1
Content available Badanie filtrów analogowych
PL
W pracy przedstawiono stanowisko do badania filtrów analogowych. Zaproponowano rozwiązanie software’owe wspomagające analizę uzyskiwanych wyników, a także pokazano wyniki charakterystyki sygnału dla wybranych ustawień zaprojektowanych wcześniej filtrów analogowych. Dokonano interpretacji uzyskanych wyników, a także przedstawiono wnioski wynikające z tej interpretacji.
EN
The paper presents a laboratory station for testing analog filters. A software solution, which is responsible for supporting the analysis of obtained results, was proposed. It is shown results of signal characteristics for selected settings of previously designed analog filters. The obtained results were interpreted and lead to conclusions.
PL
Pomiary różnych wielkości fizycznych dokonywane są najczęściej w ten sposób, że najpierw wartości chwilowe mierzonych wielkości są przetwarzane na wartości chwilowe napięcia elektrycznego, po czym sygnał napięciowy jest przesyłany torem pomiarowym do przetwornika analogowo-cyfrowego. W praktyce pomiarowej zdarza się jednak, że nie przykłada się należytej uwagi do zagadnień filtracji sygnałów w torach pomiarowych, albo filtracja ta jest przeprowadzona w niewłaściwy sposób. W referacie dokonana została analiza wpływu analogowej filtracji dolnoprzepustowej na parametry sygnałów użytecznych i zakłócających w torach pomiarowych. W pierwszej kolejności określono wpływ takiej filtracji z wykorzystaniem biernego filtru RC I rzędu w warunkach pracy bez obciążenia i z obciążeniem na wyjściu filtru. Następnie porównana została praca biernych filtrów RC I, II i III rzędu. Ponieważ skuteczność działania filtrów biernych jest często niewystarczająca, dlatego przedstawiono przykładowe działanie filtrów aktywnych wyższych rzędów.
EN
Measurements of various physical quantities are usually performed so at first instantaneous values of the measured quantity are converted into instantaneous values of the electrical voltage, and then this voltage signal is transmitted to the analog-to-digital converter through the measurement channel. However – in the measurement practice – it happens, that inadequate attention is paid to the issues of the signal filtering in measuring channels, or this filtering is performed in an improper manner. In this paper has been presented an analysis of the analog low-pass filtering impact on the useful signal parameters and noise signal parameters in the measurement channels. First, there has been analyzed an influence of this low-pass filtering using a 1st order RC filter with no load and with load at the filter output. Then there has been compared an operation of passive RC filters of the 1st, 2nd and 3rd order. Since the operational efficiency of the passive filters is often insufficient, there has been provided an example of the higher order active filters operation.
3
Content available remote Performance assessment of "Field programmable analog arrays"
EN
Field Programmable Analog Arrays (FPAAs) are reconfigurable analog modules introduced on the electronic market in the last decade. Their operation and, in particular, their programmability is achieved owing to the use of switched capacitors technology. At least in principle, they seem to be a very attractive and powerful tool to design analog circuits whose parameters have to be tuned to signal variations as in carrying out sensor conditioning systems. But the aim of exploiting their possibilities in the field of metrology requires complete characterization and performance assessment of the involved building blocks. With this goal, in the paper, the metrological characterization of the most commonly blocks to be used in analog conditioning circuits, such as amplifiers and filters, is performed. These blocks have been characterized in terms of both frequency response and step response and the obtained experimental results have been compared with those expected from theoretic analysis. Concluding remarks are then deduced to furnish practical hints in the use of FPAAs in measurement applications.
PL
Opisano szczegółowo bloki funkcjonalne, pozwalające na syntezę szerokiej klasy filtrów analogowych w czasie ciągłym, odpowiednich do realizacji we współczesnych i przyszłościowych niskonapięciowych technologiach CMOS. Istotą proponowanego rozwiązania jest wykorzystanie inwertera CMOS oraz luster prądowych typu high-swing. Jako przykład wykorzystania realizacji układowej przedstawiono syntezę dolnoprzepustowego filtru eliptycznego szóstego rzędu.
EN
The paper describes a complete set of building blocks sufficient for synthesis of relatively wide class of low voltage current mode continuous time analog filters. The core of proposed implementation exploit CMOS inverters and high swing current mirrors. As an example the synthesis of a six order elliptic lowpass filter is presented.
5
Content available remote Analog Filter Design System for Field Programmable Analog Array
EN
An object oriented system for automatic design of cascade and symmetrical Follow-the-Leader Feedback (FLF) filters using OTA-C (Operational Transconductance Amplifier with Capacitor) biquad blocks with dynamic range, distortion and sensivity optimization is presented. The system enables realization of standard Butterworth and Chebyshev amplitude approximations and arbitrary, user-defined amplitude characteristics.