Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  anion exchange resin
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The sediments of two lakes located in the Baltic Uplands, the western part of the East European Plain (East Lithuania and North East Poland), were studied. Activity concentration of 210Pb was determined using two nuclear analytical techniques: determination of 210Pb in equilibrium with its beta emitting daughter 210Bi using liquid scintillation counter (LSC), and direct determination of 210Pb (and other radionuclides) by low-background gamma-ray spectrometer with a well type HPGe detector. For the 210Pb determination by LSC the methodology of lead separation based on the anion exchange resin in Cl– form (Eichrom) was used. Several steps of radiochemical procedures and respective parameters were investigated additionally. The optimized procedures for LSC method were used for case study with two lake cores. The activity concentration of 210Pb in lake sediment samples based on both nuclear analytical techniques (LSC and HPGe) were compared. 210Pb dating of cores was performed according to Constant Rate of 210Pb Supply (CRS) model with some modifications. Both techniques in the range of uncertainties gave similar results. From two considered lakes, the more eutrophic one exhibited higher sediment mass accumulation rate (MAR) values.
PL
Omówiono zastosowanie procesu wymiany jonowej do usuwania z wody naturalnych makrocząsteczek organicznych. Możliwość ta wynika z faktu, iż znaczna część naturalnych substancji organicznych ma charakter makroanionów i stąd mogą być one usuwane na żywicach anionowymiennych. Także frakcja związków organicznych pozbawiona ładunku elektrycznego może zostać usunięta z wody wyniku adsorpcji na jonitach. Wykazano, że o skuteczności usuwania naturalnych substancji organicznych decydują m.in. właściwości fizyczno-chemiczne oczyszczanej wody, właściwości stosowanej żywicy oraz sposób realizacji procesu wymiany jonowej. Korzyści wynikające z wykorzystania wymiany jonowej do usuwania makrocząsteczek organicznych z wody to – oprócz bardzo wysokiej skuteczności – także minimalne wtórne zanieczyszczenie wody oraz bardzo niewielkie ilości odpadów wymagających zagospodarowania. Dodatkowo, coraz częstsze stosowanie tej techniki w układach oczyszczania wody wynika z faktu, iż koszty inwestycyjne i eksploatacyjne procesu wymiany jonowej są porównywalne do kosztów równie skutecznych metod oczyszczania wody ze związków organicznych, np. nanofiltracji lub adsorpcji na węglu aktywnym.
EN
Application of ion exchange process to removal of natural organic matter (NOM) from water was discussed. The majority of natural organic particles show properties of macroions and therefore they may be removed using anion exchange resins. Also, the fraction of organic compounds lacking electric charge may be removed from water using ion exchange adsorption. It was proved that efficiency of NOM removal depends, among others, on the physicochemical properties of water being purified, type and properties of the resin used as well as on the ion exchange method. The advantages of ion exchange process application to NOM separation from water include, apart from very high efficiency, minimum secondary water contamination and low amount of wastes to be disposed. Additionally, an increasing popularity of ion exchange in drinking water treatment results from investment and operating costs being comparable to costs of equally effective water treatment processes like nanofiltration or activated carbon adsorption.
PL
Określono skuteczność usuwania anionowej substancji powierzchniowo czynnej (ASPC) z grupy alkilobenzenosulfonianów (SDBS) na wybranych makroporowatych żywicach anionowymiennych. Oceniono skuteczność wymiany jonowej w zależności od początkowego stężenia ASPC w zakresie poniżej i powyżej krytycznego stężenia micelizacji, dawki żywicy jonowymiennej oraz jej czasu kontaktu z oczyszczanym roztworem. Na podstawie testów kinetycznych wyznaczono izotermy wymiany jonowej ASPC. Badania kinetyczne wykazały, że wymiana jonowa może być skutecznie stosowana do usuwania ASPC z roztworów wodnych. Skuteczność procesu rosła wraz z wydłużeniem czasu kontaktu żywicy z anionami SDBS oraz wraz ze wzrostem dawki zastosowanej żywicy. O skuteczności usuwania SDBS w procesie wymiany jonowej decydował rodzaj zastosowanej żywicy (stopień zdysocjowania grup funkcyjnych jonitu, wielkość ziaren jonitu oraz stopień usieciowania polimeru). Wykazano, że istotnym parametrem decydującym o skuteczności eliminacji ASPC w procesie wymiany jonowej była struktura polimeru decydująca o dostępności makrocząsteczek organicznych do miejsc aktywnych. Analiza modelu izotermy Langmuira pozwoliła następująco uszeregować testowane anionity wg zdolności wymiennej w stosunku do SDBS: MIEXŽ>SBW>A400>A200>A100.
EN
The anionic surfactant SDBS of the alkylbenzenesulfonate group was tested for the efficiency of removal on anion exchange resins of choice. The efficiency of ion exchange was assessed in terms of the following parameters: initial SDBS concentration within the range below and above the critical micellar concentration, dose of ion-exchange resin, and time of contact between the resin and the aqueous solution being treated. The ion exchange isotherms for the SDBS were determined by kinetic tests, which revealed that ion exchange was an efficient method of SDBS removal. The removal efficiency increased with the extension of the time of contact between the resin and the SDBS anions, and with the increase of the resin dose applied. The efficiency of SDBS removal via ion exchange depended primarily on the type of the resin applied (dissociation of the functional groups of the resin, grain size of the resin, cross-linking of the polymer). It was demonstrated that the main contributory factor in the efficiency of SDBS separation by ion exchange was the polymer structure, which had a decisive influence on the accessibility of the organic macromolecules to the active sites. Analysis of the Langmuir isotherm model enabled the anion exchange resin tested to be arranged in the following order (according to their exchange capacity with respect to SDBS): MIEXŽ>SBW>A400>A200>A100.
PL
W pracy zaproponowano rozwinięcie typowej procedury badań laboratoryjnych procesu magnetycznej wymiany anionowej o powtarzane testy kinetyczne i testy wielokrotne. Pozwoliło to na uwzględnienie w wynikach badań laboratoryjnych zmiennej charakterystyki wody surowej i jej wpływu na praktyczne możliwości oczyszczania wody metodą magnetycznej wymiany anionowej. Nowa procedura może spełniać część funkcji badań pilotowych, lecz ich w pełni nie zastępuje. Testom kinetycznym i wielokrotnym poddano wodę powierzchniową (Oława i Nysa Kłodzka) ujmowaną na potrzeby zaopatrzenia Wrocławia. W pierwszym przypadku określono teoretyczny zakres możliwości magnetycznej wymiany anionowej, a w drugim skuteczność tego procesu możliwą do uzyskania w praktyce. Otrzymane wyniki wskazują na potencjalnie duże możliwości usuwania substancji organicznych z badanej wody w procesie magnetycznej wymiany anionowej, osiągające 56÷71% w wypadku usuwania RWO oraz odpowiednio 73÷85% i 75÷82% w wypadku zmniejszenia intensywności barwy i absorbancji w UV254. Zmniejszeniu uległa również wartość absorbancji właściwej w UV (14÷51%). Praktyczna skuteczność metody była mniejsza, z uwagi na częściowe wysycenie (wyczerpanie) zdolności wymiennej żywicy wykorzystywanej w instalacjach technicznych. Wynosiła ona (w zakresie krotności wymiany żywicy 1000÷2000) odpowiednio 23÷50% (RWO), 33÷58% (barwa), 40÷57% (absorbancja w UV254) oraz 6÷33% (absorbancja właściwa w UV). Analiza wyników powtarzanych testów wielokrotnych może być także wykorzystana do wstępnego doboru parametrów procesu magnetycznej wymiany anionowej, a w szczególności zakresu preferowanych wartości krotności wymiany objętości żywicy, a ponadto informuje o możliwej reakcji układu oczyszczania na zmiany jakości wody surowej oraz możliwości ich buforowania poprzez regulację parametrów procesu.
EN
The study reported on in the paper aimed at developing the conventional laboratory procedure for magnetic anion exchange by the addition of the repeated kinetic jar test and multiple loading jar test. When such an approach is adopted, the results of laboratory investigations show how the changes in the quality of raw water influence the efficiency of water treatment by the magnetic anion exchange method. The procedure proposed performs certain functions of a pilot study, but can not replace it. In our research riverine water samples (from the Olawa and Nysa Klodzka, taken in for the municipal water supply system of the city of Wroclaw) were made subject to kinetic jar tests and multiple loading jar tests. Kinetic jar tests were used to determine the theoretical efficiency of organic anion exchange, whereas multiple loading jar tests were intended for establishing the efficiency of the process obtainable in practice. The results obtained have revealed a wide spectrum of possibilities for the application of magnetic anion exchange to the removal of organic substances from the riverine water being tested. The extent of theoretical dissolved organic carbon (DOC) removal varied from 56 to 71%, whereas the reduction in color intensity and UV254 absorbance fell in the range of 73 to 85% and 75 to 82%, respectively. A decrease was also observed in the specific UV absorbance value, which varied between 14 and 51%. However, the practical efficiency of the method was found to be lower, which is attributable to the partly exhausted exchange capacity of the resin used in technical installations. Thus, at a bed volume ranging between 1000 and 2000, actual removal efficiencies varied from 23 to 50% (DOC), from 33 to 58% (color), from 40 to 57% (UV254 absorbance) and from 6 to 33% (specific UV absorbance). Analysis of the results of repeated multiple loading jar tests may be of utility in the preliminary choice of the process parameters for magnetic anion exchange, but primarily in the choice of the range of preferred bed volume values. Moreover, analysis of the multiple loading jar test results provides information not only about the potential response of the treatment train to the variations in raw water quality, but also about the possibility of buffering such changes by the control of the process parameters.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.