Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  aspirin
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A simple, sensitive, specific, and cost effective method for simultaneous determination of Aspirin and Rosuvastatin calcium was developed and validated in single dosage formulation. The sample solution of ASP and RSTC was prepared using methanol as a solvent. Separation of ASP and RSTC was achieved with a mobile phase consisting of 20 mM KH2PO4 : Methanol (30:70 v/v) at a flow rate of 1.0 ml/min. Separations were performed on Merck hibar 250-4.6 RP18 (5 μm) column (150 mm X 3.0 mm), using a Shimadzu Prominence HPLC system equipped with a Shimadzu SPD-20A detector, Rhenodyne 7725i injector with 20 μL loop, LC-20 AD pump, CBM-20 Alite controller and LC Solution software. Retention times of ASP and RSTC were 3.747 and 5.969 minutes respectively. Absolute recovery of ASP and RSTC was 100.3 and 100.03 % respectively. The lower limit of quantification (LLOQ) of ASP and RSTC was 0.3097 and 0.1063 ppm and lower limit of detection (LLOD) of ASP and RSTC was 0.01535 and 0.01358 ppm respectively. Linearity was established for the range of concentrations 15.00-90.0 μg/ml and 2.0-12.0 μg/ml for ASP and RSTC respectively with the coefficient of determination (R2) of 0.994 and 0.999 for both the compounds. The inter- and intra-day precision in the measurement of ASP quality control (QC) sample 75 μg/ml, were in the range 0.1-0.2 % relative standard deviation (R.S.D.) and 0.2-0.3 % R.S.D., respectively. The inter- and intra-day precision in the measurement of RST quality control (QC) sample 10 μg/ml, were in the range 0.1-0.2 % R.S.D., and 0.0-0.3 % R.S.D., respectively. The developed method would be applicable for routine quality control of ASP And RSTC in bulk as well as in pharmaceutical formulations.
EN
An isocratic reversed-phase liquid chromatograpic assay method was developed for the quantitative determination of atorvastatin and aspirin (ASP) in combined dosage form. A Phenomenex Gemini C-18, 5-μm column with mobile phase containing 0.02 M potassium dihydrogen phosphate-acetonitrile-methanol (30:30:40, v/v/v) adjusted to pH 3 using o-phosphoric acid was used. The flow rate was 1.0 mL min -1 and effluents were monitored at 240 nm. The retention times (RTs) of atorvastatin calcium (ATV) and ASP were 10.5 and 3.8 min, respectively. ATV and ASP stock solutions were subjected to acid and alkali hydrolysis, chemical oxidation, and dry heat degradation. The degraded product peaks were well resolved from the pure drug peak with significant difference in their RT values. Stressed samples were assayed using developed LC method. The proposed method was validated with respect to linearity, accuracy, precision, and robustness. The method was successfully applied to the estimation of ATV and ASP in combined capsule dosage forms.
EN
A simple, precise, and accurate HPTLC method has been established for simultaneous quantification of aspirin, atorvastatin calcium and clopidogrel bisulphate in the bulk drug and in a capsule dosage form. Chromatographic separation of the drugs was performed on aluminium foil plates precoated with silica gel 60 F 254 , with toluene-methanol-formic acid 6.5:3.5:0.1 ( v / v ) as mobile phase. Densitometric evaluation of the separated zones was performed at 254 nm. The three drugs were satisfactorily resolved with R F ± SD values 0.26 ± 0.01, 0.47 ± 0.01, and 0.78 ± 0.01 for aspirin, atorvastatin calcium, and clopidogrel bisulphate, respectively. The method was validated for linearity, specificity, accuracy, precision, and robustness, in accordance with ICH guidelines. Results from recovery studies indicated acceptable recovery of the drugs from the capsule dosage form. The intra-day and inter-day relative standard deviations were in the ranges 0.17–0.73% and 0.46–1.03% for aspirin, 0.36–0.87% and 0.44–0.62% for atorvastatin calcium, and 0.25–0.69% and 0.35–0.94% for clopidogrel bisulphate. The method proved to be a rapid and cost-effective quality-control tool for routine simultaneous analysis of aspirin, atorvastatin calcium, and clopidogrel bisulphate in the bulk drug and in a capsule formulation.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.