The paper presents the phenomenon of thermal bridges caused by air infiltration. The problem of poor air tightness is very common in the former Eastern Bloc countries. The laboratory investigation was set up to recognize the impact of air infiltration on heat flux through the building envelope. The frame wall model insulated with loose mineral wool was investigated in non-isothermal climatic chamber. As a result of cold air infiltration, surfaces of gaps and areas adjacent to them were cooled, which is illustrated on temperature profiles. The forty minutes infiltration of 0o C air resulted as a 3.5o C cooling of gap area. The thermal simulation in Delphin confirmed the laboratory results.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The paper presents the phenomenon of air thermal bridges. The results of thermal simulation are presented. The impact of air infiltration on the surface temperature adjacent to air thermal bridges is discussed.
PL
W artykule przedstawiono zjawisko powietrznych mostków cieplnych. Przedstawiono wyniki symulacji cieplnych. Omówiono wpływ infiltracji powietrza na zmiany pola temperatury znajdującego się w pobliżu powietrznego mostka cieplnego.