Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  airborne microorganisms
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The article presents the results of microbiological and microclimatic research carried out in a large maze Zoloushka Cave (Ukraine-Moldova). The cave was artificially exposed during the exploitation of the gypsum quarry founded in the late '40s of the last century. Until the cave labyrinth was opened by the quarry, the underground system of cavities had been almost completely filled with water and constituted a natural part of the rich in water karst aquifer. The cave became exposed while being at the stage of its active formation, and its artificial dehydration enabled researchers to observe the ('accelerated') course of various processes associated with the transition of the caves from the watered (freatic) stages to vadose and dry. Microbiological analyses aimed to determine the number of microorganisms (heterotrophic bacteria, Actinobacteria, and fungi) present in the air of the cave in two seasons – summer and winter. Microclimatic study aimed to determine the thermal, humidity and circulation characteristics of the cave microclimate The rules of occurrence of microorganisms in temporal and spatial (within a cave) cross-sections and the relative role of external and internal (cave) factors in shaping of the microbiological "image" of cave air were established. The stability of the microclimate (ecological) conditions in the cave in the course of the year allows the conclusion that most of the microorganisms come from the outside and enters the cave during the exchange of the air with the external environment. Nevertheless, the environment of the cave does not remain passive – it makes the air contents spatially (within the cave field) diverse and, in some cases, it determines them (in places of significant anthropogenic pollution of the cave, which probably facilitates the growth of fungi). The measurements have shown that the total number of the studied groups of microorganisms in the air of the cave varies in the course of year within the following ranges: heterotrophic bacteria 48-2,630 cfu·m-3, fungi 80-3,395 cfu·m-3, and Actinobacteria 5-51 cfu·m-3. Mean values of the microbial aerosol concentrations with respect to the entire cave are: heterotrophic bacteria – 353 cfu·m-3, fungi – 974 cfu·m-3, and Actinobacteria – 17 cfu·m-3. In general, there is a regularity of an increase in their concentration during the warm period: 3-5 times higher values for bacteria (48-764 cfu·m-3 in winter and 175-2630 cfu·m-3 in summer), 4-5 times for fungi (80-990 cfu·m-3 in winter and 390-3395 cfu·m-3 in summer), and 0-1 times for Actinobacteria (0-51 cfu·m-3 in winter and 5-55 cfu·m-3 in summer).
PL
Artykuł prezentuje wyniki badań mikrobiologicznych i mikroklimatycznych przeprowadzonych w dużej labiryntowej Jaskini Zołuszka (Ukraina-Moldowa). Jaskinia została odkryta podczas eksploatacji gipsowego kamieniołomu założonego pod koniec lat 40-tych ubiegłego wieku. Przed otwarciem labiryntu jaskiniowego system próżni podziemnych był prawie całkowicie wypełniony wodą i stanowił naturalną część zasobnego w wodę wodonośca krasowego. Otwarcie jaskini na etapie jej aktywnego formowania się oraz sztuczne jej odwodnienie stworzyło okazję do obserwacji (w trybie „przyśpieszonym”) przebiegu różnorakich procesów, towarzyszących przejściom jaskiń ze stadiów zawodnionych (freatycznych) do wadycznych i suchych. Badania mikrobiologiczne zmierzały do określenia liczebności mikroorganizmów (bakterii, grzybów i promieniowców) występujących w powietrzu jaskini w dwóch kontrastowych porach roku, latem i zimą. Badaniom mikrobiologicznym towarzyszyły pomiary mikroklimatyczne, które miały na celu ustalenie termicznych, wilgotnościowych i cyrkulacyjnych charakterystyk mikroklimatu jaskini. Ustalono prawidłowości występowania mikroorganizmów w przebiegu czasowym oraz przestrzennym (w obrębie jaskini), a także względną role czynników zewnętrznych i wewnętrznych (jaskiniowych) w kształtowaniu „obrazu” mikrobiologicznego powietrza jaskiniowego. Stabilność warunków mikroklimatycznych (ekologicznych) w jaskini w przebiegu rocznym pozwala wnioskować, że większość mikroorganizmów pochodzi z zewnętrzi trafia do jaskini w trakcie wymiany jej powietrza ze środowiskiem zewnętrznym. Nie mniej jednak, środowisko jaskiniowe nie pozostaje bierne, lecz różnicuje przestrzennie (w polu jaskiniowym) te zawartości, a w niektórych przypadkach również je warunkuje (w miejsca o znacznym antropogenicznym zanieczyszczeniu jaskini, sprzyjającym prawdopodobnie rozwojowi grzybów). Pomiary wykazały, że ogólna liczba badanych grup mikroorganizmów w powietrzu jaskini waha się w przebiegu rocznym w następujących przedziałach: bakterie 48-2630 jtk∙m-3 (rozrzut ponad 50-krotny), grzyby 80-3395 jtk∙m-3 (rozrzut ponad 40-krotny), promieniowce 5-51 jtk∙m-3 (rozrzut ponad 10-krotny). Średnie liczby zawartości mikroorganizmów w odniesieniu do całej jaskini wynoszą: bakterie 353 jtk∙m-3 grzyby 974 jtk∙m-3 i promieniowce 17 jtk∙m-3. Na ogół występuje prawidłowość wzrastania ich ilości w okresie ciepłym: dla bakterii 3-5 razy (48-764 jtk∙m-3 zimą i 175-2630 jtk∙m-3 latem), dla grzybów 4-5 razy (80-990 jtk∙m-3 zimą i 390-3395 jtk∙m-3 latem) i promieniowców 0-1 razy (0-51 jtk∙m-3 zimą i 5-55 jtk∙m-3 latem).
PL
Obserwowany w ostatnich latach wzrost zainteresowania mikrobiologiczną jakością powietrza niewątpliwie spowodowany jest pogorszeniem się warunków wewnątrz budynków użytkowych i mieszkalnych. Stwierdzono, że 80-90% czasu człowiek w ciągu swojego życia spędza w pomieszczeniach zamkniętych, dlatego zagadnienie jakości powietrza wewnętrznego staje się coraz bardziej istotne, szczególnie w budynkach użyteczności publicznej. Celem pracy była ocena zanieczyszczenia mikrobiologicznego powietrza wybranych pomieszczeń w budynkach Collegium Medicum im. L. Rydygiera w Bydgoszczy Uniwersytetu Mikołaja Kopernika w Toruniu (CM UMK). Badania jakości mikrobiologicznej powietrza przeprowadzono w wybranych pomieszczeniach budynków CM UMK, zlokalizowanych w kompleksie obiektów Szpitala Uniwersyteckiego nr l w Bydgoszczy przy ul. M. Skłodowskiej-Curie 9 (budynek I) oraz w kompleksie budynków przy ul. Jagiellońska 13-15 (budynek II). Ocenę czystości mikrobiologicznej powietrza przeprowadzono metodą sedymentacyjną Kocha, stosując czas ekspozycji wynoszący 20 minut. Podczas sedymentacji dokonywano pomiaru temperatury i wilgotności względnej powietrza. Badania mikrobiologiczne obejmowały oznaczenie ogólnej liczby bakterii i grzybów, liczby gronkowców mannitolo-dodatnich (w tym S. aureus) i man-nitolo-ujemnych, pałeczek laktozo-dodatnich i laktozo-ujemnych oraz promieniowców wyrażonej w j.t.k.xm-3 powietrza. Ogólna liczba bakterii w obu budynkach kształtowała się na poziomie 102-103 j.t.k.xm~3, a grzybów – 101 – 102 j.t.k.xm-3. Liczba promieniowców w powietrzu pomieszczeń, w których stwierdzono te drobnoustroje, mieściła się w granicach 101-102 j.t.k.xm-3. W badanym powietrzu wykazano także obecność gronkowców, w tym S. aureus, a w toaletach -pałeczek laktozo-dodatnich i laktozo-ujemnych. Poziom mikrobiologicznego zanieczyszczenia powietrza w wybranych pomieszczeniach budynków CM UMK może być różnie oceniony w zależności od przyjętych zaleceń. Nie przekracza on jednak wartości, które mogłyby wskazywać na narażenie zawodowe. Występowanie S. aureus, świadczy o obecności w badanym powietrzu mikroflory patogennej, w związku z czym jakość powietrza możemy uznać jedynie za zadowalającą.
EN
The increased of interest in microbial air quality, observed in recent years, is undoubtedly due to the deterioration of the conditions inside commercial buildings and residential buildings. It was found that people spend indoors 80-90% of their lifetime. For this reason, issue of indoor air quality is be-coming increasingly important, especially in public buildings. The aim of the study was to assess a microbial contamination of selected rooms air in the buildings belonging to the L. Rydygier Collegium Medicum in Bydgoszcz Nicolaus Copernicus University in Toruń. Research of air microbiological quality were conducted in selected rooms of buildings belonging to the L. Rydygier Collegium Medicum in Bydgoszcz Nicolaus Copernicus University in Toruń, located in the buildings complex of the University Hospital No. l in Bydgoszcz at M. Sklodowska-Curie 9 St. (building I) and in the buildings complex at Jagiellońska 13-15 St. (building II). The assessment of air microbiological purity was conducted with Koch's sedimentation method, using the exposure time of 20 min. The air temperature and relative humidity were measured during the sedimentation. Microbiological tests included determination of the total number of bacteria and fungi, number of mannitol-positive (including Staphylococcus aweus) and mannitol-negative staphylococci, Gram-negative rods and Actinomycetes expressed in c.f.u.xm-3 of air. The air temperature in the building I stood at 19.8°C - 23.1°C with relative humidity of 40.6% -49.7%, and in the building II ranged between 20.1°C - 22, 4°C with humidity 41.9% - 50.2%. The total number of bacteria in both buildings ranged between 102 - 103 c.f.u.xm-3, and the numer of fungi was on the level of 101 - 102 c.f.u.xm~3. The number of Actinomycetes in the air of rooms, in which these organ-lsms were found, also was within 101 - 102 c.f.u.xm-3. In the tested air the presence of staphylococci, including S. aureus was demonstrated, and in the toilets the lactose-positive and lactose-negative rods were also found. The level of air microbial pollution in selected rooms of buildings belonging to the L. Rydygier Collegium Medicum in Bydgoszcz can be differently evaluated depending on the adopted recommendations, but it did not exceed the value at which we can talk about occupational exposure. The presence of man-nitol-positive staphylococci, including S. aureus, indicates the presence of the pathogenic microflora in tested air, therefore, threrefore the air quality can only be considered as satisfactory.
3
Content available remote Mikrobiologiczne zanieczyszczenie powietrza w pomieszczeniach uczelni
PL
Celem badań była ocena stopnia zanieczyszczenia powietrza wewnętrznego pod względem mikrobiologicznym w salach dydaktycznych szkoły wyższej w zależności od pory roku i typu pomieszczenia. Próbki pobierano w trzech pomieszczeniach - auli wykładowej, sali ćwiczeniowej i holu oraz na zewnątrz budynku w okresie jesiennym, zimowym i wiosennym, rano i po południu (przed i po zajęciach dydaktycznych). Oznaczano ogólną liczbę bakterii psychrofilnych i mezofilnych, gronkowców mannitolododatnich promieniowców oraz grzybów. Wyniki podawano jako jednostki tworzące kolonie w nr (jtk/m3). Badania wykazały wyższą zawartość bakterii psychrofilnych niż mezofilnych, co wskazuje na stosunkowo wysoką sprawność systemu wentylacji. Zauważono zależności pomiędzy ilością i rodzajem mikroorganizmów a porami roku - najwięcej mikroorganizmów z grupy bakterii psychrofilnych, promieniowców i grzybów zaobserwowano wiosną i jesienią, najmniej zimą. Dobowa zmienność zawartości mikroorganizmów w powietrzu zależała od charakteru badanego pomieszczenia. Najmniej zanieczyszczone było powietrze w sali ćwiczeniowej, gdyż w sali tej sprawność wentylacji była wyższa niż w innych badanych pomieszczeniach. Duży wpływ na wysokie stężenia mikroorganizmów w godzinach porannych w sali wykładowej miało przeprowadzane tam sprzątanie. Najwyższe zanieczyszczenie stwierdzono w holu. Nie odnotowano przekroczenia zalecanych przez Komisję Europejską wartości stężeń bakterii w powietrzu dla pomieszczeń wewnętrznych. Stwierdzono przekroczenie bardzo restrykcyjnych zaleceń WHO w stosunku do stężeń mieszaniny grzybów w powietrzu wewnętrznym.
EN
Most of our life is spent indoors and therefore indoor air may present a greater risk to human health than exposure to atmospheric air contaminants. Among microorganisms present in indoor air there are bacteria, fungi and viruses which can be allergic, pathogenic and/or cause immunotoxic effects. The aim of the investigation was to examine the microbiological pollution of indoor air in university rooms depending on a season of the year and a type of a room. The research was carried out in autumn, winter and spring. Three types of rooms were selected: a big lecture hall, a small exercise room and an entrance hall. Outdoor air was investigated as well. For the purpose of air sampling, the impaction method was employed and MAS 100 Eco sampler, operating on the principle of the Andersen air sampler (corresponding to its 5th stage) was used. Air samples were taken in 2 series - early in the morning and late afternoon (before and after lectures). Total numbers of psychrophilic and mesophilic bacteria, mannitol-positive staphylococci, actinomycetes and fungi were determined. The cultivation method was applied and therefore only cultivable microorganisms, capable of growing on solid media, were detected. Results were presented as colony forming units in m3 (CFU/m3). The proposition of a new Polish Standard for microbiological quality of atmospheric air was used as a criterion for assessing microbiological pollution of outdoor air. guidelines of WHO and CEC - for indoor air. The investigations proved higher concentrations of psychrophilic than mesophilic bacteria in indoor air, which suggests that the ventilation system works properly and effectively. A direct correlation between a season of the year and the number and type of microorganisms in indoor air was found - higher amounts of psychrophilic bacteria, actinomycetes and fungi were observed in spring and autumn than in winter. The lowest pollution was found in the small exercise room - number of microorganisms was lower in the morning and clearly higher in the afternoon. In the lecture hall air quality in the morning was strongly affected by cleaning operations which increased concentrations of microorganisms in the air. The indoor air of lecture and exercise rooms was generally clean and numbers of bacteria did not exceed the average levels given in the guidelines. The total numbers of microorganisms (as CFU/m3) ranged between 10 and 1030 for mesophilic bacteria, 50 and 1930 for psychrophilic bacteria, 0 and 10 for staphylococci. 0 and 6 for actinomycetes, 0 and 232 for fungi. Relatively higher microbiological pollution was found in the entrance hall. The total numbers of microorganisms ranged between 380 and 1910 for mesophilic bacteria, 680 and 4460 for psychrophilic bacteria, 1 and 16 for staphylococci, 0 and 15 for actinomycetes, 13 and 762 for fungi. The number of fungi exceeded the WHO guidelines for mixture of species in indoor air. The outdoor air was generally polluted at low level.
PL
Przeprowadzono analizę mikroorganizmów obecnych w aerozolach emitowanych przez poszczególne podzespoły układu technologicznego miejskiej oczyszczalni ścieków "Łyna" w Olsztynie. Badania terenowe metodą sedymentacyjną przeprowadzono w trzech seriach pomiarowych. Punkty poboru prób wyznaczono, uwzględniając wyniki obserwacji meteorologicznych dotyczących kierunku i prędkości wiatru. Oznaczenia mikrobiologiczne obejmowały: bakterie heterotroficzne, hemolizujące, gronkowce mannitolododatnie i mannitoloujemne, bakterie z rodziny Enterobacteriaceae, z rodzaju Pseudomonas, promieniowce, grzyby drożdżoidalne oraz pleśnie. Liczbę drobnoustrojów, zwłaszcza hemolizujących, można uznać za zagrażającą zdrowiu, szczególnie w aerozolach generowanych z komór napowietrzania oraz przy węźle zbierającym osady do recylkulacji z osadników wtórnych.
EN
This paper presents the results of studies on pollution and the sanitary-bacteriological conditions of the aerosols emitted from a municipal wastewater treatment plant (flow rate about 60 000 m3/day). Field studies by sedimentation method were conducted in three series. Each time sample points were chosen after taking into consideration meteorological observation results: direction and speed of the wind. Microbiological analyses comprised the following: TVC, hemolizing bacteria, Enterobacteriaceae family, Staphylococcus and Pseudomonas strains, actinomycetales and fungi (yeasts and moulds) amounts as cfu/m3. Aeration tanks and recirculated sludge open channel arę the major sources of the airborne bacteria. The number of the hemolyzing bacteria above 50 cfu/m3 indicates that air was polluted by pathogens around all technological objects of wastewater treatment plant.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.