The influence of sudden and gradual temperature fluctuations on the stability of partial nitritation applied for the treatment of reject water containing ammonium nitrogen (NH4+-N) in the range of 1000 –1400 mg/dm3 was investigated. It was found that a sudden decrease in temperature from 24.3 °C to 14.3 °C and 15.8 °C significantly affected the stability of the process. No negative effect was recorded after a sudden temperature decrease from 24.3 to 17.4 °C. It was also found that during a gradual temperature decrease from 24.3 °C, process stability was negatively affected at 12.7 °C.
Efektywne oczyszczanie ścieków jest podstawowym priorytetem każdej oczyszczalni ścieków. Wymagania prawne zgodnie z Rozporządzeniem Ministra Środowiska (Dz.U. 2009 nr 27 poz. 169) dotyczą nie tylko związków organicznych (BZT5, ChZT) i zawiesin ogólnych ale również wysokoefektywnego usuwania związków biogennych: azotu i fosforu. W pracy przedstawiono ocenę efektywności pracy oczyszczalni ścieków komunalnych w Kostrzynie nad Odrą w zakresie usuwania zanieczyszczeń organicznych i związków azotu. Wykazano, że uzyskanie w ściekach oczyszczonych stężeń azotu ogólnego mniejszych od 10 mg/dm3 nie jest realizowane w klasycznym układzie nitryfikacja-denitryfikacja. Wyznaczone parametry takie jak: BZT5/TKN w komorze denitryfikacji (0,9-2,7), N-NH4/N-NO3 (średnio 0,67) niskie stężenie tlenu oraz niska podaż substratu organicznego wskazują na przebieg procesu anaerobowego utleniania amoniaku.
EN
Effective treatment of wastewater is a basic priority of each and every wastewater treatment plant. Legal requirements in accordance with the Decree of the Minister of the Environment (Journal of Laws 2009 No. 27, item. 169) include not only organic compounds (BOD5, COD) and general suspensions but also highly effective removal of nutrients: nitrogen and phosphorus. This paper presents an assessment of the efficiency of wastewater reatment plant in Kostrzyn in removal of organic and nitrogen compounds. It has been shown that the nitrogen concentrations <10 mg/l obtained in treated wastewater is not carried in the classical nitrification-denitrification system. The obtained parameters: BOD5/TKN ratio in the ef-fluent in denitrification chamber from 0.9 to 2.7, the average value N-NH4/N-NO3= 0.67, low oxygen and low supply of organic substrate suggest anaerobic oxidation of ammonia.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.