Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  area mass
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Physical and Mathematical Modelling of the Phenomenon of Fur Knitting Compression
EN
While analysing the dependencies between the compression-ability parameter S (the squeezing parameter) and parameters describing fur knittings, i.e. the initial free thickness g0 of its pile and the area mass G of the knitting, we have not stated the existence of simple functional relations. This was why we made an attempt to determine the theoretical dependencies between the mechanical and the structural parameters of the fur knittings for the physical model of the fibres’ pile which we elaborated and accepted. For the function elaborated, S = S1 (G2 /g04)-a, we obtained a correlation coefficient R of 0.80 by approximating the experimental results.
PL
Analizując zależności między parametrem zgniatalności Z a parametrami takimi jak: grubość początkowa go oraz masą powierzchniową G dzianiny futerkowej, nie stwierdzono prostych związków funkcyjnych. Wobec tego podjęto próbę określenia zależności teoretycznych między parametrami mechanicznymi i strukturalnymi dzianin futerkowych dla przyjętego modelu fizycznego włókna okrywy. Dla uzyskanej funkcji teoretycznej typu: Z = Z1 (G2/go4)-a otrzymano, przy aproksymacji wyników eksperymentalnych, współczynnik korelacji R= 0,80.
EN
This experimental study aims to investigate the performance of towels. In order to do this, we obtained the relationships between the towel’s performance and selected characteristic properties such as pile highness, aerial density, type of softeners, and dyeing process. For this purpose, the selected towel samples were tested in accordance with the determination of degree of hydrophility, softness, and dimensional change after washing; then the results obtained were analysed. In this first part of our investigation, the effects of pile highness and aerial density on the bending resistance or the softness of towels have been discussed.
PL
Eksperymentalne badania poświęcono ocenie cech użytkowych i jakości ręczników. W tym celu określono zależności pomiędzy właściwościami ręczników, określającymi ich walory użytkowe, takie jak stopień zwilżalności, miękkość i zmiany wymiarów po praniu, a wybranymi parametrami technologicznymi procesu produkcyjnego: wysokością okrywy, masą powierzchniową, typem zastosowanego zmiękczacza i parametrami procesu barwienia. Wyselekcjonowane próbki były testowane a wyniki analizowano. Szczegółowo przedstawiono wpływ wysokości okrywy i masy powierzchniowej na oporność zginania i miękkość ręczników.
3
Content available remote Thermal Analysis and Performance Properties of Thermal Protective Clothing
EN
In this study, a thermal protective performance (TPP) test was applied for thermal analysis. The thermal analysis by the TPP test was carried out on the single layer-fabrics and their assemblies in two- and three-layerconstructions. The thermal protective performance ratings of these constructions and each single outer layer fabrics were determined. Thickness and area mass seem to influence the TPP ratings of single-layer fabrics. Four types of outer layer fabrics and one type of third-layer fabric were also tested in the Du Pont Engineering Fibres Laboratory. The results obtained in our laboratory were compared with Du Pont’s test results. Also, each fabric was washed 1, 3, 5, and 10 times. TPP ratings, air permeability, area masses and tear strengths of fabrics were measured before and after certain washing cycles. Dimensional changes at the end of washing were also determined. The highest TPP ratings were obtained from the three-layer (outer layer + thermal barrier + inner layer) structures. According to the results, fabrics shrink, air permeability values and tear strengths were decreased, and the area mass of test samples increased with the increase in the number of washing cycles. Washings cause a decrease in TPP ratings of single-layer fabrics and an increase in TPP ratings of multi-layer constructions.
PL
W przedstawionych badaniach wykonano test "termicznych właściwości zabezpieczających " (TWZ) w celu przeprowadzenia analizy termicznej badanych materiałów. Jako przedmiot badań wybrano pojedyncze płaskie wyroby włókiennicze, jak również ich dwu- i trzywarstwowe zestawy. Zaobserwowano, że grubość pojedynczych próbek oraz ich masa powierzchniowa wpływają na pomierzone wartości TWZ. Cztery typy materiałów odzieżowych, przeznaczonych na okrycia wierzchnie oraz jeden kompozyt trójwarstwowy przebadano również w Du Pont Engineering Fibres Laboratory. Wyniki badań z obydwu laboratoriów (Du Pont 'a i uniwersyteckiego) porównano między sobą uzyskując zadowalającą zgodność wyników. Każdy z materiałów był następnie prany lx, ix, 5x i 10x krotnie. Mierzono TWZ, przepuszczalność powietrza, masę powierzchniową i wytrzymałość na zrywanie przed i po każdym cyklu prania. Stwierdzono również zmiany wymiarów badanych materiałów po praniu. Najwyższe TWZ stwierdzono dla kompozytu trójwarstwowego o układzie: warstwa zewnętrzna + bariera termiczna + warstwa wewnętrzna. Wraz ze wzrostem ilości cyklów prania, wzrastał skurcz i masa powierzchniowa, podczas gdy przepuszczalność powietrza i wytrzymałość zmniejszały się. Pranie powodowało spadek wartości TWZ dla tekstyliów pojedynczych i wzrost dla kompozytów wielowarstwowych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.