EN
The article discusses the requirements for determining airborne sound insulation according to ISO 10140-2, which involves measuring sound pressure levels in the source (L1) and receiving (L2) rooms, as well as reverberation time measurements in the receiving room. The size of the free test opening and the equivalent sound absorption area in the receiving room affect the value of L2. While ISO 10140-5 specifies the dimensions of a full-size test opening, reduced-size openings can also be used. However, testing reduced-size baffles with specific dimensions may be necessary, and measurements on rectangular-shaped baffles may yield higher sound reduction indices than square-shaped ones. The article presents a comparative analysis of the spectral characteristics of different types of single homogeneous baffles with various dimensions using experimental methods. It examines the measurement methodology's influence on determining sound insulation spectra and the weighted sound reduction index Rw. The article also calculates the combined uncertainty in determining the sound insulation properties and partial uncertainties in determining L1 and L2.
EN
The article presents the results of field measurements of apparent sound insulation between office rooms separated by a lightweight skeleton wall with plasterboard cladding and mineral wool filling. The tests were carried out in the same office rooms, but the connection method of the wall with the façade post was changed. Thanks to this, the impact of the connection method of the wall with the post on sound insulation between the rooms was determined. In addition, the measurements were repeated for the "best" connection variant, but only after the completion of the finishing stage of the rooms. The finishing works consisted in the construction of raised floor and suspended ceiling, laying floor covering and furnishing. Additional service ducts between the rooms were also made during this stage. The effect of these works had a significant impact on the reduction of sound insulation. The article presents potential causes of this phenomenon.
EN
The main problem in the measurement of airborne sound insulation is the measurement of the sound power radiated by the barrier, in practice performed by measuring the sound pressure level and the acoustic absorption in the receiving room. Large variations of the sound pressure level in a reverberation room indicate the presence of dominating strong standing waves, so that it becomes necessary to install diffusing elements. In ISO 10140, the limits have been defined in which the reverberation time at frequencies at and above 100 Hz should be included. Sometimes, however, in the case of rooms with a large volume, obtaining the required parameters is difficult and sometimes even impossible. It should then be checked whether the measured sound insulation depends on the reverberation time. The paper presents the results of sound insulation measurements at various reverberation time lengths in subsequent stages of diffusing elements installation in the receiving room. An analysis of diffusing materials amount and arrangement influence on the uniformity of the sound pressure level distribution and reverberation time in the room as well as the value of the measured sound insulation was carried out. Uncertainty of sound insulation measurement with partial uncertainties was adopted as a criterion supporting the assessment of the obtained results.
PL
Na izolacyjność akustyczną w budynkach wpływa wiele czynników związanych z drogami przenikania dźwięku między pomieszczeniami. Należą do nich tzw. droga bezpośrednia zależna od izolacyjności akustycznej przegród rozdzielających dane pomieszczenia, materiałowe drogi przenoszenia bocznego oraz powietrzne drogi pośrednie wynikające z transmisji dźwięku przez wszelkiego rodzaju nieszczelności oraz dodatkowe kanały (np. instalacyjne) łączące pomieszczenia. W referacie przeanalizowano wpływ tych czynników na izolacyjność akustyczną w budynkach mieszkalnych wielkopłytowych. Uwzględniono przy tym szczególnie te czynniki, które są charakterystyczne dla budownictwa prefabrykowanego. W referacie wykorzystano wyniki badań laboratoryjnych i terenowych przeprowadzonych przez Zakład Akustyki w latach 1975-85.
EN
The sound insulation in buildings is affected by many factors related to various sound transmission paths between rooms. Among them the following paths can be distinguished: the so called direct path dependent on the sound insulation of the partition between rooms, the structural flanking transmission paths and additional airborne paths due to sound transmission though leaks and ducts linking the rooms (e.g. ventilation ducts). The paper analyzes the influence of these factors on sound insulation in multifamily, prefabricates buildings. Laboratory and field measurement results made by ITB’s Acoustic Department in the period of 1975-85 are presented.
PL
Artykuł prezentuje wykonaną modyfikację stanowiska do badania izolacyjności akustycznej przegród, umożliwiającą przeprowadzanie badań dla próbek o wymiarach 0,7 x 0,7 m. Stanowisko wykonano i przetestowano w ramach realizacji projektu rozwojowego poświęconego opracowaniu i przebadaniu właściwości akustycznych warstwowych przegród (gumowo-metalowych) dźwiękochłonno-izolacyjnych, przydatnych w rozwiązaniach zabezpieczeń wibroakustycznych.
EN
The paper presents the modifications conducted on a stand used to test sound insulation of partitions, allowing to carry out tests for samples sized 0,7 x 0,7 m. The stand was built and tested as a part of the implementation of a development project dedicated to the preparation and testing of acoustic properties for laminated sound absorption and insulation partitions (rubber-metal) useful in vibroacoustic protection systems.
EN
Outdoor noise barrier is roadside noise reducing device, the primary task of which is the protection of a pre-determined sound protection area against road traffic noise. The examinations of acoustic properties of the ele-ments used for construction of noise barriers are usually carried out in laboratory conditions according to the PN-EN 1793-1,2 standard. These examination procedures cannot be applied to existing installations. Therefore problems that are usually neglected are the problems related to the acoustic properties that essentially depend on a series of factors unrelated to the building elements themselves, namely: barrier dimensions, quality of workman-ship, barrier location and the type and topography of the ground foundation. In the European Research Project "Adrienne" a methodology has been elaborated for in-situ determination of acoustic parameters of noise barriers. The examination, in which analysis of the system's impulse response after MLS signal actuation and a proper numerical algorithm are applied, leads to determination of airborne sound insulation of the existing constructions as well as the single number sound reflection factors and differences of diffraction properties at the top-edge elements of the barriers. The present paper describes the possibilities of determination of the intrinsic characteristics of airborne sound insulation index for the road traffic noise reducing devices in free field conditions and the determination of single number rating of airborne sound insulation to indicate the performance of the noise barrier.
PL
Ekran akustyczny jest drogowym urządzeniem przeciwhałasowym, którego zasadniczym zadaniem jest ochrona przed hałasem komunikacyjnym terenów chronionych akustycznie. W warunkach laboratoryjnych badania właściwości akustycznych elementów do budowy ekranów akustycznych prowadzone są według wymagań norm PN-EN 1793-1,2. Tych procedur badawczych nie można zastosować do instalacji już wybudowanych. Zatem pomijany jest problem dotyczący właściwości akustycznych, które zależą od wielu czynników, niezwiązanych tylko z wyrobem budowlanym, takich jak: wymiary ekranu, jakość wykonania, usytuowanie i związane z tym rodzaj oraz geometria podłoża. W ramach europejskiego projektu "Adrienne" opracowano metodykę wyznaczania parametrów akustycznych ekranów w warunkach in situ. Pomiary, w których wykorzystuje się analizę odpowiedzi impulsowej układu przy pobudzeniu sygnałem MLS i odpowiedni algorytm obliczeniowy, prowadzą do wyznaczenia izolacyjności akustycznej rzeczywistych konstrukcji oraz jednoliczbowych wskaźników odbicia dźwięku i różnicy dyfrakcji dla krawędziowych elementów ekranów. W pracy przedstawione są możliwości wyznaczania charakterystyk rzeczywistych izolacyjności akustycznej od dźwięków powietrznych dla drogowych urządzeń przeciwhałasowych w warunkach terenowych i wyznaczenia jednoliczbowego wskaźnika oceny izolacyjności akustycznej.