Conditions of determination of antimony(V) using anodic stripping voltammetry with differential pulse technique and hanging mercury drop electrode have been analyzed. Antimony was extracted from soils with HCl+HNO3 mixture (3:1). Deposition time was 15÷30 s, deposition potential –0.5 V and supporting electrolyte 3 M HCl. In the above conditions Sb(V) peak height vs its concentration dependence is linear up to 7·10–5 M antimony. The accuracy and precision of the proposed method is also satisfactory. The relative standard deviation for 1.5·10–7 M Sb(V) equals 7.5% and for 4·10–7 M Sb(V) equals 14.3%). The method has been applied to study the degree of contamination of soils in the vicinity of Huta Głogów copper smelter with antimony.
PL
W pracy opracowano metodykę oznaczania Sb(V) w ekstraktach glebowych, wykorzystując w tym celu woltamperometrię anodową. Antymon z gleb ekstrahowano mieszaniną HCl+HNO3 (3:1). Pomiarów dokonano w technice różnicowej pulsowej, stosując wiszącą rtęciową kroplową elektrodę. Elektrolitem podstawowym był 3 mol·dm -3 HCl. Czas zatężania wynosił 15÷30 s, potencjał zatężania –0,5 V wzgl. NEK. W tych warunkach krzywa kalibracji ma przebieg prostoliniowy aż do 7·10–5 mol·dm–3 Sb(V). Dokładność i precyzja opracowanej metodyki są zadowalające (względne odchylenie standardowe dla 1,5·10–7 mol·dm–3 Sb(V) wynosi 7,5%, dla 4.0·10–7 mol·dm–3 Sb(V) 14,3%). Opracowaną metodykę wykorzystano do oceny stopnia zanieczyszczenia antymonem terenów usytuowanych w zagłębiu miedziowym w pobliżu Huty Głogów.