EN
Spatio-Temporal Optical Coherence Tomography (STOC-T) is a novel imaging technique using light with controlled spatial and temporal coherence. Retinal images obtained using the STOC-T system maintain high resolution in all three dimensions, on a sample of about 700 μm, without the need for mechanical scanning. In the present work, we use known data processing algorithms for optical coherence tomography angiography (OCTA) and modify them to improve the rendering of the vasculature in the human retina at different depths by introducing the angio STOC-T method. The algorithms are primarily sensitive to the strong signal phase variance corresponding to the appearance of a wide Doppler band in STOC-T signals obtained for millisecond exposure times. After using STOC-T angiography, we can render high contrast images of the choroid.
PL
Autorzy przedstawiają nowatorskie rozwiązanie pozycjonera systemu angiograficznego zaprojektowane przez polskich konstruktorów.
EN
The authors present an innovative solution of the angiographic system positioner designed by Polish designers.
3
Content available Diagnostyka obrazowa okiem neurologa
PL
W diagnostyce chorób układu nerwowego dostępne jest szerokie spektrum metod diagnostycznych. Niektóre są wykonywane powszechnie, inne tylko w ośrodkach specjalistycznych. W opracowaniu poniżej omówiliśmy badania obrazowe stosowane w diagnostyce chorób neurologicznych. Szeroko omówiona diagnostyka w kontekście neurologicznym pozwala na uwypuklenie potrzeb, jakie istnieją w tym zakresie z punktu widzenia lekarza neurologa. Pokazano również wartości różnych badań dla różnych schorzeń neurologicznych. Praca ta nie może wyczerpać tematu, jakim jest diagnostyka obrazowa okiem neurologa, ze względu na rozległość tematyki. Założeniem jej jest dokonanie przeglądu dostępnych metod obrazowania i ukazanie ich wartości w leczeniu pacjentów.
EN
A wide spectrum of diagnostic methods are available in the diagnosis of nervous system diseases. Some are commonly performed, others only in specialist centers. In the study below, we discussed imaging tests used to diagnose neurological diseases. The broadly discussed diagnostics in the neurological context allow to highlight the needs that exist in this regard from the point of view of the neurologist. The values of various studies for various neurological diseases are also shown. This work cannot exhaust the topic of diagnostic imaging through the eyes of a neurologist due to the extent of the subject. Its assumption is to review the available imaging methods and show their value in treating patients.
PL
Wymogi prawa narzucają na personel obliczanie dawki pochłoniętej (w grejach) i odniesienie jej wartości do limitów określonych w Rozporządzeniu Ministra Zdrowia z dnia 18 lutego 2011 r. w sprawie warunków bezpiecznego stosowania promieniowania jonizującego dla wszystkich rodzajów ekspozycji medycznej. Celem pracy jest przybliżenie metodyki obliczania dawki pochłoniętej w grejach [Gy] na podstawie parametrów otrzymanych z rejestratorów dawki, na przykład kermy. Zastosowanie współczynnika korekcji, współczynnika BSF oraz wykorzystanie arkuszy kalkulacyjnych umożliwia szybką i prostą realizację zadań postawionych przez Rozporządzenie.
EN
Legal requirements impose on staff necessity of calculation of the absorbed dose (expressed in grays) and the reference of the value to the limits set out in the Regulation of the Minister of Health on 18 February 2011 on the conditions for the safe use of ionizing radiation for all types of medical exposure. The aim of this work is to present the methodology of calculation of the absorbed dose in grays [Gy] on the basis of parameters obtained from the dosage recorders, for example kerma. The usage of correction factor, BSF factor and spread sheets enables quick and easy implementation of tasks set by the Regulation.
5
Content available remote Wybrane zagadnienia z ultrasonografii
PL
Od kilkudziesięciu lat następuje szczególnie szybki rozwój badań diagnostycznych metodą ultradźwiękową. Badania te pozwalają uzyskać w sposób nieinwazyjny i dla pacjenta nieszkodliwy wiele cennych informacji o strukturach biologicznych, ich topografii, a także fizjo- i patofizjologicznych zjawiskach w organizmie człowieka. W dzisiejszych czasach można za pomocą ultradźwięków wykonywać badania angiograficzne (nieinwazyjne!) przy nieporównanie niższej cenie aparatu.
EN
In the paper some problems of ultrasonography application in medical diagnostic have been described. Examination types and their development are discussed.
EN
Many studies concerning evaluation of the artery blood flow based on coronarographic images have been made. Application of the indicator-dilution technique allows calculation of absolute values of the blood flow in the coronary arteries based on the densitometric analysis of coronarographic image sequences under some specific conditions imposed on injections of the contrast medium and digital image sequences registration. This method is based on densitometric measurements carried out in two sequences of images of the same artery. The first sequence is recorded during the routine injection of the contrast, and the other is recorded during the slow test injection of the contrast with a reduced amount of the indicator. The method was tested on coronarographic images obtained in routine examinations in two groups of control patients. The comparative analysis of 18 patients indicates that there exists a moderate consistency between the results of this method and the clinical assessment. The results of our studies are strongly dependent on the accuracy of the measurements and the method of recording. Proposed method, tested on the model of artery and measurements obtained from coronarographic examinations of control groups of patients, provides grounds for future studies.
EN
The Department of Angiology of Jagiellonian University did research on the treatment of critical limb ischemia with bone-marrow transplantation. Extensive tests of objective and subjective examinations were conducted to evaluate the efficacy of the treatment. One of these test procedures - the analysis of vascular net density in angiographic imaging was supported by quantitative image analysis methods. Angiographic videos made before and after intervention were converted to image sequences. Analyzed images revealed translation of blood vessels in XY plane and differences in brightness. The normalized cross correlation method was used to find the translation vector. The developed image processing algorithm involves initial filtration, top-hat operation, automatic threshold and final filtration of all angiographical images. Volume increment of blood flow per time unit and the length of blood vessels were duly analysed on the segmented images. Further investigations of many patients' angiographical videos, with different parts of the blood system are still required to fully verify the adequacy of the algorithm as a tool supporting the doctor's decisions.
PL
Jednym z kryteriów oceny terapii choroby niedokrwiennej kończyn dolnych jest analiza gęstości netto naczyń krwionośnych w obrazach angiograficznych przy pomocy ilościowej analizy obrazów. Angiograficzne filmy wideo wykonane przed i po interwencji zostały zamienione na postać sekwencji obrazów, a następnie poddane obróbce cyfrowej. Przeprowadzono analizę wzrostu objętości przepływającej krwi w jednostce czasu oraz długości naczynia na podstawie segmentowanych obrazów.
EN
A methods is proposed for generation of the centerline of 3D tubular shapes using an extensible-skeleton model. Starting from a user-selected point, the skeleton grown by iteratively adding subsequent centerline points within a prediction-estimation scheme controlled by a multi-scale analysis of the image moments. The location of the next point is predicted according the local orientation of the tubular structure. The coordinates of the predicted point are corrected under the influence of image forces and of prior model shape constraints. The extraction of artery centerlines from magnetic resonance angiography (MRA) images is described. The goal is a quantitative assessment of arterial stenoses based on cross-sectional diameters and areas of the vessel contours in the planes locally perpendicular to the centerline. For this purpose, iso-contours extraction based on an adaptive local iso-value have been implemented. The robustness and accuracy of the method have been demonstrated on MRA data on 5 reference phantoms and on 17 patients' carotid arteries. 97% of the centerlines were exploitable in the carotid arteries (100% in the phantoms). On average, the centerlines were extracted within 1 second, and the whole quantification process took less than 1 minute per artery, including interaction and display. The Mean difference (± standard deviation) between stenosis percentages, semi-automatically measured and visually estimated by radiologists, was 0,23% ± 7.89%. The reproducibility of the semi-automatic method was significantly better.
9
Content available remote Metoda pomiaru przepływu krwi w organizmie człowieka
PL
W artykule zaprezentowano metody pomiaru przepływu krwi w organizmie człowieka. W metodach ultrasonograych i angiograficznych zaprezentowano dodatkowo projekcje filmowe z badań medycznych. Przedstawiono również medyczne i fizyce aspekty dotyczące zaburzeń w przepływie wywołanych zwężeniami oraz tętniakami.
EN
The article was to present all methods of measurement of blood flow in a human body. Some of them use medical film material from ultrasonography and angiography. In that examinations it was to show the medical and physical aspects of velocity blood flow changes, closed by contractions or aneurisms in blood vessels. An application of computer methods of image analysis for examination velocity of blood flow was presented.