Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  aktywna termografia podczerwona
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The simple method of determining thermal diffusivity of solid materials at room temperature using the pulsed infrared thermography (IRT) is proposed. The theoretical basis of the method and experimental results are presented. The study was conducted on austenitic steel 316L. Theobtained results show that the thermal diffusivity value of the tested steel determined by means of pulsed infrared thermography is very approximate to the values given in the literature, obtained by using more complicated methods. The differences between these values are 0.5%.
PL
W niniejszej pracy przedstawiono prostą metodę wyznaczania dyfuzyjności cieplnej ciał stałych w temperaturze pokojowej przy wykorzystaniu aktywnej termografii podczerwieni. Zaprezentowane zostały teoretyczne podstawy metody oraz wyniki badań doświadczalnych. Badanie przeprowadzono dla stali austenitycznej 316L. Otrzymane rezultaty pokazują, że wyznaczona wartość dyfuzyjności cieplnej badanej stali jest bardzo bliska wartościom podanym w literaturze, otrzymanym za pomocą bardziej skomplikowanych metod. Różnica między tymi wartościami sięga zaledwie 0,5%.
PL
W pracy przedstawiono wyniki zastosowania aktywnej termografii podczerwonej z wymuszeniem mikrofalowym do wykrywania zakopanych w piasku ćwiczebnych min przeciwpiechotnych: PMN, PMN-2 oraz PMF-1. Wspomniane miny mają obudowy wykonane z tworzyw sztucznych oraz odznaczają się niską zawartością metalu, przez co są trudno wykrywalne standardowymi wykrywaczami metalu. Prezentowana nowa metoda wykrywania min lądowych wykorzystuje źródło mikrofal o dużej mocy do podgrzania gruntu wraz z zakopaną w nim miną. Wytworzona różnica temperatur jest obserwowana na powierzchni gruntu za pomocą czułej kamery termowizyjnej.
EN
In this paper, active infrared thermography is used to detect antipersonnel landmines: PMN, PMN-2 and PMF-1. Mentioned landmines have very low metal content and their casings are made of plastic, therefore are considered as hard to detect using metal detectors. Presented new method of landmines detection, uses high power microwave source to heat the ground with buried landmine. Obtained temperature difference can be observed on the ground surface with sensitive thermovision camera.
PL
Aktywna termografia podczerwona jest techniką często stosowaną przy nieniszczącym testowaniu różnorakich struktur. Ze względu na wolumetryczny charakter podgrzewania mikrofalowego, proponujemy użycie mikrofal do indukowania różnic temperatur w badanych obiektach. Opracowany układ eksperymentalny jest prototypowym segmentem bazowym urządzenia do wykrywania niemetalicznych min lądowych. Niniejszy artykuł prezentuje rezultaty zastosowania algorytmów progowania do otrzymanych termogramów. Opracowana metoda pozwoliła na detekcję obiektów symulujących miny lądowe z obrazów prezentujących rozkład temperatur.
EN
Infrared thermography, using external excitation source, is one of the most popular methods used in non destructive testing. Due to volumetric character of microwave heating phenomena, in our system, the temperature difference is induced using microwave radiation. Developed setup is used to detect the nonmetallic landmines. In this paper results of thermogram analysis using thresholding algorithm is presented. Described method allowed to detect the landmines' simulants in termographic pictures.
EN
The active infrared thermography, using microwaves as the external energy source is a relatively new NDT technique. Differences in electric and thermal properties of materials allow to detect the examined specimens' "defects". In this paper, the above method's application to landmines' detection will be considered. The experimental setup has been optimized to obtain better performance of microwave heating. The proper waveguide's flange, obtained by the optimization process, has been used to produce thermal pattern characterized by uniform temperature distribution. In this article several numerical models, developed by using the finite element method, will be presented and applied to the optimized setup efficiency testing.
PL
Aktywna termografia podczerwona z wymuszeniem mikrofalowym jest stosunkowo nową techniką badań nieniszczących. Różnice we własnościach elektrycznych i temperaturowych materiałów pozwalają na detekcję defektów w badanych próbkach. W niniejszym artykule zostanie rozważona możliwość zastosowania wymienionej techniki do wykrywania niemetalicznych min lądowych. Laboratoryjny układ badawczy został zoptymializowyany w celu otrzymania lepszych parametrów grzania mikrofalowego. Odpowiedni kołnierz falowodu, którego wymiary zostały ustalone w procesie optymalizacyjnym, został użyty w celu otrzymania sygnatury termicznej charakteryzującej się jednorodnym rozkładem temperatury. W tym artykule autorzy zaprezentują modele numeryczne opracowane przy użyciu metody elementów skończonych. Przedstawione zostanie zastosowanie sporządzonych modeli to testów efektywności zoptymalizowanego układu badawczego.
PL
Technika aktywnej termografii podczerwonej jest jedną z najpopularniejszych metod wykorzystywanych w badaniach nieniszczących. Proponowanym przez nas źródłem ciepła indukującym różnicę temperatur w badanym obiekcie jest generator mikrofal wysokiej mocy. Opracowany układ grzewczo - detekcyjny jest segmentem bazowym urządzenia do wykrywania niemetalicznych min lądowych. Niniejszy artykuł prezentuje rezultaty zastosowania metod przetwarzania obrazów do analizy otrzymanych termogramów. Przy użyciu metody wykorzystującej interpolację biliniową oraz metodę wirtualnego przesunięcia kamery z termogramów zostały usunięte zniekształcenia perspektywiczne.
EN
Active infrared thermography is one of the most popular methods used in non destructive testing. In our system, the temperature difference is induced using microwave radiation. Developed setup is used to detection of the nonmetallic landmines. In this paper we present the results of thermograms analysis using image processing algorithms. The method using bilinear transformation and virtual camera shifting were used to remove the perspective distortions.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.