Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  aerosol size distribution
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
There are two approaches to the estimation of radon dose. One of them based on the ICRP 65 using a single dose conversion factor, called conversion convention, is derived from the results of the epidemiological studies of uranium miners. The second approach (ICRP 66) recommends the usage of dosimetric models for inhalation of airborne radionuc1ides. This method requires the full radon progeny size distribution (1-1000 nm) beside the alpha potential energy concentration. By means of our Radon Progeny Particle Size Spectrometer both of these quantities were estimated at 4 workplaces and at 4 homes. The measurements were conducted in natural and high level of the aerosol conditions. Ratios of doses estimated by the dosimetric model and with the use ofthe conversion coefficient range from 0.6 to 1.9 at workplaces and from 0.6 to 2.6 at homes.
PL
W ochronie radiologicznej stosuje się dwie metody oceny efektywnej dawki wynikającej z inhalacji krótkożyciowych produktów rozpadu radonu. Pierwsza z nich (ICRP 65) polega na zastosowaniu stałego współczynnika konwersji stężenia energii potencjalnej alfa (PAEC) na dawkę, oszacowanego na podstawie badań epidemiologicznych górników uranowych. Druga metoda, zalecana w ICRP 66, wykorzystuje dozymetryczne modele inhalacji radionuklidów. Według niej do oceny dawki niezbędna jest znajomość nie tylko PAEC, ale również rozkładu średnic cząstek (1-1000 nm) - nośników produktów rozpadu radonu. Za pomocą Spektrometru Średnic Pochodnych Radonu wykonano pomiary obu tych wielkości w 4 miejscach pracy oraz w 4 domach mieszkalnych. Pomiary były wykonywane w warunkach naturalnego oraz dużego stężenia aerozoli. Stosunki dawek otrzymanych metodą modelu dozymetrycznego do dawek obliczonych za pomocą stałego współczynnika konwersji mieszczą się w zakresie od 0,6 do 1,9 dla miejsc pracy oraz od 0,6 do 2,6 dla domów mieszkalnych.
EN
The spectral aerosol optical thicknesses (SAOT) of vertical air columns were measured by a ground-based four-channel Linke's sunradiometer at Belsk Geophysical Observatory during five years: 1993-1998. Results of measurements in the form of mean monthly values are presented. The aerosol size distribution retrieved from SAOT by means of the Randomized Minimization Search Technique algorithm and bi-modal log-normal size-distribution model is also demonstrated. The results of measurements confirm the well-known regularity that the average dependence of atmospheric extinction on wavelengths in visible range is described by exponential Angstrom's formula with exponent 1.3 š 0.6. Moreover, it is pointed out that in a few cases, in atmosphere column over Belsk Geophysical Observatory there dominated big particles, of 0.6-1.2 mim radii. However, in most cases, small, 0.15-0.30 mim particles dominated which had its impact on the average distribution during five years. It is estimated that in this period the average monthly values of the volume concentration, the mean modal radius, and the effective radius of the aerosol particles have been decreasing, but the particle number density bas increased. The "cleaning of the atmosphere" was observed, i.e., aerosol underwent transformation towards smaller particles and a decrease of particle volume concentration, proportional to the weight concentration.
first rewind previous Strona / 1 next fast forward last