Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 14

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  błędy pomiaru
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
For highly reliable and long-life products, accelerated degradation test (ADT) is often an effective and attractive way to assess the reliability. To analyze the accelerated degradation data, it has been well recognized that it is necessary to incorporate three sources of variability including the temporal variability, the unit-to-unit variability and measurement errors into the ADT model. The temporal variability can be properly described by the Wiener process. However, the randomness of the initial degradation level, which is an important part of the unit-to-unit variability, has been often neglected. In addition, regarding the measurement errors, current ADT models often assumed them to follow a mutually independent normal distribution and ignored the autocorrelation that may probably exist in them. These problems lead to a poor accuracy for reliability evaluation in some situation. Thus, a random-effect Wiener process-based ADT model considering one-order autoregressive (AR(1)) errors is proposed. Then closed-form expressions for the failure time distribution (FTD) is derived based on the concept of first hitting time (FHT). A statistical inference method is adopted to estimate unknown parameters. Finally, a comprehensive simulation study and a practical application are given to demonstrate the rationality and effectiveness of the proposed model.
PL
W przypadku wysoce niezawodnych produktów o długim cyklu życia, przyspieszone badanie degradacji (ADT) często stanowi skuteczny i atrakcyjny sposób oceny niezawodności. Jak wiadomo, analiza danych z przyspieszonej degradacji wymaga włączenia do modelu ADT trzech źródeł zmienności, w tym zmienności czasowej, zmienności między jednostkami i błędów pomiarowych. Zmienność czasową można odpowiednio opisać za pomocą procesu Wienera. Jednak losowość początkowego poziomu degradacji, który stanowi ważną część zmienności między jednostkami, jest często w badaniach pomijana. Ponadto, w odniesieniu do błędów pomiaru, obecne modele ADT często zakładają, że mają one wzajemnie niezależne rozkłady normalne, ignorując możliwą autokorelację. Problemy te prowadzą w niektórych sytuacjach do niskiej trafności oceny niezawodności. W związku z powyższym, zaproponowano model ADT oparty na procesie Wienera z efektem losowym, w którym uwzględniono błędy autoregresyjne pierwszego rzędu (AR (1)). Następnie, w oparciu o pojęcie pierwszego czasu przejścia, wyprowadzono wyrażenia w postaci zamkniętej dla rozkładu czasu uszkodzenia (FTD). Do oszacowania nieznanych parametrów przyjęto metodę wnioskowania statystycznego. Na koniec przedstawiono kompleksowe studium symulacyjne i wskazano praktyczne zastosowanie modelu w celu wykazania jego racjonalności i skuteczności.
EN
In this paper the influence of oil pockets location on extraction of surface topography features was taken into account. Plateau-honed cylinder liners with additionally added dimples were taken in consideration. The effect of dimples location on the application of various procedures (cylinder fitting procedure, polynomial approximation) for areal form removal was taken into account. It was noticed that application of 3rd (or greater) degree of the polynomials can caused false estimation of reference plane; extraction of surface topography features by polynomial approximation cannot provide good results when the distance between dimples is too small. For two-process surfaces (plateau-honed cylindrical elements containing wide and deep valleys) the digital filtering was proposed. Application of robust techniques (robust Gaussian regression filter) allowed for areal form removal improvement. However, some of the wide dimples were distorted when the dimple-to-edge distance was too small (smaller than filter bandwidth value).
3
Content available remote Jak długi jest stół? O pomiarach słów kilka
PL
Podstawowym i najczęściej stosowanym miernikiem w fotometrii jest luksomierz. Aby mierzone natężenie oświetlenia odpowiadało wartości odniesienia, miernik ten musi spełniać szereg wymagań, do których zalicza się m.in. korekcję widmową oraz przestrzenną głowicy foto-metrycznej luksomierza. W ostatnich latach na rynku można spotkać coraz więcej fotometrów, które z uwagi na niską cenę cieszą się dużym zainteresowaniem. Bardzo często ich koszt jednostkowy jest niższy od ceny wzorcowania. W artykule, na podstawie przeprowadzonych pomiarów laboratoryjnych, przeanalizowano wybrane właściwości metrologiczne powszechnie używanych typów luksomierzy podczas weryfikacji parametrów oświetlenia we wnętrzach. Pomiarom poddano zarówno mierniki o wysokiej, jak i o niższej dokładności. Wobec faktu, że do oświetlania wnętrz stosowane są źródła światła o różnych rozkładach widmowych emitowanego promieniowania, zarejestrowano wskazania poszczególnych luksomierzy przy oświetleniu ich powierzchni światłoczułych lampami wyładowczymi oraz źródłami LED. Uzyskane wartości odniesiono do pomiarów otrzymanych przy użyciu lampy żarowej o temperaturze barwowej Tc = 2856 K – źródle, którego promieniowanie wykorzystywane jest przy wzorcowaniu fotometrów. Na podstawie przeprowadzonych badań wyznaczono błędy względne oraz błędy kosinusowe luksomierzy, a także współczynniki (wskaźniki) korekcji barwy. Pomiary uzupełniono rejestracją rozkładów widmowych źródeł światła wykorzystanych podczas pomiarów eksperymentalnych.
EN
An iluminance meter is the basic and most frequently used measuring instrument in photometry. This instrument must meet a number of requirements e.g. a spectral and space correction of the photoelement in order to have the illuminance corresponding to the actual value. In the recent years, more and more photometers can be found on the market, which have generated a lot of attention because of their low price. Their individual cost is very often lower than the calibration price. On the grounds of the performed laboratory measurements, the chosen metrological attributes of commonly used luxmeters during the indoor verification of lighting parameters were analysed in the article. Instruments of high as well as low accuracy were tested. During the indoor lighting the light sources of different spectral concentration are used. Concerning this fact the individual luxmeters read-outs with light-sensitive surfaces lighted by the discharge lamp as well as LED sources were registered. Obtained results were compared with the values received during measurements carried out with the use of an electric lamp of the colour temperature Tc = 2856 K, i.e. a source, which radiation is used during the calibration of photometers. The relative and cosine errors as well as the colour correction coefficients (factors) were set down based on the carried out measurements. They were complemented with the registration of the spectral concentration locus of the light sources used during the experimental measurements.
PL
W pracy omówiono wpływ polaryzacji światła na wyniki pomiarów spektroradiometrycznych. Przeprowadzono pomiary testowe, które wykazały zmienność wyników pomiaru w funkcji kierunku i stopnia polaryzacji (całkowitej lub częściowej). Fakt częściowej polaryzacji światła odbitego od powierzchni np. wody (na drodze lub na jeziorach itp.) występuje w praktyce częściej niż mogłoby się wydawać, a w zastosowaniach technicznych może być realizowany celowo. Może to mieć znaczenie np. przy procesach identyfikacji barw w zautomatyzowanej aparaturze pomiarowej. W niezbędnych przypadkach, zwłaszcza w przypadku wymagań wysokich dokładności pomiarowych (np. w zastosowaniach badawczych), może to wymagać indywidualnej kalibracji urządzenia pomiarowego.
EN
In this work Influence of light polarization on results of spectroradiometric measurements of light parameters is discussed. Test measurements are carried out, which have exerted variability of result of measurement in function of direction and degree of polarization (full or partial). Fact of partial polarization of light reflected from flat surface (on roads or lakes etc) often takes a stand in practice - in different degree. It can be realized in technical employment expediently. It can be meaning full e.g. at process of color identification in automated measuring equipment. In essential cases, especially in high claimed measuring accuracy requirements (e.g. In investigative employment) the individual i calibration of measuring device can be necessary. The influence of light polarization on the method and quality of its spectrofotometric parameters.
PL
Wielkości fizyczne i parametry chemiczne paliw i energii mogą być mierzone i wyznaczane w sposób mniej lub bardziej dokładny, ponieważ każdemu pomiarowi towarzyszy błąd pomiaru. W przypadku wykorzystywania wyników pomiarów do rozliczeń handlowych, błędy pomiaru powodują poważne skutki finansowe.
PL
Artykuł przedstawia programową metodę zwiększania dokładności odczytu sygnałów pomiarowych przetworników pomiarowych. Jej przeznaczeniem jest zwiększanie dokładności odczytu danych pomiarowych w zastosowaniach wymagających dokładnych i szybkich pomiarów. Przedstawiono ideę pomiaru, przetwarzania i korekcji wielkości mierzonej. Zaprezentowano sposób wyprowadzenia równań korekcji dla typowego przetwornika pomiarowego. Pokazano sposób zastosowania korekcji dla układu pomiarowego. Porównano wyniki pomiarów wykonanych w układzie do pomiarów parametrów drgań z korekcją i bez korekcji.
EN
The article presents software method of increase of measurement signals accuracy of reading from measuring transducers. Destination of this method is increasing the precision of data read in application that need precise and fast measurements. Idea of measurement, transformation and correction of measuring quantity have been shown. Derive method of equation of correction for typical measuring transducer and way of use of correction for measuring system have been shown. Obtained measuring results with and without correction made in vibration measuring system have been compared.
PL
W artykule przedstawiono wyniki analizy wpływu nieprostopadłości promieni zarysów okrągłości przedmiotu mierzonego do stycznych tworzących kąt rozwarcia pryzm ustalających ten przedmiot na wartość względnego błędu mierzonej odchyłki okrągłości. Wyniki tej analizy przedstawione w formie wykresów pozwalają wnioskować, że wartość rozpatrywanego błędu uzależniona jest w dużej mierze od nieregularności zarysu przekroju mierzonego i zarysów powierzchni przedmiotu stykających się z powierzchniami pryzm ustalających.
EN
The paper presents analysis results of the effect of non-perpendicularity of the measured object roundness contour radiuses to the tangents making up the Vee angle of the fixing V-blocks on the value of the relative error of the measured roundness deviation. Basing on the analysis results shown in the form of diagrams one can draw a conclusion that the value of the examined error largely depends on the measured cross-section contour irregularity as well as on the contours of the object surface contacting the V-block surfaces.
EN
The linear regression eąuations describing relation of soil heat flux density values in daily course derived from the indirect (combined) method and flux-plates were used for correction of heat flux plate data on a given day. In the case the gaps occur in comparative materials (i.e. from indirect method), the correction problem of heat flux plate data in the multiday series of measures may be solved in the following way: applying the equation from one day (recognised as representative) for other days; by determination of the correction equation on the basis of the data comprised of a few days together, or a set of data from a great number of days during the measurement season. All these conceptions of performance correction of heat flux plate data were examined regarding their usefulness (exactly, the error magnitude obtained using these equations), but only in respect to days and periods without precipitation. It was stated that applying one equation for correction of heat flux plate data in the course of a long (e.g. several months) period is unreasonable (improper). However, the correction using the equation from one day for the other days, as well as the equation obtained from a few days give correct results on condition that the days taken into considcration are not too distant and precipitation is not recorded at this time (the soil physical properties did not undergo any significant changes).
EN
The results of soil heat flux density measurement using flux plates are as a rule burdened with substantial errors. Therefore, the verification of heat flux plate data is necessary it may be performed by comparing these data to obtained by the other method, recognised a control. In this paper, there is examined the relation between the values of soil heat flux density from plates burried at the depth of 1 cm and these obtained by combined method (i.e. heat storage changes within soil layer 1-20 cm and flux at depth 20 cm determined by gradient method). The ground for the analyses was constituted by the results of measurements carried out on the cultivated field without plants during the selected three days that were characterized by different weather and soil moisture conditions. The regression equations describing relation of soil beat flux density values (mean for one hour) derived from indirect method and flux plates in daily course were determined separately for each day. It was stated that values of the numerical coefficients in these equations differed significantly with regard to different soil moisture (as a consequence, a diverse relation of soil thermal conductivity to heat flux plate one) as well as different contact between soil material and plate. Therefore, if such equations are to be used for the correction of the flux-plates data, they should be applied, as a rule, only this day they were determined for.
PL
W artykule przedstawiono wyniki badań eksperymentalnych laboratoryjnego modelu miernika impedancji pętli zwarciowej. Miernik ten umożliwia pomiar impedancji pętli zwarciowej w sieci z pracującymi obciążeniami roboczymi z eliminacją wpływu tych obciążeń na wynik pomiaru. Badania przeprowadzono dla parametrów badanego obwodu i miernika, jakie można spotkać w praktyce. Wyniki badań przedstawione w formie wykresów wykazuj ą, że miernik ten charakteryzuje się wystarczającą dokładnością pomiaru w sieci z pracującymi obciążeniami roboczymi
EN
This paper describes an experimental study results of the new meter for short-circuit loop impedance measurement. This method enables us to measure short-circuit loop impedance in network with operating loads. In this method the influence of operating loads on measurement result is eliminated. The laboratory test was carried out under laboratory condition with the parameters of the tested circuit and meter encountered in practice. The tesing results are presented in form of graphs which shows that the measurement accuracy of the new meter is sufficient in network with operating loads.
13
Content available remote Dokładność cyfrowego przyrządu ilorazowego
PL
Przedstawiono problemy wyznaczania klasy dokładności przyrządu ilorazowego,w którym wykonuje sie pomiary dwóch wielkości, a uzyskane wyniki poddaje sięoperacji dzielenia. Przedstawiono specyficzne zachowanie się błędu podstawo-wego w przyrządach tego typu oraz zaproponowano nowe podejście do problemuwyznaczania klasy takich mierników.
first rewind previous Strona / 1 next fast forward last