Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  aparat ortodontyczny
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Fretting in orthodontics and its test methods
EN
Purpose: A review of the literature regarding the occurrence of fretting wear in orthodontics and its test methods have been presented. Design/methodology/approach: The influence of micro-movements occurring in the oral cavity on the occurrence of fretting wear in a fixed orthodontic appliance is discussed. The fretting test methods were analysed, taking into account tine shape of the samples and the amplitude of the movements, calculated according to the Hertz contact problem. Fretting-corrosion tests on tines wear of materials are included. Findings: Fretting occurs between the bracket and the orthodontic archwire in a fixed appliance. The test of the amount of wear material mainly uses samples created for the needs of the device. The test of ready-made components of a fixed appliance usually relate to the value of the coefficient of friction. The use of coatings increases the coefficient with the simultaneous reduction of the amount of wear material. Fretting-corrosion occurring in the oral environment has a negative impact on the wear of materials. The value of the total area of abraded material after fretting is unknown. Research limitations/implications: Particles of fretting wear
2
EN
Commercial orthodontic appliance components (wires, bands and brackets) were exposed to Ringer’s solution. EDS analyses showed that the materials were made of chromium-nickel steel. SEM examinations revealed only slight changes in the metallic surface of the orthodontic brace components after they had been kept in the Ringer solution (for 77 days). No potentiodynamic tests can be carried out on the orthodontic bands and brackets because of their complicated shape and small size. The electrochemical tests performed only for orthodontic wires. Potentiodynamic tests showed that the maximum rate of corrosion of the orthodontic wire made of chromium-nickel steel in the artificial body fluid amounted to 2.1·10-6 A/cm2. The aggressive action of chloride ions results in the selective character of the digestion of chromium-nickel steel. After the 11 week long exposure of the orthodontic components the concentration of chromium in the Ringer solution amounted to 0.10÷0.15 μg/dm3. while the maximum nickel content amounted to over 3 μg/dm3.
PL
Komercyjne elementy stałego aparatu ortodontycznego (druty, pierścienie i zamki) eksponowano w roztworze Ringera. Mikroanaliza rentgenowska (EDS) wykazała, że materiały wykonano ze stali chromowoniklowej. Obserwacje mikroskopowe (SEM) wykazały jedynie niewielkie zmiany powierzchni metalicznej elementów aparatu ortodontycznego podczas przetrzymywania w roztworze Ringera (77 dni). Skomplikowany kształt i niewielkie rozmiary pierścieni i zamków ortodontycznych uniemożliwiają przeprowadzenie badań potencjodynamicznych. Badania elektrochemiczne wykonano jedynie dla drutu ortodontycznego. Wykazały one, że maksymalna szybkość korozji drutu ortodontycznego w sztucznym płynie ustrojowym wynosi 2,1·10-6A/cm2. Agresywne działanie jonów chlorkowych skutkuje selektywnym charakterem roztwarzania stali chromowo-niklowej. Po 11-tygodniowej ekspozycji elementów ortodontycznych stężenie chromu w roztworze Ringera wynosiło ok. 0,10÷ 0,15 μg/dm3, przy maksymalnej zawartości niklu ponad 3 μg/dm3.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.