Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 33

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  aerosols
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
One of today's most important environmental problems is air pollution augmentation. Air pollution is getting worse over time and hurts human health. For the current study, various polar orbiting satellites were utilized to collect data on PM2.5, SO2, AOD, CO, and ozone over Pakistan between January 2005 and December 2021. According to the spatial distribution results, these characteristics have high values throughout central Punjab, western Baluchistan, central Sindh, and Khyber Pakhtunkhwa. The seasonal variation in PM2.5, SO2, AOD, CO, and ozone was calculated using monthly data. The greatest value for PM2 5 is 8.7 X 10-8 kg/m3 during the monsoon season, while the highest value for SO2 is 1.4 X 10-5 kg/m2 during the winter. Over Punjab, Sindh, Baluchistan, KPK, and Gilgit, AOD was between 0.7 and > 1.0, CO was 127.2 ppb, and ozone was 330.7 DU. Furthermore, we create correlation maps of AOD, CO, SO2, PM2.5, and ozone and evaluate their relationship of high and low values across Pakistan. We looked into the 0.99 correlation between AOD and PM2.5, the strongest ever recorded. Despite this, we look at time series graphs to show the rising and falling pattern of these parameters from January 2005 to December 2021. We also used tables to determine the relative change in Multan, Lahore, Karachi, Peshawar, Quetta, Rawalpindi, Faisalabad, Hyderabad, Gujranwala, and Abbottabad in Pakistan from January 2005 to December 2021.
2
PL
Stosowanie nanomateriałów może stanowić zagrożenie dla ludzkiego zdrowia. Z punktu widzenia zarządzania ryzykiem ważne jest posiadanie informacji ilościowych na temat stężenia aerozoli nanoobiektów w otaczającym środowisku. Z uwagi na wysoką cenę urządzeń klasy laboratoryjnej typu liczniki kondensacyjne lub liczniki elektrometryczne są one stosowane tylko do okresowych pomiarów stężenia liczbowego nanoobiektów. W związku z tym rośnie zapotrzebowanie na urządzenia, które umożliwiałoby monitorowanie stężenia aerozoli nanoobiektów, a jednocześnie byłyby na tyle tanie, żeby można je było instalować wszędzie tam, gdzie używa się nanomateriałów i gdzie aerozole nanobiektów mogą powstawać w sposób spontaniczny. W artykule przedstawiono metody i rozwiązania techniczne pozwalające na wykonanie bezpośredniego pomiaru parametrów charakterystycznych dla nanoobiektów znajdujących się w powietrzu w obrębie stanowisk pracy, w tym opracowany przez autorów w ramach V etapu programu wieloletniego „Poprawa bezpieczeństwa i warunków pracy” niskokosztowy miernik aerozoli nanoobiektów. Zaprezentowano wyniki badań weryfikujących poprawność działania prototypu tego miernika w środowisku pracy związanym z obszarem nanotechnologii.
EN
The use of nanomaterials may pose a risk to human health. For risk management, it is important to have quantitative information on the concentration of nano-object aerosols in the surrounding environment. Due to the high price of laboratory-class devices, such as condensation counters or electrometric counters, they are used only for periodic measurements of the number concentration of nano-objects. Currently, there is a growing need for devices capable of monitoring the concentration of nano-object aerosols that are cheap enough to be installed where nanomaterials are used or aerosols can be spontaneously generated. The article presents methods and technical solutions for direct measurement of parameters characteristic of nano-objects workplaces in the air. One of the solutions is the prototype developed by the authors within the scope of the 5th stage of the National Programme “Improvement of safety and working conditions” a low-cost nano-object aerosol meter. The results of tests verifying the correct operation of the prototype of this meter in the work environment related to the area of nanotechnology are presented.
3
Content available remote Koloidy w życiu codziennym
PL
Koloidy, czyli układy złożone z małych cząsteczek rozproszonych w medium, są obecne w wielu aspektach naszego codziennego życia. Jednym z najczęstszych zastosowań koloidów jest żywność. Wiele produktów spożywczych, takich jak mleko, ser i lody, to koloidy. Obecność koloidów w tych produktach może wpływać na ich teksturę, konsystencję i smak. Ponadto są one również stosowane w produkcji wielu produktów kosmetycznych i środków higieny osobistej, w tym balsamów, szamponów i past do zębów. Koloidy mogą pomóc w stabilizacji tych produktów, zapobiegając ich rozdzieleniu i zapewniając jednorodność [1]. Koloidy odgrywają również istotną rolę w miejscach o których większość z nas nie zdaje sobie sprawy, a które mają znaczny wpływ na nasze życie. Na przykład aerozole, w tym dezodoranty czy też leki w postaci sprayu, są koloidami. Układy tego typu nie są jednak tylko sztucznym tworem człowieka. Występują one również naturalnie, w postaci mgły dymu lub chmur. Dzięki koloidom możemy potwierdzić istnienie atomów, a także cieszyć się pięknym błękitnym niebem [2]. Podsumowując, koloidy są wszechobecne w naszym codziennym życiu i mają szeroki zakres zastosowań. Ich obecność znacząco wpływa nie tylko na właściwości i działanie różnych produktów, ale również na cały otaczający nas świat.
EN
Colloids, which are complex systems of small molecules dispersed in a medium, are present in many aspects of our daily lives. One of the most common applications of colloids is in food. Many food products, such as milk, cheese and ice cream, are colloidal suspensions. The presence of colloids in these products can affect their texture, consistency and taste. In addition, they are also used in the production of many cosmetic and personal care products, including lotions, shampoos and toothpastes. Colloids can help stabilize these products, preventing separation and ensuring homogeneity. [1] Colloids also play an important role in areas that most of us are unaware of, but which have a significant impact on our lives. For example, aerosols, including deodorants or drug sprays, are colloids. However, systems of this type are not just an artificial creation of man. They also occur naturally, in the form of smoke mist or clouds. Thanks to colloids, we can confirm the existence of atoms, and enjoy the beautiful blue sky. [2] In summary, colloids are ubiquitous in our daily lives and have a wide range of applications. Their presence significantly affects not only the properties and performance of various products, but also the entire world around us.
EN
Aerosols play a crucial role in climate change by providing a radiation balance between the Earth and atmosphere. In the present study, aerosol sources and sinks have been identified over African region using the Modern-Era Retrospective analysis for Research and Applications, Version 2 reanalysis data from 1985 to 2015. The study mainly focused on climatological and seasonal changes in aerosol distribution and concentrations over African continent and their impact on east African rainfall. Western Africa shows high concentrations of aerosol optical depth (AOD) of greater than 0.3 due to localized pressure changes and diverging winds from the Sahara desert. The highest amount of AOD ( ̴0.8) has been observed in winter season due to strong surface winds and high production of sea salt. When temperature is high in summer season ( ̴306 K), it has been observed that aerosol area distribution increases but their concentration decreases. The highest amount of rainfall ( ̴295 mm) was recorded in the winter season between 1997 and 1998. A strong inverse relationship was observed between aerosol and the east African rainfall. In 2015, the lowest amount of rainfall was observed in the summer season ̴100 mm due to the observed high presence of aerosols. On average, the correlation coefficient between aerosols and precipitation over east Africa has been found to be negative. The increase in rainfall is associated with an increase in relative humidity. However, during the east African monsoon season, the presence of some aerosols cause the development of convective clouds and hence more rainfall.
5
Content available remote Atmospheric in situ gamma-ray spectrometry for precipitation investigation
EN
The underwater gamma-ray spectrometer GeoMAREA was utilized for in situ continuous monitoring of radon progenies in the atmosphere near the city of Anavyssos, Attica, Greece, during the period from 1 November 2017 until 1 April 2018. The acquired spectra before and during rainfalls were used to derive rainwater’s spectra revealing that the major contributors to the observed photo-peaks are the progenies of 222Rn (214Pb, 214Bi). The total counting rate of the spectra and the counting rate of the net areas of 352 keV and 609 keV photo-peaks (214Pb and 214Bi, respectively) proved to be effective parameters for rainfall identification and investigation. Statistical analysis did not reveal a significant association between radon progenies and temperature, pressure, humidity and dew point during rainfalls or dry meteorological conditions. However, preferable wind directions for rainwater rich in radon progenies revealed the impact of the atmospheric masses trajectories before a precipitation event. According to HYSPLIT modelling of selected rainfall events, air masses that pass over terrestrial areas at low altitudes (< 1500 m above ground level) 48 h before the event result in rainwater enriched in radon progenies. On contrary, air masses that pass before an event over terrestrial areas at higher altitudes (> 3000 m above ground level) result in rainwater of low radon progenies concentration. Overall, the method was considered promising for continuous in situ measurements of radon progenies in the atmosphere and may extend the use of radon as a tracer for studies related to climate investigation.
EN
The paper highlights selected problems of physical chemistry and dynamics of colloidal systems indispensable for the understanding and optimization of drug delivery by inhalation. Besides describing the fundamental aspects of aerosol flow and deposition in the respiratory system, some problems related to particle or droplet generation in the inhalers are discussed. In particular, the influence of liquid properties on aerosol formation in different nebulizers is demonstrated as a critical factor in successful aerosol therapy. The paper also addresses interactions between inhaled drug particles and bronchial mucus or the pulmonary surfactant, indicating another broad field of colloid and interface science application in medicine.
EN
Four years of observations of radon, meteorology and atmospheric pollution was used to demonstrate the efficacy of combined diurnal and synoptic timescale radon-based stability classification schemes in relating atmospheric mixing state to urban air quality in Zgierz, Central Poland. Nocturnal radon measurements were used to identify and remove periods of non-stationary synoptic behaviour (13–18% of each season) and classify the remaining data into five mixing states, including persistent temperature inversion (PTI) conditions, and non-PTI conditions with nocturnal conditions ranging from well mixed to stable. Mixing state classifications were performed completely independently of site meteorological measurements. World Health Organization guideline values for daily PM2.5/PM10 were exceeded only under strong PTI conditions (3–15% of non-summer months) or often under non-PTI stable nocturnal conditions (14–20% of all months), when minimum nocturnal mean wind speeds were also recorded. In non-summer months, diurnal amplitudes of NO (CO) increased by the factors of 2–12 (3–7) from well-mixed nocturnal conditions to PTI conditions, with peak concentrations occurring in the morning/evening commuting periods. Analysis of observations within radon-derived atmospheric mixing ‘class types’ was carried out to substantially clarify relationships between meteorological and air quality parameters (e.g. wind speed vs. PM2.5 concentration, and atmospheric mixing depth vs. PM10 concentration).
8
Content available Air Quality in a Brewery Bottling Plant
PL
Przedstawione wyniki badań dotyczą jakości powietrza w rozlewni piwa. W trakcie normalnej pracy rozlewni mierzone były stężenia masowe i koncentracje ilościowe cząstek aerozolowych, stężenia bakterii i grzybów oraz stężenia związków karbonylowych w powietrzu. Stężenia aerozoli określano w sposób ciągły metodami spektrometrii optycznej. Zanieczyszczenia biologiczne oznaczano metodą sedymentacyjną wykorzystując płytki Petriego z odpowiednimi pożywkami. Stężenia związków karbonylowych w powietrzu określano metodą pasywną używając dozymetrów Radiello. Przy oznaczaniu stężeń zanieczyszczeń biologicznych i związków karbonylowych wykonano odpowiednio dwie i trzy serie pomiarowe w dwóch miejscach rozlewni piwa. Pomimo zautomatyzowania procesu rozlewania piwa do butelek zaobserwowano okresowe znaczące wzrosty stężeń mierzonych zanieczyszczeń. Średnie stężenia masowe wszystkich mierzonych frakcji cząstek aerozolowych miały podobne wartości i wynosiły ok. 0,2 mg/3. Maksymalnie ok. 5-cio krotne wzrosty koncentracji masowych cząstek obserwowano w nieregularnych odstępach czasu. Największe koncentracje ilościowe zmierzono dla cząstek drobnych. Średnie koncentracje cząstek o wielkościach 0,3-0,5 µm i 0,5-1 µm miały odpowiednio wartości 847 i 93 cząstki/c3. W przypadku zanieczyszczeń biologicznych średnie stężenie bakterii w powietrzu w rozlewni piwa wynosiło 1441 JTK/3, a średnie stężenie grzybów 557 JTK/3. Wartości te są niższe niż proponowane dopuszczalne poziomy stężeń bakterii i grzybów w budynkach użyteczności publicznej. Średnie stężenia mierzonych związków karbonylowych również nie przekraczały wartości, które są dopuszczalnych w środowisku pracy. Oprócz formaldehydu, którego okresowe stężenia wzrastały do prawie 800 µg/3 stężenia innych związków były w zakresie akceptowalnym dla pomieszczeń przeznaczonych na pobyt ludzi. Nieco wyższe stężenia niektórych związków karbonylowych odnotowano w punkcie pomiarowym w pobliży myjni butelek. Przedstawione wyniki wskazują, że istnieje potencjalne zagrożenie dla zdrowia pracowników rozlewni piwa związane z okresowymi wzrostami stężeń mierzonych zanieczyszczeń.
EN
The determination of the level of pollutants and reciprocal relations “outside-inside” forms an important component in the study involving assessment and control of indoor air quality. This paper reports the results of a study with regard to the mass concentration of PM10 determined concurrently in the outdoor air surrounding a university building and inside the lecture rooms in it. The research project was undertaken in the cold season and registration included 83 independent observations with the duration of 90 minutes. The research applied a reference method involving measurements of PM10 mass concentration using gravimetric technique. The results were analyzed by application of non-parametric tests. For the purposes of classification of variables and assessment of the role of the specific variables, the analysis was based on the use of principal components. It was indicated that the mass concentration of particulate matter in the lecture rooms dśs not differ from the levels measured at the same time in the air surrounding the building only during the periods corresponding to periodic room ventilation. It was also found that the design and usage of the buildings, as well as the number and activity of humans determine the aerosanitary conditions in the enclosed spaces formed by the lecture rooms. It was observed that the mass concentration of particulate matter in the rooms is higher in the cold season. A statement was made that design solutions need to be implemented with the purpose of using intelligent ventilation systems.
PL
Określenie udziału źródeł zanieczyszczeń oraz wzajemnej relacji „outside-inside” jest istotnym problemem w szacowaniu i kontroli jakości powietrza wewnętrznego. Artykuł przedstawia wyniki badań nad stężeniem masowym PM10 określonym jednocześnie w okalającym budynek powietrzu zewnętrznym oraz w salach dydaktycznych uczelni wyższej. Projekt badawczy przeprowadzono w sezonie chłodnym, rejestrując 84 niezależne, 90-minutowe obserwacje. W badaniach wykorzystano, opartą na grawimetrii, referencyjną metodę pomiaru stężenia masowego PM10. Rezultaty badań przeanalizowano przy użyciu testów nieparametrycznych. W badaniach, celem klasyfikacji zmiennych i oszacowania odpowiedzialności poszczególnych czynników, posłużono się analizą składowych głównych. Wykazano, że wartości stężenia masowego pyłu zmierzonego w salach dydaktycznych nie różnią się od poziomów określonych jednocześnie w okalającym budynek powietrzu zewnętrznym wyłącznie podczas okresowego wietrzenia pomieszczeń. Stwierdzono, że konstrukcja oraz sposób użytkowania budynku a także liczba i aktywność osób w znaczący sposób determinują warunki aerosanitarne w pomieszczeniach zamkniętych. Wykazano, że w sezonie chłodnym stężenie masowe pyłu zawieszonego jest wyższe w pomieszczeniach. Złożono postulat przyjęcia rozwiązań polegających na implementacji inteligentnych systemów wentylacyjnych.
PL
Przedstawiono wyniki badań półmasek filtrujących wytworzonych na bazie opracowanych materiałów filtracyjnych z polipropylenu i poliwęglanu zawierających modyfikator w postaci perlitu. Wytworzone półmaski filtrujące poddano badaniom w zakresie penetracji aerozoli testowych (chlorek sodu i mgła oleju parafinowego) oraz oporu oddychania (w fazie wdechu i wydechu) wg standardowej metodyki badań przedstawionej w normach przedmiotowych oraz niestandardowej metodyki badań dotyczącej penetracji wobec nanoaerozoli chlorku sodu. Stwierdzono, że zarówno półmaska na bazie polipropylenu z modyfikatorem, jak i półmaska na bazie poliwęglanu z modyfikatorem zapewniają dwukrotnie wyższą ochronę niż standardowe półmaski filtrujące zawierające materiały filtrujące stosowane do produkcji półmasek filtrujących o najwyższej, trzeciej klasie ochronnej.
EN
Two filtering half masks with perlite-modified polypropylene and polycarbonate nonwoven layers were constructed and studied for penetration of NaCl and paraffin oil mist nanoparticles-containing aerosols. The half masks were more efficient than conventional half masks without perlite-modified nonwoven layers.
EN
Knowledge about aerosol cloud-mediated processes is important for judging climate change in Europe during recent decades. Here, some observational evidence for anthropogenic influences is described and discussed. The emphasis is laid on the effects of the large emissions of sulphur dioxide and particulate matter during the 1980s in Europe and the subsequent strong decrease in the 1990s. In addition, an analysis of the dependence of aerosol cloud-mediated processes on atmospheric circulation patterns (Grosswetterlagen) is presented.
EN
A new bioaerosol sampler developed for extremely low concentration levels of airborne bacteria and fungi has been described. The results of the pilot study of the prototype of this new sampler are also presented in this paper. During the field studies the concentration levels of bacterial and fungal aerosols were obtained using simultaneously the new sampler and the reference cascade Andersen 6-stage impactor, as well as the Air Ideal sampler. Although only a preliminary study has been carried out, the obtained data indicated that the assumed designing parameters for the new sampler are suitable and guarantee high collection efficiency of this instrument.
EN
Exposure to bioaerosols at various stages of waste management system (collection, transfer and disposal) has been evaluated by recording of the bacterial and fungal concentrations in the air around these facilities. Regardless of the season, the total bacteria and total fungi were detected for all sampies, whereas the fungal genera were not. The bioaerosol concentrations measured in the waste collection bins were significantly higher than those of the transfer station and landfill site. The mean microbial concentrations at wastes container bins and in-operation trench exceeded the Iran outdoor bioaerosol guidelines (850 CFU/m3), thus suggesting the need for remedial action regarding microorganisms, in order to reduce the exposure at the wastes management system.
14
Content available remote Dynamic Changes in the Filtration Efficiency of Cooling Oil Filter Media
EN
Metal-working fluids are used in machining and grinding operations to cool the tool and work piece, reduce the friction between the tool and work, improve the surface integrity of the work piece and increase tool life and productivity. The removal of oil mists from air streams is very important in a wide range of industrial applications, and filtration is by far the most effective method for this task. This article presents the results of changes in the fractional efficiency of the filtration process of the test aerosol through multistage filtering systems of different thickness and miscellaneous structural characteristics in the cross-section. The efficiency of filtration through multistage filtering systems was tested with the use of DEHS and DOP aerosol. Research results indicate the functional dependence of filtering properties on the structural parameters of nonwovens and machining process parameters, as well as on the physicochemical parameters of liquid aerosols. This may be of essential importance in forecasting the use of multistage filtering systems as filtering media for a given process of liquid aerosol filtration, given the maintenance of the most advantageous filtration conditions, i.e. high efficiency of filtration and low resistance of aerosol flow.
PL
W procesach obróbki skrawania i szlifowania chłodziwa olejowe znajdują szerokie zastosowanie do schładzania i zmniejszania tarcia między narzędziem skrawającym i obrabianym przedmiotem, poprawy jakości obrabianych powierzchni i przedłużania żywotności narzędzia skrawającego. W wielu zastosowaniach w przemyśle podstawowym zadaniem jest usunięcie mgły olejowej z powietrza. Filtracja powietrza jest zdecydowanie najskuteczniejszą metodą realizacji tego zadania. W artykule przedstawiono wyniki zmian sprawności frakcyjnej procesu filtracji aerozoli testowych w wielostopniowych układach filtracji o różnej grubości i strukturze w przekroju poprzecznym. Badanie sprawności filtracji przez wielostopniowe układy filtracji było wykonywane testem aerozolu DEHS i DOP. Wyniki badań wskazują na funkcyjną zależność właściwości filtracyjnych od parametrów strukturalnych włóknin, parametrów procesowych obróbki mechanicznej oraz parametrów fizykochemicznych aerozoli cieczy. Może to mieć istotne znaczenie podczas prognozowania zastosowania wielostopniowych układów włóknin jako materiały filtracyjne dla danego procesu filtracji aerozoli cieczy, przy zachowaniu najkorzystniejszych warunków filtracji, tzn. wysokiej sprawności filtracji i niskich oporów przepływu aerozolu.
PL
W artykule przedstawiono dwubarwny LIDAR rozproszeniowy, który został opracowany w Instytucie Optoelektroniki w Wojskowej Akademii Technicznej. LIDAR ten przeznaczony jest do zdalnej detekcji aerozoli naturalnych oraz sztucznych, zarówno biologicznych, jak i chemicznych. W pracy omówiono budowę LIDARA, jego podstawowe parametry oraz zaprezentowano wyniki badań laboratoryjnych i terenowych z jego zastosowaniem.
EN
In the article, two-wavelength backscattering LIDAR is presented. LIDAR was worked out and constructed at the Institute of Optoelectronics of the Military University of Technology. This LIDAR is destined for remote sensing of biological and chemical aerosols, both natural and antropoghenic ones. In the work, one discussed the construction of LIDAR and typical parameters and first results obtained with its application.
PL
Praca dotyczy analizy procesu porywania i deagregacji cząstek proszku w warunkach odpowiadających działaniu inhalatorów proszkowych (tzw. DPI), stosowanych do dawkowania leków metodą wziewną. Badano resuspensję cząstek modelowego proszku w komorze cylindrycznej (13 mm), w obecności elementów zaburzających pole przepływu powietrza w obszarze porywania. Stwierdzono istotny wzrost sprawności resuspensji proszku w porównaniu z układem niezawierającym elementów zaburzających. Zaobserwowano również poprawę deagregacji cząstek aerozolowych w układzie z zaburzeniem przepływu, uzyskując zmniejszenie wartości mediany masowej z około 12 do około 8,5 , a więc osiągając wyższy udział respirabilnej frakcji proszku. Zmierzony wzrost oporów przepływu powietrza, związany z zastosowaniem zaproponowanych w pracy elementów zaburzających, jest stosunkowo niski, co pozwala na zastosowanie tego typu rozwiązań w komorach porywania proszków rzeczywistych inhalatorów medycznych.
EN
The resuspension and deaggregation of a test powder was studied in cylindrical chamber ( 13 mm) in the presence of elements used for flow dissarangement in the vicinity of the powder layer. A noticeable increase in the resuspension efficiency was observed in the case of the disturbed flow together with an improvement in the particle deaggreagation (a drop in MMD from approx. 12 to approx. 8.5 ). The increase of flow resistance associated with the use of flow disarrangement is reasonably Iow, allowing use of the proposed systems in real inhalers.
EN
A laboratory study was carried out to investigate the single particle soil dust using aerosol time-of-flight mass spectrometry. The presence of crustal elements is observed in the mass spectra of individual particles. Potassium and iron constitute the two most commonly detected cations. Other common cations observed in the mass spectra of soil particles include sodium and magnesium. According to a large number of single aerosol diameters, we obtained the size distribution. Peaks in the positive ion mass spectra enable us to identify individual dust particles in atmospheric samples and track chemically distinct dust particles in the atmosphere using aerosol time-of-flight mass spectrometry.
PL
W niniejszej pracy przedstawiono wyniki badań zawartości aerosoli w atmosferze obszaru zurbanizowanego. Zawartość aerosoli wyznaczano metodą, pośredną, na podstawie pomiarów natężenia promieniowania słonecznego bezpośredniego w całym zakresie spektrum. Stopień zawartości erosoli w atmosferze obliczano poprzez eliminację wpływu pozostałych czynników pochłaniających i rozpraszających, wykorzystując wybrany model transmisji promieniowania słonecz- ego bezpośredniego. Użyto współczynnika Angstroma jako liczbowej miary zawartości aerosoli w atmosferze. Dokonano nalizy wpływu kierunku i prędkości wiatru na zawartość aerozIi w rejonie miasta Opola. Wykorzystano wyniki pomiarów własnych z okresu ostatnich 14 lat.
EN
The results of investigation of the aerosol content in the atmosphere of urban region are presented. The aerosol content was determined using indirect method based on meas- urements of broadband direct solar radiation intensity. The aerosol content index was calculated by elimination of influence of all other attenuating factors, using selected model of broadband transmission of direct solar beam in the atmosphere. Angstrom's turbidity coefficient was used as aerosol content index. An analysis of influence of such meteorological parameters as wind direction and wind velocity on the aerosol content was performed in the Opole location. The presented results have been obtained on the bases of fourteen years of measurements.
PL
Wciąż istnieją zagrożenia, w odniesieniu do których brak jest zdefiniowanych wymagań oraz ustalonych metod badań sprzętu ochrony układu oddechowego (SOUO). W artykule przedstawiono opracowaną metodykę badań elementów filtracyjnych służących do ochrony układu oddechowego przed aerozolami promieniotwórczymi. Otrzymane wyniki badań wskazują na konieczność wprowadzenia dodatkowych testów SOUO przewidzianego do ochrony przed takimi aerozolami.
EN
There are still hazards for which there are no test methods or requirements defined for respiratory protective devices (RPD). This article presents a test method that has been worked out for filtration elements against radioactive aerosols. Test results show that additional test methods and requirements should be introduced for RPD intended for use against such aerosols.
EN
Aerosol particle size distribution and chemical properties are important in studies related to human health and climate. The present study describes an analysis of aerosol mass loading, Aerosol Optical Depth (AOD), black carbon aerosol mass concentration and carbon monoxide over tropical urban region of Hyderabad, India, during March 2006, coinciding with active forest fires season over India. Aerosol optical depth, particulate matter mass loading and carbon monoxide were observed to be high on days with air mass coming from north of the study area. Spatial occurrence of forest fires was analysed using MODIS daytime data and DMSP-OLS nighttime data sets. Aerosol optical depth measured using Micro-tops–II sunphotometer correlated well with MODIS derived AOD values. Results of the study suggested that synoptic meteorological conditions play an important role in the observed aerosol properties over the study area during the forest fire season.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.