Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  ambient conditions
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The present study examines some durability aspects of ambient cured bottom ash geopolymer concrete (BA GPC) due to accelerated corrosion, sorptivity, and water absorption. The bottom ash geopolymer concrete was prepared with sodium based alkaline activators under ambient curing temperatures. The sodium hydroxide used concentration was 8M. The performance of BA GPC was compared with conventional concrete. The test results indicate that BA GPC developes a strong passive layer against chloride ion diffusion and provides better protection against corrosion. Both the initial and final rates of water absorption of BA GPC were about two times less than those of conventional concrete. The BA GPC significantly enhanced performance over equivalent grade conventional concrete (CC).
PL
W przypadku proponowania oraz dostosowywania popiołu dennego jako materiału źródłowego w betonie geopolimerowym, ważne jest, aby oprócz jego właściwości wytrzymałościowych, zapewnić jego wydajność w odniesieniu do aspektów trwałości. Jak wynika z poprzednich badań, należy rozumieć, iż istnieje luka w pewnym wykorzystywaniu betonu geopolimerowego na bazie popiołu dennego. W związku z tym, w niniejszej pracy zbadano wydajność betonu geopolimerowego na bazie popiołu dennego pod kątem przyspieszonej korozji, sorpcyjności oraz absorpcji wody. W odniesieniu do proporcji mieszanki, klasa betonu została zaprojektowana dla 40 MPa. Do wywołania reakcji geopolimerycznych zastosowano aktywatory chemiczne na bazie sodu. Ilość roztworu chemicznego została przyjęta jako 0,5-krotność masy materiału źródłowego. Zachowanie betonu geopolimerowego na bazie popiołu dennego porównano z typowym betonem cementowym. Badania wytrzymałościowe wskazują, że beton geopolimerowy na bazie popiołu dennego wykazał większą wytrzymałość niż beton cementowy. Podczas gdy kilku badaczy zaleca utwardzanie termiczne w celu aktywacji betonu geopolimerowego, na tym etapie można stwierdzić, że beton geopolimerowy na bazie popiołu dennego osiągnął wytrzymałość przy utwardzaniu w temperaturze otoczenia. Ze względu na przyspieszoną korozję, czas rozpoczęcia korozji betonu geopolimerowego na bazie popiołu dennego został wydłużony 1,76 razy w porównaniu z betonem cementowym. Beton geopolimerowy na bazie popiołu dennego tym samym zwiększył bardziej katodową reakcję oraz zmniejszył aktywność korozyjną ze względu na wzmocniony proces reakcji polimerowej. Ze względu na efekt wypełniacza mikrocząsteczek popiołu dennego, a także reakcję geopolimeryzacji pomiędzy popiołem dennym a aktywatorami alkalicznymi, betonowi geopolimerowemu na bazie popiołu dennego przypisano wyraźnie niższą sorpcyjność. Natomiast wyższa wytrzymałość na ściskanie betonu geopolimerowego na bazie popiołu dennego wykazała niższą absorpcję wody. Można zatem stwierdzić, że beton geopolimerowy na bazie popiołu dennego utwardzony w temperaturze otoczenia jest uznawany za wysoce wytrzymały materiał kompozytowy.
2
Content available remote Analiza matematyczna pracy prostej turbiny gazowej po zmianie paliwa
PL
Zastosowanie biomasy do produkcji energii elektrycznej z użyciem turbin gazowych małej mocy wymaga opracowania modeli maszyn i urządzeń o odmiennej charakterystyce w stosunku do szeroko rozpowszechnionych układów lotniczych i przemysłowych wykorzystujących paliwa konwencjonalne. W celu wskazania najistotniejszych zagadnień związanych z opracowaniem nowych rozwiązań dla turbin gazowych zasilanych paliwem z biomasy, w artykule przedstawiono analizę matematyczną pracy prostej turbiny gazowej małej mocy po zmianie paliwa. W szczególności zwrócono uwagę na możliwość wystąpienia pompażu, przekroczenia dopuszczalnych prędkości obrotowych oraz mocy. Przedstawiono również analizę parametrów komory spalania po zmianie paliwa.
EN
The use of biomass to produce electricity using gas turbines requires the development of models with different characteristics in relation to the widespread aero and industrial systems using conventional fuels. In order to identify the most important issues related to the development of new solutions for gas turbines fueled with biogas, in the article, the mathematical analysis and models of the operation of the simple gas turbine after the change of fuel are shown. In particular, attention was paid to: possibilities of surging occurrence and exceeding the permissible speed and power. An analysis of the parameters of the combustion chamber after the change of the fuel was shown.
EN
Modern marine Diesel prime movers are equipped with so called ‘common rail’ as a part installed in the fuel injection system. This kind of design, gives a possibility to control fuel injection process in ways which were not available to carry out on conventionally designed engines. During the ship operation with a reduced speed and reduced load of the main engine, especially under the “Super Slow Steaming” conditions the waste heat recovery process in exhaust gas boiler is being disturbed. In the article, there is presented a possibility to increase the steam production of the waste heat boiler by interference in the fuel injection pattern for the engine. For the selected system “low speed main engine – smoke tube exhaust gas boiler” the test session has been carried out under the real ambient and operational condition of the ship to verify described possibility. Obtained results have been presented.
4
EN
A modal filter is an excellent indicator of damage detection, with such advantages as low computational effort due to data reduction, ease of automation and low sensitivity to environmental changes [4,5]. However to apply it in a real SHM system, it first needs to be extensively tested to verify its sensitivity to damage location, inaccuracy of sensor location in the consecutive experiments, measurements noise as well as changes in ambient conditions, such as temperature and humidity. This paper presents the results of numerical simulations that test the sensitivity of the modal filter based damage detection method to the factors listed above. For this purpose three numerical models of the physical systems were created and applied.
PL
Filtr modalny jest bardzo dobrym wskaźnikiem wykrywającym uszkodzenie, posiadającym takie zalety jak niewielkie wymagania obliczeniowe, łatwość automatyzacji procedury i niska wrażliwość na zmiany warunków zewnętrznych [4,5]. Jednakże, aby zastosować go w rzeczywistym układzie monitoringu musi najpierw przejść szczegółowe badania symulacyjne w celu weryfikacji jego wrażliwości na takie czynniki jak lokalizację uszkodzenia, niedokładność umieszczania czujników w kolejnych pomiarach, zakłócenia toru pomiarowego oraz zmiany warunków otoczenia takich jak temperatura i wilgotność. W pracy tej przedstawiono wyniki weryfikacji symulacyjnej, sprawdzającej wpływ powyższych czynników na wyniki filtracji modalnej. W tym celu sporządzone zostały i zastosowane trzy modele numeryczne.
5
Content available remote Analiza rozkładu temperatury w kiełkowniku nasion
PL
W artykule przedstawiono obliczenia cieplne rezystancyjnego kiełkownika nasion, który został wykonany w Instytucie Podstaw Elektrotechniki i Elektrotechnologii. Kiełkownik jest ogrzewany niskotemperaturowymi elementami rurkowymi, które znajdują się pod zbiornikiem z wodą i umożliwiają uzyskanie temperatury wody 30°C. W pracy pokazano rozkłady temperatury w poszczególnych elementach kiełkownika przy przyjętej mocy elementów grzejnych w zależności od warunków otoczenia. Wyniki obliczeń zostały porównane z wynikami badań kiełkownika nasion, który znajduje się w eksploatacji w Laboratorium Okręgowego Inspektoratu Inspekcji Nasiennej w Lublinie.
EN
The paper presents heating calculations of the resistive seed germination apparatus that was designed at the Institute of Electrical Engineering and Electrotechnologies. The germination apparatus is heated with low-temperature tubular units assembled under the water container and enables to obtain the water temperature of 30° C. The presented article shows temperature distributions at the respective elements of the germination apparatus at adopted power of the heating units in dependence on the ambient conditions. The results were then compared with the calculations of the investigation carried out on the germination apparatus operating at the laboratory of the District Seed Quality Inspection in Lublin.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.