładności i sztywności podparcia. Zarejestrowano drgania cierne o dwóch stopniach swobody, w szerokim zakresie obciążeń i prędkości ślizgania. Dokonano analizy wpływu warunków badań z uwzględnieniem cech dynamicznych maszyny badawczej na obserwowane tarcie ślizgowe.
EN
Results from research on friction induced vibrations in a flat ceramic contact are presented. Flat annular - shaped Al2O3 ceramic specimens lubricated with paraffin oil were used. The research was carried out on PT-3/99 Tribometer equipped with a wide - band vibration data acquisition system with signal feeds for accelerations, forces and translations. The test rig was equipped with a modified test set - up with variable inertia and stiffness characteristics. Friction induced vibration with two degrees of freedom was observed over a wide range of sliding velocity and load. The influence of inertia and stiffness of the test set - up on the course of sliding friction and friction induced vibration was analysed.
PL
W pracy przedstawiono wyniki badań emisji akustycznej (EA) generowanej w procesie tribologicznym węzła tarciowego wybranych maszym służących do badania tarcia. Stwierdzono, że sygnał EA niesie bezpośrednią informację o biegu procesu tribologicznego i stanie pary trącej.
EN
The paper presents investigation results of acoustic emission (EA) generated in the tribological process of friction couple of chosen machines used for tribological investigations. It was stated, then EA signal carries direct information on the course of the tribological process and on the state of the friction couple.