The response of the full-scale three-loop Pressurized Water Reactor (PWR) RELAP5 computational model on Steam Generator Break Rupture (SGBR) was investigated in this paper. This model was analyzed in terms of its applicability and performance regarding the research task conducted by Warsaw University of Technology and the National Center for Research and Development inWarsaw, Poland. In the paper break sizes corresponding to one, three and six ruptured tubes (which conform to a Loss-of-Coolant event break size area of 0.02%, 0.054 and 0.11%) were studied at three different locations (at the top of the hot-leg side tubesheet, U-bend and at the top of the cold-leg side tubesheet). The reactor at issue was a three-loop PWR of Westinghouse design with thermal output of 2775 MWt.